Musa A. Ayashi

Musa A. Ayashi

Auto-generated profile, based on publicly available information

Musa A. Ayashi

Main Laboratory and Blood Bank Medical and Molecular Microbiology Laboratory Jazan Health Cluster Jazan Saudi Arabia

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Journal of Parasitology Research
Verified
Journal Article
Open access
AMAhmed A. Muyidi
Ahmed A. Muyidi
MAMusa A. Ayashi
Musa A. Ayashi
Majed H. WakidMajed H. Wakid
Majed H. Wakid
MAMaimonah S. Alghanmi
Maimonah S. Alghanmi
FBFadi Mohammad Baakdah
Fadi Mohammad Baakdah
TBThamer M. Brek
Thamer M. Brek
Background: Malaria is a deadly vector‐borne parasitic disease spread by the bite of an infective female Anopheles mosquito. In routine malaria diagnosis, microscopic examination is generally regarded as the gold standard. Our study sought to evaluate the diagnostic precision of two commercially accessible quantitative PCR (qPCR) kits, in contrast to light microscopy and nested multiplex PCR (NM‐PCR). Methods: This cross‐sectional study in southwest Saudi Arabia included 92 febrile patients meeting the inclusion criteria. Detection of Plasmodium species used light microscopy, NM‐PCR, and qPCR kits (RealStar and Viasure). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and receiver operating characteristic (ROC) curves were calculated. Statistical analysis was performed using SPSS v25, with significance set at p ≤ 0.05. Results: Light microscopy detected 92.4% of cases, NM‐PCR detected 73.9%, and RealStar and Viasure detected 92.4% and 95.7%, respectively. Viasure showed the highest sensitivity (97.6%) and NPV (50%), while NM‐PCR had superior specificity (71.4%). For species identification, Plasmodium falciparum detection was highest with RealStar (85%). Mixed infections were better identified by Viasure (34.6%). RealStar excelled in Plasmodium vivax detection (area under the curve [AUC] = 90 % ). qPCR detected low parasitemia levels missed by microscopy. Conclusions: The qPCR kits, particularly Viasure, demonstrated superior sensitivity for detecting Plasmodium species and identifying mixed infections compared to light microscopy and NM‐PCR. While light microscopy showed higher specificity and PPV, qPCR effectively detected low parasitemia levels missed by microscopy, highlighting its value in improving malaria diagnostics.

1 January 2026 in Journal of Tropical Medicine
Verified
Journal Article
Open access
PDF file
MAMusa A. Ayashi
Musa A. Ayashi
AMAhmed A. Muyidi
Ahmed A. Muyidi
Majed H. WakidMajed H. Wakid
Majed H. Wakid
FBFadi Mohammad Baakdah
Fadi Mohammad Baakdah
MAMaimonah S. Alghanmi
Maimonah S. Alghanmi
TBThamer M. Brek
Thamer M. Brek
Background: Saudi Arabia has reported no indigenous malaria since 2021 and is in the prevention‐of‐reintroduction phase, with residual and imported infections concentrated in Jazan and Aseer. At this stage, each reported case triggers programmatic action, yet the operational accuracy of routine facility diagnostics has not been measured in this setting. Objective: To evaluate the operational accuracy of facility‐performed routine light microscopy (RLM) and two Pf/PAN rapid diagnostic tests (RDTs) against species‐specific nested PCR. Methods: Retrospective diagnostic accuracy study on consecutively archived specimens. Of 118 archived EDTA samples from febrile patients tested for suspected malaria at hospitals in nine governorates of southwestern Saudi Arabia during January–December 2023, 106 were eligible (12 were excluded). Index tests were performed by facility staff during routine care; nested PCR was later performed blinded. Accuracy was assessed against nested PCR and, in a sensitivity analysis, a composite reference (RLM or PCR positive). Results: Nested PCR detected Plasmodium in 81/106 samples (76.4%; 95% CI 67.2–84.0), all single‐species ( P. falciparum 56/81; P. vivax 25/81). RLM was positive in 98/106 (92.5%), CareStart in 106/106 (100%), QuickProfile in 100/106 (94.3%). RLM called 29/98 positives mixed (29.6%) versus 0/81 by PCR (Fisher’s exact, p < 0.001). Against PCR, RLM sensitivity was 97.5% (91.3–99.6) and specificity 24.0% (10.2–45.5); CareStart specificity 0% (0–13.9), QuickProfile 20.0% (8.1–39.8). PCR confirmation increased with reported parasitemia, from 12/23 (52.2%) at 10–90 parasites/μL to 22/24 (91.7%) at 1000–10,000 parasites/μL (Cochran–Armitage, p < 0.001). Conclusion: In the selected clinically suspected cases, routine diagnostics returned more positives, and far more mixed infections, than nested PCR; both routine false positives and reduced PCR sensitivity in archived material plausibly contribute. Findings should not be extrapolated beyond this population. Strengthened microscopy training, RDT quality assurance, and evaluation of molecular confirmation may support case classification during the prevention‐of‐reintroduction phase.