17 August 2022 in IEEE Transactions on Transportation Electrification
Continuous and stable acquisition of accurate three-phase currents information is critical to vector control. The immeasurable areas (IAs) is the most intractable problem in the traditional single current sensor phase current reconstruction (SCS-PCR) technology. In addition, the change of the sampling position owing to the influence of the IAs makes the current ripple tend to be serious, which further increases the current distortion and decreases the current reconstruction accuracy. This article is the first to investigate the influence of the IAs and the current ripple of SCS-PCR. A midpoint value (MPV) random space vector pulsewidth modulation (RSVPWM) reconstruction strategy is proposed, which is based on the Thevenin equivalent circuit of the sampling circuit of SCS-PCR. RSVPWM constructs a current sampling window that satisfies the minimum sampling time to complete two sequential samplings, while the MPV strategy obtains the mean value of two sampling values in the in-phase dynamic current to reduce current ripple. The proposed MPV RSVPWM reconstruction strategy does not require the insertion of redundant voltage vectors and major computation and is not limited to a particular PWM technology. The experimental results verify the accuracy and practicability of the proposed method.
9 May 2019 in IEEE Transactions on Power Electronics
A magnetic integration method of single- and multi-stage electromagnetic interference (EMI) filters is presented. Common-mode (CM) and differential-mode (DM) inductors are integrated into a single magnetic core unit to significantly reduce the filter volume. A 500 W Silicon Carbon (SiC) single-phase inverter is used as an experimental platform. The magnetic integration model is designed, and the magnetic circuit analysis is conducted in a simulation to ensure that the core will not reach magnetic saturation under full load conditions. The feasibility of the proposed method is verified by an EMI test in a simulation and an experiment. Compared with a traditional discrete passive EMI filter (DPEF), the proposed integrated EMI filters can reduce 40% of the total volume and 69% of the inductor volume in integrated single-stage EMI filter (ISSEF) with satisfactory EMI suppression ability. Although the weight of integrated inductor of integrated multi-stage EMI filter (IMSEF) has 23.8% increment, the IMSEF shows a better EMI suppression ability and 4.6% inductor volume reduction.
9 June 2020 in IEEE Transactions on Power Electronics
A day and night operational single-phase energy stored quasi-Z-source cascaded H-bridge (ES-qZS-CHB) inverter photovoltaic (PV) power system to achieve the active and reactive power control is proposed in this paper. The ES-qZS-CHB inverter PV power system usually employs the unity power factor control method to ensure the output current tracking the desired reference in phase with the grid voltage, combining with distributed maximum power point tracking (MPPT) to determine the values of shoot-through duty ratios Dn. These cannot operate at night because there is no PV power input. Meanwhile, as multiple combinations of Dn and modulation ratio Mn could achieve the same voltage gain at night operation, but which is optimal has not been addressed. This paper proposes a solution to address these issues. First, a comprehensive control scheme, which not only has the attractiveness of day and night operation but also shows the advantage of active and reactive power control simultaneously, is proposed; then, an optimization control method is proposed for night operational ES-qZS-CHB inverter to achieve optimal combination of Dn and Mn. Simulation and experimental results validate the day and night operational ES-qZS-CHB inverter and the proposed optimal control technique.
22 December 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The battery energy stored quasi-Z source inverter (BES-qZSI) based photovoltaic (PV) power system combines the advantages of the qZSI and energy storage system. However, as the BES-qZSI is a fast-response power converter without any inertia, when applied as a grid-connected system, it leads to decreased power system inertia. The low inertia problem will degrade the system’s performance and affect the system’s stability. Moreover, The BES-qZSI PV power system usually employs a phase-locked loop and PR regulator to control the grid current to track the desired reference in phase with the grid voltage. These do not reflect the characteristics of frequency modulation and voltage regulation. To enhance the system’s frequency and voltage self-adjustment ability, a control strategy based on virtual synchronous generator (VSG) technique for the BES-qZSI PV power system is proposed in this paper. By introducing the concept of synchronous generator, the BES-qZSI PV power system has the characteristics of heavy moment of inertia, droop frequency-active, droop characteristic of Voltage-reactive power and so on. Then an active power control strategy integrated with reactive power compensation is proposed, to implement PV generation and reactive power compensation at the same time. The simulation and experimental results verify the proposed control strategy.
13 November 2023 in IEEE Transactions on Industry Applications
The DC link current sampling with a single sensor is a promising solution in the electric drive field due to its low cost and small volume. However, limited by the minimum sampling time, the current reconstruction unobservable area is the most intractable challenge in the traditional single sensor reconstruction method, especially in sector boundary areas, where the phase current cannot be reconstructed completely. In this paper, a new non-zero compensation vector pulse width modulation (NCV-PWM) method is proposed to eliminate the current unobservable area. Firstly, by introducing the definition of minimum sampling time, the voltage space vector plane is accurately divided into different modulation areas. Then, by applying non-zero compensation vector in the sector boundary, the current sampling window is extended, and the sampling time requirement for the DC link current is satisfied. Finally, the practicability and accuracy of the NCV-PWM method are verified by experiments, and results show that the current reconstruction error is less than 2.86%, which provides accurate current feedback for high-performance motor control.
21 December 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
A novel amplitude-domain pulse-width modulation (AD-PWM) technique for three-phase energy stored quasi-Z-source (ES-qZSI) photovoltaic (PV) power system is proposed in this paper. The proposed modulation technique performs switching states and shoot-through behavior based on the relationship of size among three-phase voltages, showing the attractiveness of extreme simplicity and low computation. This paper further investigates the AD-PWM based three-phase PV power system. An active power control method integrated with reactive power compensation for the system in natural coordinate to avoid complicated calculation of trigonometric function. As a result, active power regulation integrated with reactive power compensation is fast and reliable. Compare with the state-of-arts of control schemes for ES-qZSI system utilizing techniques, the proposed control strategy has advantages: 1) The computation is low because there is no shoot-through reference and avoiding complexity vector calculation; 2) there is a reliable capability of ensuring the grid-injected current tracking the grid voltage in phase, owing to the reactive power generated by reactive power equipment is taken into account to control the ES-qZSI’s output current. Simulation and experimental results verify the outstanding features of the proposed AD-PWM and active power control strategy integrated with the reactive power compensation technique for three-phase ES-qZSI PV power system.