William Moreno

William Moreno

Auto-generated profile, based on publicly available information

William Moreno

Laboratoire Temps-Fréquence, Institut de Physique, Université de Neuchâtel, Neuchâtel, Switzerland

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
NANil Almat
Nil Almat
MGMohammadreza Gharavipour
Mohammadreza Gharavipour
WMWilliam Moreno
William Moreno
FGFlorian Gruet
Florian Gruet
CAChristoph Affolderbach
Christoph Affolderbach
GMGaetano Mileti
Gaetano Mileti
Long-term frequency instabilities in vapor-cell clocks mainly arise from fluctuations of the experimental and environmental parameters that are converted to clock frequency fluctuations via various physical processes. Here, we discuss the frequency sensitivities and the resulting stability limitations at one day timescale for a rubidium vapor-cell clock based on a compact magnetron-type cavity operated in air (no vacuum environment). Under ambient laboratory conditions, the external atmospheric pressure fluctuations may dominantly limit the clock stability via the barometric effect. We establish a complete long-term instability budget for our clock operated under stable pressure conditions. Where possible, the fluctuations of experimental parameters are measured via the atomic response. The measured clock instability of < 2·E10.14 at one day is limited by the intensity light-shift effect, which could further be reduced by active stabilization of the laser intensity or stronger optical pumping. The analyses reported here show the way towards simple, compact, and low-power vapor-cell atomic clocks with excellent long-term stabilities. ≤ 10.14 at one day when operated in ambient laboratory conditions.

4 June 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
WMWilliam Moreno
William Moreno
MPMatthieu Pellaton
Matthieu Pellaton
CAChristoph Affolderbach
Christoph Affolderbach
GMGaetano Mileti
Gaetano Mileti
Vapor-cell atomic clocks are compact and highperformance frequency references employed in various applications ranging from telecommunication to global positioning systems. Environmental sensitivities are often the main sources of long-term instabilities of the clock frequency. Among these sensitivities, the environmental pressure shift describes the clock frequency change with respect to the environmental pressure variations. We report here on our theoretical and experimental analysis of the environmental pressure shift on Rubidium atomic frequency standards (RAFS) operated under open atmosphere. By using an unsealed highperformance laser-pumped Rubidium standard, we demonstrate that the deformation of the vapor-cell volume induced by the environmental pressure changes (i.e barometric effect) is the dominant environmental pressure shift in a standard laboratory environment. An experimental barometric coefficient of 8.2×10-14/hPa is derived, in good agreement with theory and with previously reported measurements of frequency shifts of RAFS operated when transiting to vacuum.

15 January 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
NANil Almat
Nil Almat
WMWilliam Moreno
William Moreno
MPMatthieu Pellaton
Matthieu Pellaton
FGFlorian Gruet
Florian Gruet
CAChristoph Affolderbach
Christoph Affolderbach
GMGaetano Mileti
Gaetano Mileti
We report on the characterization of two fiber-coupled 1.5-μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vapor-cell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency-stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat-notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise <10 -12 Hz-1 is one order of magnitude lower than the reference 780-nm laser, and the frequency noise <10 6 Hz2 /Hz is limited by the laser current source. Its optical frequency instability is <4 ·10 -12 at τ= 1 s, limited by the reference laser, and better than 1 ∙10 -11 at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.

1 June 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
NANil Almat
Nil Almat
MPMatthieu Pellaton
Matthieu Pellaton
WMWilliam Moreno
William Moreno
FGFlorian Gruet
Florian Gruet
CAChristoph Affolderbach
Christoph Affolderbach
GMGaetano Mileti
Gaetano Mileti
We employ a recently developed laser system, based on a low-noise telecom laser emitting around 1.56 μm, to evaluate its impact on the performance of an Rb vapor-cell clock in a continuous-wave double-resonance scheme. The achieved short-term clock instability below 2.5·10−13·τ−1/2 demonstrates, for the first time, the suitability of a frequency-doubled telecom laser for this specific application. We measure and study quantitatively the impact of laser amplitude and frequency noises and of the ac Stark shift, which limit the clock frequency stability on short timescales. We also report on the detailed noise budgets and demonstrate experimentally that, under certain conditions, the short-term stability of the clock operated with the low-noise telecom laser is improved by a factor of three compared to clock operation using the direct 780-nm laser.

10 May 2021
Verified
Conference Paper
Closed access
MHMutaz Haddadin
Mutaz Haddadin
WMWilliam Moreno
William Moreno
In semiconductor manufacturing, as the silicon wafer diameter continued to increase, the challenges of handling the wafers in a manufacturing environment were manageable until the wafer size was transitioned from 200mm to 300mm diameter. For 300mm, handling wafers manually was deemed unmanageable at high volume due to wafer size, weight of the fully loaded carrier, safety and ergonomics, and fab productivity. Consequently, the industry architects in the mid-1990s leading up to first 300mm fab in 2000, defined a very well thought out vision and strategy of introducing Automated Material Handling Systems (AMHS) that are pervasive throughout the fab.The 300mm AMHS System of Systems was unprecedented and required an industry wide effort to make it a reality. Hence, to enable such a system, industry standards and a fully integrated architecture needed to be developed. This effort required hardware and software components and systems from multiple domains throughout the industry. This paper examines the System of Systems (SoS) architecture concepts of AMHS, the attributes that it delivers, and new capabilities that must be deployed to ensure that the SoS can continue to deliver on the objectives of the client in a volatile requirements and demand profile overtime, given that semiconductor fabs have a long life span of more than two decades.

1 April 2019
Verified
Conference Paper
Closed access
WMW. Moreno
W. Moreno
MPM. Pellaton
M. Pellaton
NAN. Almat
N. Almat
MGM. Gharavipour
M. Gharavipour
CAC. Affolderbach
C. Affolderbach
GMGaetano Mileti
Gaetano Mileti
We employ a three-level Bloch vector model to simulate Ramsey fringes of our Rb vapor-cell atomic clock. The residual inhomogeneity of the microwave magnetic field across the buffer-gas cell is a key ingredient for correctly modelling the behavior at high microwave powers (pulse area > π/2. We add to this model different position-dependent frequency shifts that arise from external fields, and we identify inhomogeneous light-shifts as the dominant contribution for reproducing the measured clock frequency shifts as a function of microwave power. Other frequency shifts give negligible contributions.