24 October 2003 in Physics in Medicine & Biology
At the Hyogo Ion Beam Medical Center (HIBMC) we have developed a new design method for the bar ridge filter used in proton therapy, taking into consideration the scattering and nuclear interaction effects within the filter itself, which are introduced in the design. In our beam delivery system, the bar ridge filter is employed as the range modulator. It is combined with the wobbler system, and produces a three-dimensionally uniform spread-out Bragg peak (SOBP). The design program predicts the three-dimensional dose distribution. Ridge filters of 3-12 cm SOBP in 1 cm increments were designed in the maximum radiation field for 150 MeV and 190 MeV proton beams so that a uniform physical dose area is obtained in the SOBP region three-dimensionally. Measurements were performed with the constructed ridge filters to verify the uniformity and these were compared with the predictions of the design program. The predictions and measurements were found to be in agreement except for the 12 cm SOBP. The uniformities were better than +/- 3.0% for all SOBPs produced. The ridge filters are now clinically in use.
26 November 2018 in Radiation Oncology
The usefulness of particle therapy for skull base chordoma has not been established. The aim of this retrospective study was to analyse the treatment outcomes of proton therapy (PT) and carbon ion therapy (CIT) in patients with skull base chordoma at a single institution. All patients who underwent PT or CIT with curative intent between 2003 and 2014 at Hyogo Ion Beam Medical Center were included in this study. Twenty-four patients were enrolled. Eleven (46%) received PT and 13 (54%) received CIT. Overall survival (OS), progression-free survival (PFS) and local control (LC) were calculated using the Kaplan–Meier method. Late toxicities were evaluated according to the Common Terminology Criteria for Adverse Events version 4.0. The median follow-up was 71.5 months (range, 14–175 months). The five-year LC, PFS and OS rates were 85, 81, and 86%, respectively. The LC (P = 0.048), PFS (P = 0.028) and OS (P = 0.012) were significantly improved in patients who had undergone surgery before particle therapy. No significant differences were observed in the LC rate and the incidence of grade 2 or higher late toxicities between patients who received PT and CIT. Both PT and CIT appear to be effective and safe treatments and show potential to become the standard treatments for skull base chordoma. To increase the local control, surgery before particle therapy is preferable.
21 March 2006 in Physics in Medicine & Biology
In the absence of a predictor of beam output in proton therapy using a broad beam, the beam output is obtained for individual treatments by calibrating the beam monitors. The calibration is carried out under conditions similar to the treatment conditions but with a phantom instead of the patient. However, the dose in the phantom a priori differs from that in the patient. In order to deliver the accurate dose, a correction factor has been introduced to correct the difference. This correction factor is referred to as a scatter factor in an analogy with photon therapy, and is defined as the ratio of the dose at the prescription point in the patient to the dose at the calibration point in the phantom. Under the calibration conditions at Hyogo Ion Beam Medical Center (HIBMC), the range compensator and the collimator, which are usually required in proton therapy with a broad beam, are not used. Therefore the scatter factor includes the effects of the devices as well as the difference between the dose in the patient and that in the phantom. We have developed an estimator using a dose calculation based on the pencil beam algorithm and implemented it in a treatment planning system (TPS) for clinical use. This estimator estimates the scatter factor by calculating the ratio of the doses under the same conditions in the TPS. In order to evaluate the performance of the estimator, demonstrations were carried out for cases with measurable outcomes using a gantry nozzle at HIBMC. We observed 2-3% differences between the measurements and the estimations. These differences were considered to result from the limitations of the dose calculation algorithm in modelling the beam and the patient.
25 April 2020 in Medical Physics
16 August 2014 in Radiation Oncology
A study was undertaken to analyze the efficacy and feasibility of particle beam radiation therapy (PBRT) using carbon ions and protons for the treatment of patients with oligometastatic lung tumors. A total of 47 patients with 59 lesions who underwent PBRT for oligometastatic lung tumors between 2003 and 2011 were included in this study. Patient median age was 66 (range, 39–84) years. The primary tumor site was the colorectum in 11 patients (23.4%), lung in 10 patients (21.3%) and a variety of other sites in 26 patients (55.3%). Thirty-one patients (66%) received chemotherapy prior to PBRT. Thirty-three lesions were treated with 320-MeV carbon ions and 26 were treated with 150- or 210-Mev protons in 1–4 portals. A median total dose of 60 (range, 52.8–70.2) GyE was delivered at the isocenter in 8 (range, 4–26) fractions. The median follow-up time was 17 months. The local control, overall survival and progression-free survival rates at 2 years were 79%, 54 and 27% respectively. PBRT-related toxicities were observed; six patients (13%) had grade 2 toxicity (including grade 2 radiation pneumonitis in 2) and six patients (13%) had grade 3 toxicity. Univariate analysis indicated that patients treated with a biologically equivalent dose of 10 (BED10) <110 GyE10, had a significantly higher local recurrence rate. Local control rates were relatively lower in the subsets of patients with the colorectum as the primary tumor site. No local progression was observed in metastases from colorectal cancer irradiated with a BED10 ≥ 110 GyE10. There was no difference in treatment results between proton and carbon ion therapy. PRBT is well tolerated and effective in the treatment of oligometastatic lung tumors. To further improve local control, high-dose PBRT with a BED10 ≥ 110 GyE10 may be promising. Further investigation of PBRT for lung oligometastases is warranted.