Shaozhen Song

Shaozhen Song

Auto-generated profile, based on publicly available information

Shaozhen Song

Univ. of Washington

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MKMitchell A. Kirby
Mitchell A. Kirby
IPIvan Pelivanov
Ivan Pelivanov
SSShaozhen Song
Shaozhen Song
ŁAŁukasz Ambrozinski
Łukasz Ambrozinski
SYSoon Joon Yoon
Soon Joon Yoon
MOMatthew O’dOnnell
Matthew O’dOnnell
Optical coherence tomography (OCT) has outstanding spatial resolution, noncontact operation, and sufficient penetration depth in ocular tissues, making it a nearly perfect match for ophthalmologic applications. In addition to micron-level spatial resolution, OCT can detect tissue motion with exquisite sensitivity, making it feasible for in vivo sensing of micro- and nanoscale displacement within a sample. Because of this, OCT can be used in specific configurations to probe biomechanical properties, a technique referred to as optical coherence elastography (OCE).1 In theory, OCT generates a structural image based on light scattering determined by minute changes in the refractive index of different tissue and cell types, while OCE utilizes local tissue motion as a function of an applied stress to infer tissue stiffness (i.e., elasticity). An OCE system may be described in terms of the steps required to probe tissue elasticity: (1) mechanical loading, (2) tissue response, and (3) motion detection, as shown in Fig. 1.

22 October 2013 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SSShaozhen Song
Shaozhen Song
ZHZhihong Huang
Zhihong Huang
Ruikang WangRuikang Wang
Ruikang Wang
We describe theoretical and experimental investigations of motion artifacts that can arise in the detection of shear wave propagating within tissue with phase-sensitive optical coherence tomography. We find that the motion artifact is a combined product of sample surface motion and refractive index difference between sample and air, which cannot be neglected when estimating the tissue motion within tissue. A method of compensating the motion artifact is demonstrated, the results of which emphasize the need for surface motion compensation when measuring the mechanical response for elastography or other biomedical applications.

8 November 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SSShaozhen Song
Shaozhen Song
ZHZhihong Huang
Zhihong Huang
TNThu-Mai Nguyen
Thu-Mai Nguyen
EWEmily Y. Wong
Emily Y. Wong
BABastien Arnal
Bastien Arnal
Ruikang WangRuikang Wang
Ruikang Wang
We propose an integrated method combining low-frequency mechanics with optical imaging to map the shear modulus within the biological tissue. Induced shear wave propagating in tissue is tracked in space and time using phase-sensitive optical coherence tomography (PhS-OCT). Local estimates of the shear-wave speed obtained from tracking results can image the local shear modulus. A PhS-OCT system remotely records depth-resolved, dynamic mechanical waves at an equivalent frame rate of ∼47  kHz with the high spatial resolution. The proposed method was validated by examining tissue-mimicking phantoms made of agar and light scattering material. Results demonstrate that the shear wave imaging can accurately map the elastic moduli of these phantoms.

1 February 2015 in Cancer Letters
Verified
Journal Article
Closed access
CLChunhui Li
Chunhui Li
GGGuangying Guan
Guangying Guan
YLYuting Ling
Yuting Ling
YHYing-Ting Hsu
Ying-Ting Hsu
SSShaozhen Song
Shaozhen Song
Ghulam NabiGhulam Nabi
Ghulam Nabi

6 February 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TNThu-Mai Nguyen
Thu-Mai Nguyen
SSShaozhen Song
Shaozhen Song
BABastien Arnal
Bastien Arnal
ZHZhihong Huang
Zhihong Huang
MOMatthew O’donnell
Matthew O’donnell
Ruikang WangRuikang Wang
Ruikang Wang
We report on the use of phase-sensitive optical coherence tomography (PhS-OCT) to detect and track temporal and spatial shear wave propagation within tissue, induced by ultrasound radiation force. Kilohertz-range shear waves are remotely generated in samples using focused ultrasound emission and their propagation is tracked using PhS-OCT. Cross-sectional maps of the local shear modulus are reconstructed from local estimates of shear wave speed in tissue-mimicking phantoms. We demonstrate the feasibility of combining ultrasound radiation force and PhS-OCT to perform high-resolution mapping of the shear modulus.

18 September 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MKMitchell A. Kirby
Mitchell A. Kirby
KZKanheng Zhou
Kanheng Zhou
JPJohn J. Pitre
John J. Pitre
LGLiang Gao
Liang Gao
DLDavid S. Li
David S. Li
MOMatthew O'DOnnell
Matthew O'DOnnell
Optical coherence elastography (OCE) uses optical coherence tomography (OCT) to detect local tissue displacement following an applied force, enabling the quantification of biomechanical properties within a region of interest. OCE can potentially identify pathologies opaque to classical OCT using local maps of tissue mechanical properties (namely Young’s modulus), which can vary greatly between healthy and disease states. Detecting spatial heterogeneities in a mechanical structure can help monitor and treat disease progression in numerous fields, including ophthalmology,1 – 5 dermatology,6 cardiology,7 gastroenterology,8 and oncology.9 – 11 While it is a general belief that dynamic OCE is capable of high-resolution (on the order of the imaging modality, OCT) mapping of tissue mechanical properties, the spatial resolution in wave-based optical elastography has not yet been characterized.