Felix-Ekkehard von Horstig

Felix-Ekkehard von Horstig

Auto-generated profile, based on publicly available information

Felix-Ekkehard von Horstig

Quantum Motion 9 Sterling Way N7 9HJ London United Kingdom

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
FHFelix-Ekkehard von Horstig
Felix-Ekkehard von Horstig
DIDavid J. Ibberson
David J. Ibberson
GOGiovanni A. Oakes
Giovanni A. Oakes
LCLaurence Cochrane
Laurence Cochrane
DWDavid F. Wise
David F. Wise
MGM. Fernando Gonzalez-Zalba
M. Fernando Gonzalez-Zalba
Fast measurements of quantum devices is useful in areas such as quantum sensing, quantum computing, and nanodevice quality analysis. Here, we develop a superconductor-semiconductor multimodule microwave assembly to demonstrate charge-state readout at the state of the art. The assembly consist of a superconducting readout resonator interfaced to a silicon-on-insulator (SOI) chiplet containing quantum dots (QDs) in a high-κ nanowire transistor. The superconducting chiplet contains resonant and coupling elements as well as LC filters that, when interfaced with the silicon chip, result in a resonant frequency f=2.12 GHz, a loaded quality factor Q=850, and a resonator impedance Z=470Ω. Combined with the large gate lever arms of SOI technology, we achieve a minimum integration time for single and double QD transitions of 2.77 and 13.5 ns, respectively. We utilize the assembly to measure charge noise over 9 decades of frequency up to 500 kHz and find a 1/f dependence across the whole frequency spectrum as well as a charge-noise level of 4μeV/Hz at 1 Hz. The modular microwave circuitry presented here can be directly utilized in conjunction with other quantum devices to improve the readout performance as well as enable large bandwidth noise spectroscopy, all without the complexity of superconductor-semiconductor monolithic fabrication.

2 May 2024 in arXiv
Verified
Preprint
Open access
PDF file
FHFelix-Ekkehard von Horstig
Felix-Ekkehard von Horstig
DIDavid J. Ibberson
David J. Ibberson
GOGiovanni A. Oakes
Giovanni A. Oakes
LCLaurence Cochrane
Laurence Cochrane
DWDavid F. Wise
David F. Wise
MGM. Fernando Gonzalez-Zalba
M. Fernando Gonzalez-Zalba
Fast measurements of quantum devices is important in areas such as quantum sensing, quantum computing and nanodevice quality analysis. Here, we develop a superconductor-semiconductor multi-module microwave assembly to demonstrate charge state readout at the state-of-the-art. The assembly consist of a superconducting readout resonator interfaced to a silicon-on-insulator (SOI) chiplet containing quantum dots (QDs) in a high-$κ$ nanowire transistor. The superconducting chiplet contains resonant and coupling elements as well as $LC$ filters that, when interfaced with the silicon chip, result in a resonant frequency $f=2.12$ GHz, a loaded quality factor $Q=850$, and a resonator impedance $Z=470$ $Ω$. Combined with the large gate lever arms of SOI technology, we achieve a minimum integration time for single and double QD transitions of 2.77 ns and 13.5 ns, respectively. We utilize the assembly to measure charge noise over 9 decades of frequency up to 500 kHz and find a 1/$f$ dependence across the whole frequency spectrum as well as a charge noise level of 4 $μ$eV/$\sqrt{\text{Hz}}$ at 1 Hz. The modular microwave circuitry presented here can be directly utilized in conjunction with other quantum device to improve the readout performance as well as enable large bandwidth noise spectroscopy, all without the complexity of superconductor-semiconductor monolithic fabrication.