Mohammad Amayreh

Mohammad Amayreh

Auto-generated profile, based on publicly available information

Mohammad Amayreh

Department of Chemistry, Faculty of Science, Al-Balqa Applied University, Al-Salt, Jordan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Verified
Journal Article
Open access
MAMohammad Amayreh
Mohammad Amayreh
WHWafa Hourani
Wafa Hourani
MHMohammed Khair Hourani
Mohammed Khair Hourani
In this work, the utilization of the modified iodine-coated polycrystalline platinum electrode as a voltammetric sensor for copper determination in pharmaceutical formulations was reported. The optimized experimental parameters for the determination of copper were using 0.1M KCl as a supporting electrolyte with a scan rate of 50 mV/s, deposition potential of - 0.2 V, and a deposition time of 2 minutes. The anodic peak related to Copper oxidation is centered at about + 0.05 V. The extended detected linear range for the developed method was between 1 ppm and 100 ppm. The anodic current showed excellent linearity with R2 = 0.9986. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.115 ppm and 0.346 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from multivitamins tablet ingredients indicated a specific selectivity toward copper and the absence of any electrochemical response toward these components. The developed method was successfully applied to analyze copper and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with 95 % confidence level.

29 September 2023 in Russian Journal of Electrochemistry
Verified
Journal Article
Closed access
PDF file
MAMohammad Amayreh
Mohammad Amayreh
WHWafa Hourani
Wafa Hourani
SFSafwan Fraihat
Safwan Fraihat
MHMohammed Khair Hourani
Mohammed Khair Hourani
A voltammetric method for the determination of vanillin in food products utilizing iodine-coated polycrystalline platinum electrode is developed. Differential-pulse voltammetry (DPV) was applied for the quantitative determination of vanillin. A 0.1 M KCl solution was used as a supporting electrolyte. The measurements were made in the potential range –0.2 to 1.0 V vs. Ag/AgCl/[Cl–] = 0.1 M and all the reported potentials are referenced to this electrode. The anodic peak for the oxidation of vanillin was observed at ~0.84 V. The calibration curve was constructed for the peak current vs. the vanillin. A linear relationship between the peak current and the vanillin concentration was demonstrated with a calibration equation: ip(μA) = 0.003CVanillin + 0.1237. The working range for the developed method is for 1 to 250 µM and the coefficient of determination R2 is 0.9974. The limit of detection, LOD (based on S/N = 3) is 0.364 µM and the limit of quantitation (based on S/N = 10) is 1.21 µM. The developed method was successfully applied to the analysis of vanillin in food product samples like biscuits, cakes, and wafers with recovery values ranged from 94.41 and 103.18%.

30 May 2024 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
MAMohammad Amayreh
Mohammad Amayreh
MEMuayad Esaifan
Muayad Esaifan
MHMohammed Khair Hourani
Mohammed Khair Hourani

22 October 2024 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
MAM. Amayreh
M. Amayreh
MEM. Esaifan
M. Esaifan
MHM. K. Hourani
M. K. Hourani
The presented work focused on the preparation of a voltammetric sensor for hydroquinone (HQ) determination using a polycrystalline platinum electrode modified with Alizarin Red S (ARS). The electrode was prepared by electropolymerization of ARS on a platinum electrode through the application of 100 cyclic voltammetric segments between –0.4 and 1.2 V against Ag/AgCl (quasi-reference electrode). The modified poly (ARS)-Pt electrode was characterized in terms of stability and cyclic voltammetric behavior as a sensor for HQ in aqueous media. The modified electrode showed excellent stability and higher current than the unmodified electrode for the electrooxidation of HQ. Thus, the oxidation of HQ at poly (ARS)-Pt electrode exhibits notable electrocatalytic performance. The limit of detection is 0.16 µM, and the standard curve exhibits a linear relationship over the range from 0.25 to 15 µM (R2 = 0.999). Investigation of the response to some potential interferences indicated that the electrode is unresponsive to Na+, K+, Mg2+, Ca2+, Zn2+, Mn2+, Mo2+, Co2+, Bi2+, Cd2+, Ni2+, Al3+, \({\text{NO}}_{3}^{ - }\), \({\text{SO}}_{4}^{{2 - }}\), Cl–, phenol and resorcinol, but shows marginal change towards Hg2+ and Cu2+. Recovery tests indicated recovery values between 97.0% and 100.81% when analyzing real samples at the modified electrode.

20 November 2024 in Bioanalysis
Verified
Journal Article
Closed access
MAMohammad Amayreh
Mohammad Amayreh
MHMohammed Khair Hourani
Mohammed Khair Hourani
Aim: By modifying the Pt electrode with polyvinylpyrrolidone, the distinct oxidation potentials of L and D-serine were markedly increased for both isomers.Methods & results: CV was used for Pt electrode modification with PVP. Twenty cycles was reasonable for Pt modification. K3[Fe(CN)6] CV experiments investigated reversibility of the Fe(III) redox reaction and the enhancement of electron transfer at the PVP-Pt electrode. L and D-serine showing an oxidation peak potential at 0.394 V and 0.468 V, respectively. A linear relationship between the anodic oxidation current extracted from the CVs and the standard concentrations of L-serine and D-serine solutions was obtained with R2 = 0.99. The dynamic range for D-serine was from 0.5 to 20 mM with a LOD of 0.16 mM, while for L-serine, was from 2.5 to 20 mM with a detection limit of 0.27 mM. Using DPV, the dynamic range was 0.05-1.0 µM for D-serine with a detection limit of 0.0103 µM. The standard deviation ranged from 0.212 to 0.38 across ten determinations per concentration.Conclusion: A separation by 74 mV between the oxidation peaks of L and D-serine was achieved with remarkable enhancement in oxidation current for both isomers. PVP-Pt electrode can detect D-serine in the presence of DL-serine.

1 January 2021 in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Verified
Journal Article
Open access
MAMohammad Amayreh
Mohammad Amayreh
WHWafa Hourani
Wafa Hourani
MHMohammed Khair Hourani
Mohammed Khair Hourani
In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.