1 January 2017 in Intestinal Research
Shin SJ, et al. Intest Res. 2017 Oct;15(4):446-455. https://doi.org/10.5217/ir.2017.15.4.446
1 August 2014 in American Journal of Gastroenterology
This study aimed to evaluate the risk of development of hepatocellular carcinoma (HCC) according to underlying liver status and virological response (VR) to entecavir (ETV) in chronic hepatitis B patients with cirrhosis. Procollagen III N-terminal peptide (PIIINP) concentration during ETV treatment and its association with HCC development were also evaluated. A total of 306 patients with clinically diagnosed liver cirrhosis were treated with ETV for ≥12 months and were subsequently followed up for the occurrence of HCC (median follow-up duration: 37.0 months). Patients who developed HCC within 12 months were excluded. VR was defined as a hepatitis B virus DNA level 50 years (hazard ratio (HR)=8.41; 95% confidence interval (CI)=3.86-18.28; P=0.000), male sex (HR=4.24; 95% CI=1.83-9.81; P=0.001), high serum PIIINP level at 12 months (HR=1.07; 95% CI=1.02-1.13; P=0.007), and no VR at 12 months (HR=2.10; 95% CI=1.02-4.33; P=0.043). The subgroup analyses showed that no VR at 12 months is a significant risk factor for developing HCC in the patients with decompensated cirrhosis (HR=7.74; 95% CI=1.34-44.78; P=0.022) but not in those with compensated cirrhosis (P=0.749). The antiviral treatment with ETV did not completely eliminate the risk of developing HCC in our patients with cirrhosis. However, VR to ETV was associated with a low probability that the patients with decompensated cirrhosis would develop HCC.
17 November 2010 in Scandinavian Journal of Gastroenterology
Objective. Although still controversial, bilateral stenting may be the best option for palliative drainage of malignant hilar biliary obstruction. The aim of our study was to evaluate the technical and clinical efficacies of endoscopic bilateral metal stenting using a biliary Y-stent for the management of malignant hilar obstruction. Material and methods. This prospective, uncontrolled study included 30 consecutive patients with unresectable malignant hilar strictures in whom we intended to perform endoscopic bilateral stent-in-stent deployment using a biliary Y-stent. After deployment of the Y-stent across the hilar stricture, a conventional biliary metal stent was inserted in a Y-configuration in which it traversed the wider-mesh central portion of the Y-stent to enter the opposite hepatic lobe. Results. Bilateral metal stenting using a Y-stent was successful in 26 of 30 patients (86.7%), and successful drainage was achieved in all 26 patients (100%). Early complications occurred in 3 patients (cholangitis, 1; cholecystitis, 2) without procedure-related mortality. As late complications during the follow-up period (median, 176 days; range, 70–473 days), stent occlusion occurred in 10 of 26 patients (38.5%). Four patients were managed with the insertion of a plastic stent through the occluded metal stent, and the remaining patients were treated with percutaneous biliary drainage. The median survival and stent patency were 176 days and 140 days, respectively. Conclusions. Y-shaped endoscopic bilateral stenting using a Y-stent appears to be a feasible and effective method with high technical success and low stent-related complications for palliation of unresectable malignant hilar biliary obstruction.
8 March 2012 in Surgical Endoscopy
22 June 2015 in Scandinavian Journal of Gastroenterology
Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.
1 April 2016 in Digestive and Liver Disease