Takato Mohri

Takato Mohri

Auto-generated profile, based on publicly available information

Takato Mohri

Department of Cardiovascular Medicine, Kyorin University School of Medicine , Mitaka , Japan

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
TSToshiaki Sato
Toshiaki Sato
ITIkuko Togashi
Ikuko Togashi
HIHirotsugu Ikewaki
Hirotsugu Ikewaki
TMTakato Mohri
Takato Mohri
YKYumi Katsume
Yumi Katsume
KSKyoko Soejima
Kyoko Soejima
Aims: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. Methods and results: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. Conclusion: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.

1 October 2020 in HeartRhythm Case Reports
Verified
Journal Article
Open access
TMTakato Mohri
Takato Mohri
OIOsamu Igawa
Osamu Igawa
KIKazunobu Isogaya
Kazunobu Isogaya
KHKyoko Hoshida
Kyoko Hoshida
ITIkuko Togashi
Ikuko Togashi
KSKyoko Soejima
Kyoko Soejima

21 December 2017 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
TMTakato Mohri
Takato Mohri
MSMike Saji
Mike Saji
TMTatsuya Murai
Tatsuya Murai
MTMorimasa Takayama
Morimasa Takayama
Although atrial fibrillation (AF) often exists in patients with hypertrophic obstructive cardiomyopathy (HOCM), combination of tricuspid regurgitation (TR) and AF after implantation of pacemaker/implantable cardioverter defibrillator (ICD) lead and its optimal management have not been well discussed in this population. Herein, we present a patient with HOCM who subsequently died due to severe heart failure and deterioration of TR following ICD lead placement with AF. Autopsy findings demonstrated that ICD leads were entrapped by anomaly structure in the right atrium and ventricle, which might affect deterioration of TR.