Takashi Abe

Takashi Abe

Auto-generated profile, based on publicly available information

Takashi Abe

International Institute for Integrative Sleep Medicine (WPI-IIIS), University of Tsukuba, Tsukuba, Ibaraki, Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in SLEEP Advances
Verified
Journal Article
Open access
PDF file
TATakashi Abe
Takashi Abe
Drowsiness associated with sleep loss and circadian misalignment is a risk factor for accidents and human error. The percentage of time that the eyes are more than 80% closed (PERCLOS) is one of the most validated indices used for the passive detection of drowsiness, which is increased with sleep deprivation, after partial sleep restriction, at nighttime, and by other drowsiness manipulations during vigilance tests, simulated driving, and on-road driving. However, some cases have been reported wherein PERCLOS was not affected by drowsiness manipulations, such as in moderate drowsiness conditions, in older adults, and during aviation-related tasks. Additionally, although PERCLOS is one of the most sensitive indices for detecting drowsiness-related performance impairments during the psychomotor vigilance test or behavioral maintenance of wakefulness test, no single index is currently available as an optimal marker for detecting drowsiness during driving or other real-world situations. Based on the current published evidence, this narrative review suggests that future studies should focus on: (1) standardization to minimize differences in the definition of PERCLOS between studies; (2) extensive validation using a single device that utilizes PERCLOS-based technology; (3) development and validation of technologies that integrate PERCLOS with other behavioral and/or physiological indices, because PERCLOS alone may not be sufficiently sensitive for detecting drowsiness caused by factors other than falling asleep, such as inattention or distraction; and (4) further validation studies and field trials targeting sleep disorders and trials in real-world environments. Through such studies, PERCLOS-based technology may contribute to preventing drowsiness-related accidents and human error.

28 November 2020 in Nutrients
Verified
Journal Article
Open access
PDF file
SZSimeng Zhang
Simeng Zhang
JTJiro Takano
Jiro Takano
NMNorihito Murayama
Norihito Murayama
MTMorie Tominaga
Morie Tominaga
TATakashi Abe
Takashi Abe
Kumpei TokuyamaKumpei Tokuyama
Kumpei Tokuyama
Ingesting oolong tea or caffeine acutely increases energy expenditure, and oolong tea, but not caffeine, stimulates fat oxidation. The acute effects of caffeine, such as increased heart rate and interference with sleep, diminish over 1–4 days, known as caffeine tolerance. During each 14-day session of the present study, 12 non-obese males consumed oolong tea (100 mg caffeine, 21.4 mg gallic acid, 97 mg catechins and 125 mg polymerized polyphenol), caffeine (100 mg), or placebo at breakfast and lunch. On day 14 of each session, 24-h indirect calorimetry and polysomnographic sleep recording were performed. Caffeine and oolong tea increased fat oxidation by ~20% without affecting energy expenditure over 24-h. The decrease in the respiratory quotient by oolong tea was greater than that by caffeine during sleep. The effect of oolong tea on fat oxidation was salient in the post-absorptive state. These findings suggest a role of unidentified ingredients in oolong tea to stimulate fat oxidation, and this effect is partially suppressed in a postprandial state. Two weeks of caffeine or oolong tea ingestion increased fat oxidation without interfering with sleep. The effects of subacute ingestion of caffeine and oolong tea differed from the acute effects, which is a particularly important consideration regarding habitual tea consumption.

10 February 2020 in SLEEP
Verified
Journal Article
Open access
PDF file
TATakashi Abe
Takashi Abe
KMKazuo Mishima
Kazuo Mishima
SKShingo Kitamura
Shingo Kitamura
AHAkiko Hida
Akiko Hida
YIYuichi Inoue
Yuichi Inoue
KOKatsuhiko Ogata
Katsuhiko Ogata
Vigilance deficits account for a substantial number of accidents and errors. Current techniques to detect vigilance impairment measure only the most severe level evident in eyelid closure and falling asleep, which is often too late to avoid an accident or error. The present study sought to identify ocular biometrics of intermediate impairment of vigilance and develop a new technique that could detect a range of deficits in vigilant attention (VA). Sixteen healthy adults performed well-validated Psychomotor Vigilance Test (PVT) for tracking vigilance attention while undergoing simultaneous recording of eye metrics every 2 hours during 38 hours of continuous wakefulness. A novel marker was found that measured VA when the eyes were open—the prevalence of microsaccades. Notably, the prevalence of microsaccades decreased in response to sleep deprivation and time-on-task. In addition, a novel algorithm for detecting multilevel VA was developed, which estimated performance on the PVT by integrating the novel marker with other eye-related indices. The novel algorithm also tracked changes in intermediate level of VA (specific reaction times in the PVT, i.e. 300–500 ms) during prolonged time-on-task and sleep deprivation, which had not been tracked previously by conventional techniques. The implication of the findings is that this novel algorithm, named “eye-metrical estimation version of the PVT: PVT-E,” can be used to reduce human-error-related accidents caused by vigilance impairment even when its level is intermediate.


30 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZFZhiwei Fan
Zhiwei Fan
YZYunyao Zhu
Yunyao Zhu
CSChihiro Suzuki
Chihiro Suzuki
YSYoko Suzuki
Yoko Suzuki
YWYumi Watanabe
Yumi Watanabe
TATakashi Abe
Takashi Abe
Binaural beats can entrain neural oscillations and modulate behavioral states. However, the effect of binaural beats, particularly those with slow frequencies (< 1 Hz), on sleep remains poorly understood. We hypothesized that 0.25-Hz beats can entrain neural oscillations and enhance slow-wave sleep by shortening its latency or increasing its duration. To investigate this, we included 12 healthy participants (six women; mean age, 25.4 ± 2.6 years) who underwent four 90-min afternoon nap sessions, comprising a sham condition (without acoustic stimulation) and three binaural-beat conditions (0, 0.25, or 1 Hz) with a 250-Hz carrier tone. The acoustic stimuli, delivered through earphones, were sustained throughout the 90-min nap period. Both N2- and N3- latencies were shorter in the 0.25-Hz binaural beats condition than in the sham condition. We observed no significant results regarding neural entrainment at slow frequencies, such as 0.25 and 1 Hz, and the modulation of sleep oscillations, including delta and sigma activity, by binaural beats. In conclusion, this study demonstrated the potential of binaural beats at slow frequencies, specifically 0.25 Hz, for inducing slow-wave sleep in generally healthy populations.

1 January 2025 in BioMed Research International
Verified
Journal Article
Open access
LMLuis Alfredo Moctezuma
Luis Alfredo Moctezuma
MMMarta Molinas
Marta Molinas
TATakashi Abe
Takashi Abe
Research suggests that dreams play a role in the regulation of emotional processing and memory consolidation; electroencephalography (EEG) is useful for studying them, but manual annotation is time‐consuming and prone to bias. This study was aimed at developing an EEG‐based machine learning (ML) model to automatically identify dream and dreamless states in sleep. We extracted features from EEG data using common spatial patterns (CSPs) and the discrete wavelet transform (DWT) and used them to classify EEG signals into dream and dreamless states using ML models. To determine the most informative channels for classification, we used the permutation‐based channel selection method and the nondominated sorting genetic algorithm II (NSGA‐II). We evaluated our proposal using a public dataset that is part of the DREAM project, which was collected from 58 EEG channels during rapid eye movement (REM) and non‐REM sleep, while 28 subjects reported dream or dreamless experiences. We achieved accuracies greater than 0.85 to distinguish dream and dreamless states using CSP‐based feature extraction combined with k ‐nearest neighbors (KNN), as well as through multiple combinations of EEG channels identified by channel selection methods. Our findings suggest that as few as 8–10 EEG channels may be sufficient for dream recognition. Excluding one subject at a time during model training revealed challenges in generalizing the models to unseen subjects. Channel selection methods have proven to be effective in selecting relevant subsets of EEG channels to classify dreams and dreamless experiences. Our results demonstrate the feasibility of automatic dream detection and highlight the need to improve ML generalization.