Jiang Guo

Jiang Guo

Auto-generated profile, based on publicly available information

Jiang Guo

Department of Orthopedics The Second Affiliated Hospital, Sun Yat‐sen University Guangzhou China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2021 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
LPLei Peng
Lei Peng
JGJiang Guo
Jiang Guo
JLJi‐Ping Lu
Ji‐Ping Lu
SJSong Jin
Song Jin
PWPeng Wang
Peng Wang
SHShen Huiyong
Shen Huiyong
Objective: To investigate risk factors of cage retropulsion after posterior lumbar interbody fusion (PLIF) in China and to establish a scoring system of cage retropulsion.Methods: The retrospective analysis was based on two hospital databases. The medical data records of posterior lumbar interbody fusion with cage retropulsion were selected from August 2009 to August 2019. Inclusion and exclusion criteria were set in advance. Risk factors including patients' baseline demographics (age, gender, operation diagnosis time difference), preoperative neurological symptoms, whether the fusion involves single or double segments, screw type, intraoperative compression, preoperative bone mineral density, whether there are neurological symptoms before surgery, whether there is urine dysfunction before surgery, disease type, complete removal of the endplate, and patient's education level. The research endpoint was the retropulsion of fusion cages. The Kaplan–Meier (K‐M) method was used to analyze potential risk factors, and multivariate Cox regression was used to identify independent risk factors (P < 0.05). The Statistical Package for the Social Sciences (version 22.0; SPSS, IBM, Chicago, IL, USA) software was used for statistical analysis, and univariate analysis was used to screen out the factors related to cage retropulsion. All independent risk factors were included to predict the survival time of the retropulsion of cage.Results: This study included a total of 32 patients with PLIF between 2009 to 2019. All patients were residents of China. Univariate analysis showed that there were 13 patients over 60 years old and 19 patients under 60 years old. There were 20 male patients and 12 female patients. The surgical diagnosis time was seven patients within 1 month, 17 patients within 1 to 3 months, and eight patients over 3 months. The disease type was 18 cases of lumbar disc herniation, 10 cases of lumbar spinal stenosis, four cases of lumbar spondylolisthesis. The fusion segment was 18 cases of single segment, 14 cases of double segment. The intraoperative compression was seven cases of compression, 25 cases of no compression. The preoperative bone mineral density was 10 cases of low density, 18 cases of normal, four cases of osteoporosis. The screw type was 27 cases of universal screw, five cases of one‐way screw. Preoperative neurological symptoms were found in 25 cases and not in seven cases. Preoperative urination dysfunction occurred in 8 cases, whereas 24 cases did not have this dysfunction. The endplate was completely removed in 10 cases and not in 22 cases. Education level was nine cases of primary school education, 10 cases of secondary school, 13 cases of university level. Cox regression analysis showed that intraoperative pressure (hazard ratio [HR] = 4.604, P = 0.015) and complete removal of the endplate (HR = 0.205, P = 0.027) are associated with the time of cage retropulsion. According to the HR of each factor, the scoring rules were formulated, and the patients were divided into the low‐risk group, moderate‐risk group, and high‐risk group according to the final score. The three median survival times of the three groups were 66 days in the low‐risk group, 55 days in the moderate‐risk group, and 45 days in the high‐risk group, with statistical significance (P < 0.05).Conclusion: Intraoperative pressure and complete removal of the intraoperative endplate can be helpful to evaluating the expected time of cage retropulsion in patients with PLIF, and this clinical model guided the selection of postoperative prevention and follow‐up treatment.

1 October 2021 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
JGJiang Guo
Jiang Guo
JHJingyi Hou
Jingyi Hou
MYMenglei Yu
Menglei Yu
YAYamuhanmode Alike
Yamuhanmode Alike
YLYi Long
Yi Long
RYRui Yang
Rui Yang
Objective To determine the functional outcomes after a novel method of H-loop knotless double-row technique in patients with rotator cuff tears. Method From June 2020 to September 2020, a total of six patients (five women, one man) with arthroscopic rotator cuff repair using the H-loop knotless double-row technique were enrolled in our study. The average age is 54 years (range: 50–61 years). The preoperative and final follow-up clinical outcome were evaluated using the American Shoulder and Elbow Surgeons (ASES) score, visual analog scale (VAS), University of California Los Angeles (UCLA) score, and Constant–Murley score. The active shoulder range of motion (ROM) was also collected preoperatively and postoperatively at the final follow-up (forward flexion and abduction). Accordingly, intraoperative and postoperative complications were observed as well. Result There were six patients that underwent arthroscopic rotator cuff repair using the H-loop knotless double-row technique. The average follow-up period was 7.52 ± 0.70 months. The VAS, UCLA, ASES, and Constant–Murley scores improved from 5 ± 2.45, 15.67 ± 3.44, 47.67 ± 17.41 and 49.17 ± 8.98 preoperatively, to 0.83 ± 0.75, 36.27 ± 3.83, 91.67 ± 10.76 and 85.83 ± 4.31 at the final follow-up, with statistical significances of P = 0.009, P < 0.001, P = 0.006, and P = 0.001, respectively. Meanwhile, the active shoulder ROM (forward flexion and abduction) improved from 135.00 ± 46.80 and 125 ± 56.48 preoperatively, to 173.67 ± 4.13 and 172 ± 3.27 at final follow-up, respectively (P = 0.082, P = 0.088). During the follow-up, there were no postoperative complications such as wound-site infection, nerve or vessel damage, subcutaneous hematoma, and suture anchor problems. Conclusion With the benefit of reducing the possibility of strangulation and blood supply affection for the rotator cuff, The H-loop knotless double row technique may be an alternative method to significantly improve subjective functional outcomes and increase the healing rate of medium-sized rotator cuff tears with degeneration issues and poor tissue quality.