Euidam Kim

Euidam Kim

Auto-generated profile, based on publicly available information

Euidam Kim

Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
EKEuidam Kim
Euidam Kim
YPYang Kyun Park
Yang Kyun Park
TZTianyu Zhao
Tianyu Zhao
ELEric Laugeman
Eric Laugeman
XZXiaodong Neo Zhao
Xiaodong Neo Zhao
HLHugh Lee
Hugh Lee
Purpose: The quality of on‐board imaging systems, including cone‐beam computed tomography (CBCT), plays a vital role in image‐guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O‐ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.0 CBCT and providing benchmark data for routine imaging quality assurance.Methods: The HyperSight features ultra‐fast scan time, a larger kilovoltage (kV) detector, a more substantial kV tube, and an advanced reconstruction algorithm. Imaging protocols in the two modes of operation, treatment mode with IGRT and the CBCT for planning (CBCTp) mode were evaluated and compared with Halcyon 3.0 CBCT. Image quality metrics, including spatial resolution, contrast resolution, uniformity, noise, computed tomography (CT) number linearity, and calibration error, were assessed using a Catphan and an electron density phantom and analyzed with TotalQA software.Results: HyperSight demonstrated substantial improvements in contrast‐to‐noise ratio and noise in both IGRT and CBCTp modes compared to Halcyon 3.0 CBCT. CT number calibration error of HyperSight CBCTp mode (1.06%) closely matches that of a full CT scanner (0.72%), making it suitable for adaptive planning. In addition, the advanced hardware of HyperSight, such as ultra‐fast scan time (5.9 s) or 2.5 times larger heat unit capacity, enhanced the clinical efficiency in our experience.Conclusions: HyperSight represented a significant advancement in CBCT imaging. With its image quality, CT number accuracy, and ultra‐fast scans, HyperSight has a potential to transform patient care and treatment outcomes. The enhanced scan speed and image quality of HyperSight are expected to significantly improve the quality and efficiency of treatment, particularly benefiting patients.

1 November 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
TKTae-Eun Kwon
Tae-Eun Kwon
AJAreum Jeong
Areum Jeong
WHWi-Ho Ha
Wi-Ho Ha
DLDalnim Lee
Dalnim Lee
SSSongwon Seo
Songwon Seo
SPSunhoo Park
Sunhoo Park
The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled “Korean Radiation Worker Study,” to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

15 April 2024 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
EKEuidam Kim
Euidam Kim
JYJi Sung Yoo
Ji Sung Yoo
YKYeon-Joo Kim
Yeon-Joo Kim
JJJungnam Joo
Jungnam Joo
EOEun Sang Oh
Eun Sang Oh
TKTae Hyun Kim
Tae Hyun Kim

6 November 2026 in Physica Medica
Verified
Journal Article
Closed access
EKEuidam Kim
Euidam Kim
DCDonghyeok Choi
Donghyeok Choi
YCYoonsun Chung
Yoonsun Chung
HLHugh Lee
Hugh Lee