Graham M. Treece

Graham M. Treece

Auto-generated profile, based on publicly available information

Graham M. Treece

Department of Engineering, University of Cambridge, Cambridge, U.K.

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Medical Image Analysis
Verified
Journal Article
Open access
GTG.M. Treece
G.M. Treece
AGA.H. Gee
A.H. Gee
PMP.M. Mayhew
P.M. Mayhew
KPK.E.S. Poole
K.E.S. Poole
The distribution of cortical bone in the proximal femur is believed to be a critical component in determining fracture resistance. Current CT technology is limited in its ability to measure cortical thickness, especially in the sub-millimetre range which lies within the point spread function of today's clinical scanners. In this paper, we present a novel technique that is capable of producing unbiased thickness estimates down to 0.3mm. The technique relies on a mathematical model of the anatomy and the imaging system, which is fitted to the data at a large number of sites around the proximal femur, producing around 17,000 independent thickness estimates per specimen. In a series of experiments on 16 cadaveric femurs, estimation errors were measured as -0.01+/-0.58mm (mean+/-1std.dev.) for cortical thicknesses in the range 0.3-4mm. This compares with 0.25+/-0.69mm for simple thresholding and 0.90+/-0.92mm for a variant of the 50% relative threshold method. In the clinically relevant sub-millimetre range, thresholding increasingly fails to detect the cortex at all, whereas the new technique continues to perform well. The many cortical thickness estimates can be displayed as a colour map painted onto the femoral surface. Computation of the surfaces and colour maps is largely automatic, requiring around 15min on a modest laptop computer.

1 April 2003 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
GTGraham M Treece
Graham M Treece
AGAndrew H Gee
Andrew H Gee
RPRichard W Prager
Richard W Prager
CCCharlotte J.C Cash
Charlotte J.C Cash
LBLaurence H Berman
Laurence H Berman

1 July 2012 in Medical Image Analysis
Verified
Journal Article
Open access
GTG.M. Treece
G.M. Treece
KPK.E.S. Poole
K.E.S. Poole
AGA.H. Gee
A.H. Gee
There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm(2)) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex.

1 February 2015 in Medical Image Analysis
Verified
Journal Article
Open access
GTG.M. Treece
G.M. Treece
AGA.H. Gee
A.H. Gee
The local structure of the proximal femoral cortex is of interest since both fracture risk, and the effects of various interventions aimed at reducing that risk, are associated with cortical properties focused in particular regions rather than dispersed over the whole bone. Much of the femoral cortex is less than 3mm thick, appearing so blurred in clinical CT that its actual density is not apparent in the data, and neither thresholding nor full-width half-maximum techniques are capable of determining its width. Our previous work on cortical bone mapping showed how to produce more accurate estimates of cortical thickness by assuming a fixed value of the cortical density for each hip. However, although cortical density varies much less over the proximal femur than thickness, what little variation there is leads to errors in thickness measurement. In this paper, we develop the cortical bone mapping technique by exploiting local estimates of imaging blur to correct the global density estimate, thus providing a local density estimate as well as more accurate estimates of thickness. We also consider measurement of cortical mass surface density and the density of trabecular bone immediately adjacent to the cortex. Performance is assessed with ex vivo clinical QCT scans of proximal femurs, with true values derived from high resolution HRpQCT scans of the same bones. We demonstrate superior estimation of thickness than is possible with alternative techniques (accuracy 0.12 ± 0.39 mm for cortices in the range 1-3mm), and that local cortical density estimation is feasible for densities >800 mg/cm(3).

1 January 2000 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GTG.M. Treece
G.M. Treece
RPR.W. Prager
R.W. Prager
AGA.H. Gee
A.H. Gee
LBL. Berman
L. Berman
The ability to estimate a surface from a set of cross sections allows calculation of the enclosed volume and the display of the surface in three-dimensions. This process has increasingly been used to derive useful information from medical data. However, extracting the cross sections (segmenting) can be very difficult, and automatic segmentation methods are not sufficiently robust to handle all situations. Hence, it is an advantage if the surface reconstruction algorithm can work effectively on a small number of cross sections. In addition, cross sections of medical data are often quite complex. Shape-based interpolation is a simple and elegant solution to this problem, although it has known limitations when handling complex shapes. In this paper, the shape-based interpolation paradigm is extended to interpolate a surface through sparse, complex cross sections, providing a significant improvement over the authors' previously published maximal disc-guided interpolation. The performance of this algorithm is demonstrated on various types of medical data (X-ray computed tomography, magnetic resonance imaging and three-dimensional ultrasound). Although the correspondence problem in general remains unsolved, it is demonstrated that correct surfaces can be estimated from a limited amount of real data, through the use of region rather than object correspondence.

1 April 2009 in Medical Image Analysis
Verified
Journal Article
Open access
LCLujie Chen
Lujie Chen
GTGraham M. Treece
Graham M. Treece
JLJoel E. Lindop
Joel E. Lindop
AGAndrew H. Gee
Andrew H. Gee
RPRichard W. Prager
Richard W. Prager
Displacement estimation is a key step in the evaluation of tissue elasticity by quasistatic strain imaging. An efficient approach may incorporate a tracking strategy whereby each estimate is initially obtained from its neighbours' displacements and then refined through a localized search. This increases the accuracy and reduces the computational expense compared with exhaustive search. However, simple tracking strategies fail when the target displacement map exhibits complex structure. For example, there may be discontinuities and regions of indeterminate displacement caused by decorrelation between the pre- and post-deformation radio frequency (RF) echo signals. This paper introduces a novel displacement tracking algorithm, with a search strategy guided by a data quality indicator. Comparisons with existing methods show that the proposed algorithm is more robust when the displacement distribution is challenging.