Andrea Perego

Andrea Perego

Auto-generated profile, based on publicly available information

Andrea Perego

University of California Irvine

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2017 in Sustainable Energy & Fuels
Verified
Journal Article
Closed access
PDF file
DBDavide Beretta
Davide Beretta
APA. Perego
A. Perego
GLG. Lanzani
G. Lanzani
MCMario Caironi
Mario Caironi
Organic thermoelectrics are emerging as strong candidates for micro energy harvesting devices to power low energy electronics and serve as sustainable distributed energy supplies. Here their actual potential is assessed with respect to different applications scenarios, such as wearables and sensors networks, providing useful guidelines for their future development.

8 June 2020 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
LCLei Cheng
Lei Cheng
KKKaustubh Khedekar
Kaustubh Khedekar
MTMorteza Rezaei Talarposhti
Morteza Rezaei Talarposhti
APAndrea Perego
Andrea Perego
MMMichael Metzger
Michael Metzger
CJChristina M. Johnston
Christina M. Johnston

5 January 2020 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
DSDinesh C. Sabarirajan
Dinesh C. Sabarirajan
JLJiangjin Liu
Jiangjin Liu
YQYongzhen Qi
Yongzhen Qi
APAndrea Perego
Andrea Perego
AHAndrew T. Haug
Andrew T. Haug
IZIryna V. Zenyuk
Iryna V. Zenyuk
Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

30 April 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
YQYongzhen Qi
Yongzhen Qi
JLJiangjin Liu
Jiangjin Liu
DSDinesh C. Sabarirajan
Dinesh C. Sabarirajan
YHYing Huang
Ying Huang
APAndrea Perego
Andrea Perego
IZIryna V. Zenyuk
Iryna V. Zenyuk
A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%–120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeration within the PCLs.

24 October 2005 in Physical Review C
Verified
Journal Article
Open access
PDF file
AGA. Giannatiempo
A. Giannatiempo
APA. Perego
A. Perego
PSP. Sona
P. Sona
ANA. Nannini
A. Nannini
HMH. Mach
H. Mach
KGK. Gulda
K. Gulda
The properties of the excited states of Kr76, populated in the decay of Rb76 produced at ISOLDE isotopic separator, have been investigated by using K-conversion electron, γ-ray, and γ-γ coincidence measurements. The lifetimes of several levels have been measured by means of the advanced time-delayed βγγ(t) method. The identification of 19 new levels and 55 transitions and the information deduced on spin and/or parity of the observed states from K-conversion coefficients, log ft values and decay properties have led to an improved knowledge of the level scheme. In particular, six 1− states have been definitely identified and Jπ=2− has been assigned to the 2227 keV level, on which a band proposed to have negative-parity and even-spin had been previously observed. The strengths of the E0 and E2 transitions deexciting the 02+ and 03+ states (the latter is here identified with the state at 1598 keV) have been measured. The experimental data concerning the 02+ state have been analyzed in a simple two states mixing model and in the framework of the proton-neutron interacting boson model.

30 January 2019 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
APAndrea Perego
Andrea Perego
GGGiorgio Giuffredi
Giorgio Giuffredi
PMPiero Mazzolini
Piero Mazzolini
MCMassimo Colombo
Massimo Colombo
RBRosaria Brescia
Rosaria Brescia
FFFabio Di Fonzo
Fabio Di Fonzo