Yuta Kobayashi

Yuta Kobayashi

Auto-generated profile, based on publicly available information

Yuta Kobayashi

Research and Development Directorate, Japan Aerospace Exploration Agency, Tsukuba, Ibaraki Japan 305-8505

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2016 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
YKYuta Kobayashi
Yuta Kobayashi
SKShigeo Kawasaki
Shigeo Kawasaki
An X-band, 15-W-class gallium nitride (GaN) solid-state power amplifier (SSPA) for the 50-kg-class ultrasmall deep-space probe PROCYON has been demonstrated in deep space for the first time. PROCYON was launched on December 3, 2014, as a subpayload of the Hayabusa 2 spacecraft. The GaN SSPA consists of three-stage, single-end amplifiers. The final-stage GaN high-power amplifier, which dominates the characteristics of the SSPA, achieves a maximum drain efficiency of 55.8% at 8.4 GHz. The fabricated SSPA using this GaN high-power amplifier has dimensions of 150 x 120 x 62 mm and weighs 1.5 kg, and its space applicability was confirmed through space environmental tests. For more than 2450 h of continuous operation in deep space, the GaN SSPA has achieved an average output power of 41.7 dBm (14.8 W), with standard deviation of 0.12 dB, maximum overall efficiency of 35.7%, and average efficiency of 33.8%. To the authors' knowledge, this is the highest efficiency of all proven X-band onboard SSPAs.

26 March 2018 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
YKYuta Kobayashi
Yuta Kobayashi
ESEdson H. Sekiya
Edson H. Sekiya
KSKazuya Saito
Kazuya Saito
RNRyoichi Nishimura
Ryoichi Nishimura
KIKentaro Ichii
Kentaro Ichii
TATomohiro Araki
Tomohiro Araki
This study demonstrates that phosphorus-related radiation-induced absorption (RIA) bands such as P-OHC and P1 in erbium/ytterbium-doped optical fibers (EYDFs) are effectively decreased by germanium (Ge) co-doping. The suppression of the generation of both P-OHC during X-ray irradiation of glass preforms and P1 during gamma-ray irradiation of optical fibers was measured for Ge concentrations between 0 wt% and 6.7 wt%. For the 10 krad X-ray irradiation of glass preforms, it was found that the RIA decreased from 5.6 dB/cm to 1.3 dB/cm when the Ge concentration was increased from 0.79 wt% to more than 4.4 wt%. Furthermore, in multi-mode optical fibers (MMFs) exposed to 100 krad of gamma-ray irradiation, the RIA decreased from 3.7 dB/m to 0.90 dB/m when the Ge concentration was increased from 0.0 wt% to 4.0 wt%, whereas it was 0.35 dB/m for a single-mode optical fiber (SMF) with a Ge concentration of 6.7 wt%. These results demonstrate that Ge concentrations up to 4.4 wt% are strongly correlated with improved radiation tolerance for both glass preforms and optical fibers. This effect was more prominent for SMFs than MMFs and became saturated with excess co-doping in both cases. Therefore, Ge co-doping may represent a good solution for reducing P-related RIA in EYDFs for space applications.

23 April 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
YKYuta Kobayashi
Yuta Kobayashi
ESEdson H. Sekiya
Edson H. Sekiya
MBMizuki Banno
Mizuki Banno
RNRyoichi Nishimura
Ryoichi Nishimura
TOTomoya Okazaki
Tomoya Okazaki
KSKazuya Saito
Kazuya Saito
Erbium (Er)- and Ytterbium (Yb)-doped optical fibers (EYDFs) have been used in various industrial fields as the only technology suitable for >1 W high-power amplifiers in the 1550-nm band. The output power is mainly limited by unwanted 1-μm band amplified spontaneous emissions from excited Yb3+; however, the factors affecting the output performance remain unclear. Here, we quantitatively and systematically reveal that the Phosphorus (P)-to-rare earth atomic ratio in the EYDFs has an optimal value for achieving the best output performance of EYDFs. We experimentally evaluated the quantitative relationship among co-dopants by fabricating preforms, drawing them as fibers, and measuring the amplification characteristics. At an appropriate Er concentration (0.3—0.5 wt %), a pump-to-signal conversion efficiency of 45.4% was obtained when the P/(Yb + Er) atomic ratio was around 25. This study paves the way for energy saving in high-power applications, such as high-speed optical wireless communication and long-distance optical ranging.

19 April 2018 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Closed access
MTMizuki Tenjimbayashi
Mizuki Tenjimbayashi
JPJun-Yong Park
Jun-Yong Park
JMJun Muto
Jun Muto
YKYuta Kobayashi
Yuta Kobayashi
RYRyohei Yoshikawa
Ryohei Yoshikawa
SSSeimei Shiratori
Seimei Shiratori

27 August 2018 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
YKYuta Kobayashi
Yuta Kobayashi
ATAtsushi Tomiki
Atsushi Tomiki
SKShigeo Kawasaki
Shigeo Kawasaki
An X-band, Gallium nitride (GaN)-based solid-state power amplifier (SSPA) was demonstrated for more than one year in deep space for the first time. The SSPA consisted of three-stage amplifiers and commercial off-the-shelf (COTS) GaN high-electron-mobility transistors (HEMTs) were used in both the second- and the final-stage amplifiers. During its one year of continuous operation, the GaN SSPA improved equivalent isotopically radiated power (EIRP) with low power consumption such as an average output power of 41.7 dBm (14.8 W), average power consumption of 43.5 W and average efficiency of 33.7%. In addition, the deterioration rate of output power calculated from the inclination of the linear approximation line was no more than -0.08 dB per year. These results stand comparison with the results of high-temperature, long-term continuous operation test or a total ionizing dose test conducted on the ground. This paper illustrates the space applicability and reliability of the SSPA using a COTS GaN HEMT

20 January 2025
Verified
Conference Paper
Open access
TMTakashi Maeda
Takashi Maeda
YKYuta Kobayashi
Yuta Kobayashi
NTNguyen Tat Trung
Nguyen Tat Trung
TYTsutomu Yano
Tsutomu Yano
NTNaoya Tomii
Naoya Tomii
Scanning Array for hyper-Multispectral RAdiowave Imaging (SAMRAI) is a passive interferometric radiometer. In this respect, it is similar to MIRAS on board the SMOS satellite launched by ESA, but it realizes ultra-wideband (1-41 GHz) and high-frequency-resolution (27 MHz) microwave spectrum measurement. We believe that SAMRAI is the world's first microwave hyperspectral radiometer.JAXA will continue to operate the satellite-borne microwave radiometer AMSR series for more than 30 years, including AMSR3 currently under development. The design has remained largely unchanged for 30 years, and various issues are becoming apparent. In particular, the radio frequency interference (RFI) contaminating the natural-origin signals is a serious problem, and we believe that microwave hyperspectral measurement is essential for identifying and isolating RFI signals. This was a big motivation for developing SAMRAI. However, microwave hyperspectral measurement must have new possibilities, such as making it possible to measure the frequency characteristics of the emissivity of the Earth surface.SAMRAI's key technologies are:1) ultra-highspeed A/D conversion equivalent to 80 GSPS (SPS : samples per second)2) ultra-wideband antenna (1 - 41 GHz) as an element of a phased array antenna (PAA) system3) on-board data processing for an interferometer using FPGA including mitigation of grating lobesSAMRAI was first developed to be mounted on a helicopter (aircraft-borne SAMRAI), and its performance is currently being confirmed. Based on performance confirmation of the aircraft-borne SAMRAI, the final goal is to develop the satellite-borne SAMRAI and launch it in 2027.Here, we presents the detail of the technical points of SAMRAI, the performance confirmation results of the observation experiment by the aircraft-borne SAMRAI and investigation of a new algorithm for geophysical value retrieval based on microwave spectrum measurement.