Rui Sergio Monteiro de Barros

Rui Sergio Monteiro de Barros

Auto-generated profile, based on publicly available information

Rui Sergio Monteiro de Barros

Hospital Porto Dias, Brasil; Universidade do Estado do Pará, Brazil

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2011 in Journal of Reconstructive Microsurgery
Verified
Journal Article
Closed access
RBRui S.M. Barros
Rui S.M. Barros
MBMarcus V Brito
Marcus V Brito
GMGiovanna P Moura
Giovanna P Moura
MMMarina P Moura
Marina P Moura
LFLívia M Freitas
Lívia M Freitas
RLRafael Aquino Leal
Rafael Aquino Leal
An alternative method of magnification for microvascular anastomosis was analyzed using an ordinary video camera and compared with the traditional method under microscope. For this study 20 rats were divided in two groups of 10 each: control group (microscope-assisted [M]) and experimental group (video-assisted [V]). Magnification was accomplished by a surgical microscope in group M, whereas a video system composed of low-cost camera, audiovisual cable, and analogue television in group V. In both groups, the right femoral artery was severed and sutured with interrupted simple stitches. The criteria examined were: patency, vessel diameter, amount of sutures, anastomosis time, and histologic features. There were no differences between both groups in patency rate and vessel diameter. The video-assisted microanastomosis is a time-consuming procedure as compared with the microscope-assisted anastomosis, to a certain extent due to lack of stereoscopic image and technical inability with the video system as well. There was a smaller quantity of sutures in group V. Higher foreign body tissue reaction was found in group M, consequent to greater amount of suture material. In conclusion, video-assisted microanastomosis is possible with the present video system but is not as safe as conventional microanastomosis.

1 January 2022 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
RBRui Sergio Monteiro de Barros
Rui Sergio Monteiro de Barros
DSDeivid Ramos dos Santos
Deivid Ramos dos Santos
RTRenan Kleber Costa Teixeira
Renan Kleber Costa Teixeira
NANayara Pontes de Araújo
Nayara Pontes de Araújo
DSDanusa Neves Somensi
Danusa Neves Somensi
ACAtylla de Andrade Candido
Atylla de Andrade Candido
To study the anatomorphometry of the plexus brachialis (PB) of rats under a high-definition video system. Ten male Wistar rats discarded from other research that did not interfere in the morphology of the animal, respecting the principle of reduction, were used. All animals were submitted to the same protocol. Initially, the cervical region was shaved. The animals were placed in a dorsal position. A single elbow-to-elbow incision was performed and dissection started at the deltopectoral sulcus. The procedures were performed under a video system. To measure the structures, the Image J software was used. All the PB evaluated originated from the C5-T1 spinal nerves. C5 and C6 converged to form the truncus superior, the root of C7 originated the truncus medius, and the confluence of C8 and T1 originated the truncus inferior. It was found the union of C7, C8, and T1 to form truncus inferomedialis instead of separate medial and inferior truncus. C8 (1.31 mm) was the thickest root, the truncus inferior (1.80 mm) and the nerve radialis (1.02 mm), were the thickest. The anatomy of the PB is comparable to humans, admitting variations. The videomagnification system is useful to perform microsurgical dissection.

1 January 2023 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
TSThiago Victal Saliba
Thiago Victal Saliba
RBRui Sérgio Monteiro de Barros
Rui Sérgio Monteiro de Barros
To present and validate a new simulation model for endoscopic phonomicrosurgery training as an improved teaching method. A low-cost artificial model was assembled using 3D printing, silicone, and gelatin. The study was designed to test the model's ability to carry out training and teaching of endoscopic phonomicrosurgery. The synthetic model was built to simulate normal and pathological vocal folds such as polyps, intracordal cysts and keratoses, made of silicone and gelatin and embedded in a larynx framework made by 3D printing. Simulations of endoscopic surgical procedures were performed and documented through photographs and videos and the images were submitted to the evaluation of a group of 17 otorhinolaryngologists who used a Likert scale questionnaire. The responses were submitted to an agreement analysis using the sum of the scores obtained for the responses as an appropriate level of validation. Cronbach's alpha index was calculated to measure the degree of the questionnaire internal consistency. The evaluations indicated maximum approval for the model adequacy for use in practical classes and for the teaching of the procedures, as well as in the overall satisfaction with the model in the use of surgical training. The present proposal for training laryngeal endoscopic surgery in a 3D synthetic model is a viable option according to the validation methodology used in the present study.

1 January 2021 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
DSDeivid Ramos dos Santos
Deivid Ramos dos Santos
RTRenan Kleber Costa Teixeira
Renan Kleber Costa Teixeira
NANayara Pontes de Araújo
Nayara Pontes de Araújo
FCFaustino Chaves Calvo
Faustino Chaves Calvo
TDTiago Braga Duarte
Tiago Braga Duarte
RBRui Sergio Monteiro de Barros
Rui Sergio Monteiro de Barros
To describe a new anesthetic protocol medullary and nerve roots access and in Rattus norvegicus. Seventy female Wistar rats (n=70) were used. The animals were randomly divided into two laminectomy groups: cervical (n=40) and thoracic (n=30). In cervical group, a right posterior hemilaminectomy was performed to access the nerve roots. In thoracic group, a laminectomy of the eighth thoracic vertebra was accomplished. Thirty-five rats (20 cervical and 15 thoracic) were submitted to old anesthetic protocol (ketamine 70 mg/kg plus xylazine 10 mg/kg); and the 35 other animals (20 cervical and 15 thoracic) were submitted to a new anesthetic protocol (ketamine 60 mg/kg,xylazine 8 mg/kg and fentanyl 0.03 mg/kg). The time to complete induction was 4.15 ±1.20 minin ketamine, xylazine and fentanyl group, and it was 4.09 ±1.47 min in the ketamine and xylazine group. There was no correlation in the time required to perform the cervical laminectomy in the old anesthetic protocol. In all groups, the animals submitted to the old anesthetic protocol had a higher level of pain on the first and third postoperative days than the animals submitted to the new anesthetic protocol. The new anesthetic protocol reduces the surgical time, allows better maintenance of the anesthetic plan, and brings more satisfactory postoperative recovery.

1 January 2020 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
RTRenan Kleber Costa Teixeira
Renan Kleber Costa Teixeira
FCFaustino Chaves Calvo
Faustino Chaves Calvo
DSDeivid Ramos dos Santos
Deivid Ramos dos Santos
NANayara Pontes de Araújo
Nayara Pontes de Araújo
DTDaniela Ferreira Tramontin
Daniela Ferreira Tramontin
RBRui Sergio Monteiro de Barros
Rui Sergio Monteiro de Barros
Better magnification microscopes, advances in anatomic knowledge of peripheral nerves topography and a better understanding of the pathophysiology of nerve injury have all led to a decisive leap forward in the management of this condition 3 , 4 . Refined microsurgical techniques 5 , 6 such as neurorrhaphies (end-to-end, end-to-side, side-to-side, supercharging), neural neurotization, nerve transfer, nerves conduits, and others were developed; However, despite the encouraging results obtained when analyzing the technical, histological and electrophysiological parameters; these parameters normally do not correlate with the return of the functional recovery 3 , 5 , 7 , 8 , making the treatment of peripheral nerve injury a challenge to actual medicine.

1 January 2022 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
MPMarcela Maria Rabelo Pinto
Marcela Maria Rabelo Pinto
DSDeivid Ramos dos Santos
Deivid Ramos dos Santos
LBLívia Guerreiro de Barros Bentes
Lívia Guerreiro de Barros Bentes
RLRafael Silva Lemos
Rafael Silva Lemos
NANyara Rodrigues Conde de Almeida
Nyara Rodrigues Conde de Almeida
RBRui Sergio Monteiro de Barros
Rui Sergio Monteiro de Barros
To describe the microsurgical anatomical aspects of the extratemporal facial nerve of Wistar rats under a high-definition video system. Ten male Wistar rats (12–15 weeks old), without veterinary diseases, weighing 220–280 g, were used in this study. All animals in this study were submitted to the same protocol and by the same surgeon. A 10-mm incision was made below the bony prominence of the right or left ear, and extended towards the angle of the mandible. The dissection was performed and the main branches of the facial nerve were dissected. The main trunk of the facial nerve has a length of 0.88 ± 0.10 mm and a length of 3.81 ± 1.03 mm, measured from its emergence from the stylomastoid foramen to its bifurcation. Seven branches originating from the facial nerve were identified: posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic. The anatomy of the facial nerve is comparable to that of humans, with some variations. The most observed anatomical division was the distribution in posterior auricular, posterior cervical, cervical, mandibular, buccal, temporal, and zygomatic branches. There is no statistical difference between the thickness and distance of the structures compared to the contralateral side.