13 November 2023 in IEEE Transactions on Applied Superconductivity
The SPARC Toroidal Field Model Coil (TFMC) Program was a three-year effort between 2018 and 2021 that developed novel rare earth barium copper oxide (REBCO) superconductor technologies and then successfully utilized these technologies to design, build, and test a first-in-class, high-field (∼20 T), representative-scale (∼3 m) superconducting toroidal field (TF) coil. The program was executed jointly by the MIT Plasma Science and Fusion Center (PSFC) and Commonwealth Fusion Systems (CFS) as a technology enabler of the superconducting high-field pathway to fusion energy, and, in particular, as a risk retirement program for the no insulation (NI) TF magnet in the SPARC net-energy fusion tokamak. The TFMC achieved its programmatic goal of experimentally demonstrating a large-scale high-field REBCO magnet, achieving 20.1 T peak field-on-conductor with 40.5 kA of terminal current, 815 kN/m of Lorentz loading on the REBCO stacks, and almost 1 GPa of mechanical stress accommodated by the structural case. Fifteen internal demountable pancake-to-pancake joints operated in the 0.5 to 2.0 nΩ range at 20 K and in magnetic fields up to 12 T. The dc and ac electromagnetic performance of the magnet predicted by new advances in high-fidelity computational models was confirmed in two test campaigns while the parallel, single-pass, pressure-vessel style coolant scheme capable of large heat removal was validated. In the test facility, a feeder system composed of REBCO current leads and cables was experimentally qualified up to 50 kA, and a liquid-free cryocooler-based helium cryogenic system provided 600 W of cooling power at 20 K with mass flow rates up to 70 g/s at a maximum design pressure of 2 MPa for the test campaigns. Finally, the feasibility of using passive, self-protection against a quench in a fusion-scale NI TF coil was experimentally assessed. While the TFMC was intentionally not optimized for quench resiliency—and suffered localized thermal damage in response to an intentional open-circuit quench at 31.5 kA terminal current—the extensive data and validated models that it produced represent a critical step towards this important objective.
1 March 2022 in Nuclear Fusion
The SPARC tokamak project, currently in engineering design, aims to achieve breakeven and burning plasma conditions in a compact device, thanks to new developments in high-temperature superconductor technology. With a magnetic field of 12.2 T on axis and 8.7 MA of plasma current, SPARC is predicted to produce 140 MW of fusion power with a plasma gain of Q ≈ 11, providing ample margin with respect to its mission of Q > 2. All tokamak systems are being designed to produce this landmark plasma discharge, thus enabling the study of burning plasma physics and tokamak operations in reactor relevant conditions to pave the way for the design and construction of a compact, high-field fusion power plant. Construction of SPARC is planned to begin by mid-2021.
23 July 2019 in Nuclear Fusion
18 June 2018 in Plasma Physics and Controlled Fusion
Using data-driven methodology, we exploit the time series of relevant plasma parameters for a large set of disrupted and non-disrupted discharges to develop a classification algorithm for detecting disruptive phases in shots that eventually disrupt. Comparing the same methodology on different devices is crucial in order to have information on the portability of the developed algorithm and the possible extrapolation to ITER. Therefore, we use data from two very different tokamaks, DIII-D and Alcator C-Mod. We focus on a subset of disruption predictors, most of which are dimensionless and/or machine-independent parameters, coming from both plasma diagnostics and equilibrium reconstructions, such as the normalized plasma internal inductance ℓ
i
and the n = 1 mode amplitude normalized to the toroidal magnetic field. Using such dimensionless indicators facilitates a more direct comparison between DIII-D and C-Mod. We then choose a shallow Machine Learning technique, called Random Forests, to explore the databases available for the two devices. We show results from the classification task, where we introduce a time dependency through the definition of class labels on the basis of the elapsed time before the disruption (i.e. ‘far from a disruption’ and ‘close to a disruption’). The performances of the different Random Forest classifiers are discussed in terms of several metrics, by showing the number of successfully detected samples, as well as the misclassifications. The overall model accuracies are above 97% when identifying a ‘far from disruption’ and a ‘disruptive’ phase for disrupted discharges. Nevertheless, the Forests are intrinsically different in their capability of predicting a disruptive behavior, with C-Mod predictions comparable to random guesses. Indeed, we show that C-Mod recall index, i.e. the sensitivity to a disruptive behavior, is as low as 0.47, while DIII-D recall is ∼0.72. The portability of the developed algorithm is also tested across the two devices, by using DIII-D data for training the forests and C-Mod for testing and vice versa.
29 September 2020 in Journal of Plasma Physics
SPARC is being designed to operate with a normalized beta of $\beta _N=1.0$ , a normalized density of $n_G=0.37$ and a safety factor of $q_{95}\approx 3.4$ , providing a comfortable margin to their respective disruption limits. Further, a low beta poloidal $\beta _p=0.19$ at the safety factor $q=2$ surface reduces the drive for neoclassical tearing modes, which together with a frozen-in classically stable current profile might allow access to a robustly tearing-free operating space. Although the inherent stability is expected to reduce the frequency of disruptions, the disruption loading is comparable to and in some cases higher than that of ITER. The machine is being designed to withstand the predicted unmitigated axisymmetric halo current forces up to 50 MN and similarly large loads from eddy currents forced to flow poloidally in the vacuum vessel. Runaway electron (RE) simulations using GO+CODE show high flattop-to-RE current conversions in the absence of seed losses, although NIMROD modelling predicts losses of ${\sim }80$ %; self-consistent modelling is ongoing. A passive RE mitigation coil designed to drive stochastic RE losses is being considered and COMSOL modelling predicts peak normalized fields at the plasma of order $10^{-2}$ that rises linearly with a change in the plasma current. Massive material injection is planned to reduce the disruption loading. A data-driven approach to predict an oncoming disruption and trigger mitigation is discussed.
7 March 2018 in Fusion Science and Technology
Using data-driven methodology, we exploit the time series of relevant plasma parameters for a large set of disrupted and non-disrupted discharges from the DIII-D tokamak with the objective of developing a disruption classification algorithm. We focus on a subset of disruption predictors, most of which are dimensionless and/or machine-independent parameters such as the plasma internal inductance and the Greenwald density fraction , coming from both plasma diagnostics and equilibrium reconstructions. The utilization of dimensionless indicators will facilitate a more direct comparison between different tokamak devices. In order to eventually develop a robust disruption warning algorithm, we leverage Machine Learning techniques, and in particular, we choose the Random Forests algorithm to explore the DIII-D database. We show the results coming from both binary (disrupted/non-disrupted) and multiclass classification problems. In the latter, the time dependency is introduced through the definition of class labels on the basis of the elapsed time before the disruption (i.e., ‘far from a disruption’, ‘within 350 ms of disruption’, etc.). Depending on the formulation of the problem, overall disruption prediction accuracy up to 90% is demonstrated, approaching 97% when identifying a stable and a disruptive phase for disrupted discharges. The performances of the different Random Forest classifiers are discussed in terms of accuracy, by showing the percentages of successfully detected samples, together with the false positive and false negative rates.