Early versions of uncemented femoral total hip stems were often associated with thigh pain thought to be due to micromotion between the implant and bone in the distal uncoated regions. An extensively coated stem was introduced in 1992 to reduce that risk. We therefore asked whether second-generation extensively porous-coated cementless femoral stems in patients younger than 50 years of age would (1) be durable in terms of revisions; (2) provide high functional scores and reduce thigh pain; and (3) show radiographic signs of durability, including a reduction in stress shielding. We prospectively followed all 100 patients (115 hips) age 50 and younger treated with primary cementless total hip arthroplasties using a second-generation extensively porous-coated femoral stem between June 1994 and December 1999. The average age was 39.6 years (range, 17-50 years). The stems were mated to cementless acetabular components. Ninety patients were followed for a minimum of 5 years (mean, 8.6 years; range, 5-10 years). One stem was revised after a periprosthetic fracture. None were revised for loosening and all stems demonstrated bony ingrowth at last followup. No acetabular shell was revised for loosening and none was radiographically loose. Six acetabular liners were revised for wear (three each were 22-mm and 26-mm heads). This second-generation extensively porous-coated stem was durable at 5- to 10-year followup in this young active population. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Enhanced myometrial vascularity is a pregnancy-related hypervascularity that may persist with retained products of conception and is distinct from arteriovenous malformation in cause, imaging findings, and management.
Use of CT continues to increase steadily with shorter image-acquisition times and improving image quality. CT of the chest frequently is ordered for evaluation of the pulmonary or cardiac system. As with any modality, nontarget tissues often are imaged along with the tissues in question. In chest CT, the breast tissue is included in the field of view. It is not uncommon to find incidental breast lesions on chest CT; and, therefore, it is imperative that all the tissues included in the images are evaluated carefully. CT is not a diagnostic modality for an incidental breast lesion; nonetheless, CT may be the initial modality of detection. The role of this article is to show examples of common breast pathology encountered while interpreting routine chest CT and to demonstrate their mammographic and ultrasound correlates.