Cassandra L. Hays

Cassandra L. Hays

Auto-generated profile, based on publicly available information

Cassandra L. Hays

Truhlsen Eye Institute, Durham Research Center I, University of Nebraska Medical Center, Omaha, NE 68198-5840

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
VGVikas Gulati
Vikas Gulati
SFShan Fan
Shan Fan
CHCassandra L. Hays
Cassandra L. Hays
TSThomas W. Samuelson
Thomas W. Samuelson
IAIqbal Ike K. Ahmed
Iqbal Ike K. Ahmed
CTCarol Toris
Carol Toris
Purpose.: To study the effect on outflow facility and outflow resistance of a nitinol microstent implanted into Schlemm's canal. Methods.: Using a constant pressure perfusion method, outflow facility and outflow resistance were measured in 26 pairs of dissected anterior segments from donated human eyes. Measurements were made at perfusion pressures of 10, 20, 30 and 40 mm Hg. The Hydrus Microstent was placed in Schlemm's canal of one eye and the contralateral eye underwent a sham procedure. Outflow facility and outflow resistance were measured again after the microstent implantation or sham procedure. Results.: The Hydrus Microstent significantly increased outflow facility from 0.33 ± 0.17 μL/min/mm Hg to 0.52 ± 0.19 μL/min/mm Hg (P < 0.001). Outflow resistance was significantly reduced from 4.38 ± 3.03 mm Hg/μL/min at baseline to 2.34 ± 1.04 mm Hg/μL/min (P < 0.001) with the microstent. There was a linear correlation between outflow resistance at baseline and decrease in outflow resistance with the microstent (R 2 = 0.89, P < 0.0001). Conclusions.: The increase in outflow facility and decrease in resistance supports the potential use of the Hydrus Microstent as a surgical option to reduce intraocular pressure (IOP). The IOP-lowering effect may be higher in eyes with higher outflow resistance (and IOP) as compared with eyes with lower outflow resistance (and IOP).

1 March 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
CHCassandra L. Hays
Cassandra L. Hays
VGVikas Gulati
Vikas Gulati
SFShan Fan
Shan Fan
TSThomas W. Samuelson
Thomas W. Samuelson
IAIqbal Ike K. Ahmed
Iqbal Ike K. Ahmed
CTCarol Toris
Carol Toris
Purpose. To determine improvement in outflow facility (C) in human anterior segments implanted with a novel Schlemm's canal scaffold or two trabecular micro-bypasses. Methods. Human anterior segments were isolated from 12 pairs of eyes from donors with no history of ocular disease and then perfused at 50, 40, 30, 20, and 10 mm Hg pressures for 10 minutes each. Baseline C was calculated from perfusion pressures and flow rates. The scaffold was implanted into Schlemm's canal of one anterior segment, and two micro-bypasses were implanted three clock-hours apart in the contralateral anterior segment. Outflow facility and resistance were compared at various standardized perfusion pressures and between each device. Results. Compared to baseline, C increased by 0.16 ± 0.12 μL/min/mm Hg (74%) with the scaffold, and 0.08 ± 0.12 μL/min/mm Hg (34%) with two micro-bypasses. The scaffold increased C at perfusion pressures of 50, 40, 30, and 20 mm Hg (P < 0.005). Two micro-bypasses increased C at a perfusion pressure of 40 mm Hg (P < 0.05). Conclusions. Both implants effectively increased C in human eyes ex vivo. The scaffold increased C by a greater percentage (73% vs. 34%) and at a greater range of perfusion pressures (20 to 50 mm Hg vs. 40 mm Hg) than the two micro-bypasses, suggesting that the 8-mm dilation of Schlemm's canal by the scaffold may have additional benefits in lowering the outflow resistance. The Hydrus Microstent scaffold may be an effective therapy for increasing outflow facility and thus reducing the IOP in patients with glaucoma.

7 June 2019 in eLife
Verified
Journal Article
Open access
JGJustin J Grassmeyer
Justin J Grassmeyer
ACAsia L Cahill
Asia L Cahill
CHCassandra L Hays
Cassandra L Hays
CBCody Barta
Cody Barta
RQRolen M Quadros
Rolen M Quadros
WTWallace B. Thoreson
Wallace B. Thoreson
To encode light-dependent changes in membrane potential, rod and cone photoreceptors utilize synaptic ribbons to sustain continuous exocytosis while making rapid, fine adjustments to release rate. Release kinetics are shaped by vesicle delivery down ribbons and by properties of exocytotic Ca2+ sensors. We tested the role for synaptotagmin-1 (Syt1) in photoreceptor exocytosis by using novel mouse lines in which Syt1 was conditionally removed from rods or cones. Photoreceptors lacking Syt1 exhibited marked reductions in exocytosis as measured by electroretinography and single-cell recordings. Syt1 mediated all evoked release in cones, whereas rods appeared capable of some slow Syt1-independent release. Spontaneous release frequency was unchanged in cones but increased in rods lacking Syt1. Loss of Syt1 did not alter synaptic anatomy or reduce Ca2+ currents. These results suggest that Syt1 mediates both phasic and tonic release at photoreceptor synapses, revealing unexpected flexibility in the ability of Syt1 to regulate Ca2+-dependent synaptic transmission.

1 February 2020 in Biophysical Journal
Verified
Journal Article
Closed access
CHCassandra L. Hays
Cassandra L. Hays
JGJustin J. Grassmeyer
Justin J. Grassmeyer
XWXiangyi Wen
Xiangyi Wen
RJRoger Janz
Roger Janz
RHRuth Heidelberger
Ruth Heidelberger
WTWallace B. Thoreson
Wallace B. Thoreson

26 March 2021 in eLife
Verified
Journal Article
Open access
CHCassandra L Hays
Cassandra L Hays
ASAsia L Sladek
Asia L Sladek
GFGreg D Field
Greg D Field
WTWallace B. Thoreson
Wallace B. Thoreson
Vision under starlight requires rod photoreceptors to transduce and transmit single-photon responses to the visual system. Small single-photon voltage changes must therefore cause detectable reductions in glutamate release. We found that rods achieve this by employing mechanisms that enhance release regularity and its sensitivity to small voltage changes. At the resting membrane potential in darkness, mouse rods exhibit coordinated and regularly timed multivesicular release events, each consisting of ~17 vesicles and occurring two to three times more regularly than predicted by Poisson statistics. Hyperpolarizing rods to mimic the voltage change produced by a single photon abruptly reduced the probability of multivesicular release nearly to zero with a rebound increase at stimulus offset. Simulations of these release dynamics indicate that this regularly timed, multivesicular release promotes transmission of single-photon responses to post-synaptic rod-bipolar cells. Furthermore, the mechanism is efficient, requiring lower overall release rates than uniquantal release governed by Poisson statistics.

11 November 2020 in Journal of General Physiology
Verified
Journal Article
Open access
PDF file
CHCassandra L. Hays
Cassandra L. Hays
ASAsia L. Sladek
Asia L. Sladek
WTWallace B. Thoreson
Wallace B. Thoreson
The vertebrate visual system can detect and transmit signals from single photons. To understand how single-photon responses are transmitted, we characterized voltage-dependent properties of glutamate release in mouse rods. We measured presynaptic glutamate transporter anion current and found that rates of synaptic vesicle release increased with voltage-dependent Ca2+ current. Ca2+ influx and release rate also rose with temperature, attaining a rate of ∼11 vesicles/s/ribbon at −40 mV (35°C). By contrast, spontaneous release events at hyperpolarized potentials (−60 to −70 mV) were univesicular and occurred at random intervals. However, when rods were voltage clamped at −40 mV for many seconds to simulate maintained darkness, release occurred in coordinated bursts of 17 ± 7 quanta (mean ± SD; n = 22). Like fast release evoked by brief depolarizing stimuli, these bursts involved vesicles in the readily releasable pool of vesicles and were triggered by the opening of nearby ribbon-associated Ca2+ channels. Spontaneous release rates were elevated and bursts were absent after genetic elimination of the Ca2+ sensor synaptotagmin 1 (Syt1). This study shows that at the resting potential in darkness, rods release glutamate-filled vesicles from a pool at the base of synaptic ribbons at low rates but in Syt1-dependent bursts. The absence of bursting in cones suggests that this behavior may have a role in transmitting scotopic responses.