1 April 2013 in Revista Latino-Americana de Enfermagem
KGKazuko Uchikawa Graziano
FPFlávia Morais Gomes Pinto
Flávia Morais Gomes Pinto
RSRafael Queiroz de Souza
OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v) using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440) and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.
1 December 2012 in Revista da Escola de Enfermagem da USP
A antissepsia cirúrgica das mãos visa à prevenção de infecções do sítio cirúrgico, importante causa de morbimortalidade pós-operatória e aumento dos custos hospitalares. Este estudo teve como objetivo comparar a eficácia de preparações alcoólicas com os produtos tradicionais na antissepsia cirúrgica das mãos por meio de uma revisão sistemática da literatura. Foram considerados estudos primários ou secundários, tendo como desfecho a contagem microbiana das mãos ou taxas de infecções do sítio cirúrgico. A busca foi realizada no Portal BVS, PubMed, Ask e MEDLINE. Foram selecionados 25 estudos (2 revisões sistemáticas, 19 experimentais e 4 de coorte). As preparações alcoólicas tiveram uma redução microbiana igual e/ou maior aos produtos tradicionais em 17 estudos e inferior em 4; as taxas de infecções do sítio cirúrgico foram similares. Portanto, existem evidências científicas que suportam a segurança das preparações alcoólicas para antissepsia cirúrgica das mãos.
1 October 2011 in Revista da Escola de Enfermagem da USP
Estudo de revisão integrativa da literatura com o objetivo de buscar evidências que subsidiem a incorporação do ozônio como agente esterilizante de produtos para saúde. A busca foi realizada nas bases MEDLINE, SCOPUS, COCHRANE, COMPENDEX, INSPEC E ENGINEERING RESEARCH DATABASE, utilizando-se os descritores ozone e sterilization. Foram obtidas cinco publicações, entre 1990 e 2008, que testaram o ozônio como esterilizante. Todas utilizaram o mesmo tipo de investigação (experimental laboratorial) e alcançaram esterilização pelo ozônio, porém com variados escopos e produtos testados, além de diversos procedimentos metodológicos. Tendo em vista a incessante tecnologia de novos produtos, com ampla variedade de conformações e matéria-prima, os achados denotam o ozônio um método promissor, porém ainda em fase inicial de investigação. Mais estudos experimentais ainda são necessários, de maneira a subsidiar evidências mais amplas sobre suas possibilidades e limitações.
1 April 2011 in Revista Latino-Americana de Enfermagem
This experimental, comparative, laboratory study evaluated the effectiveness of the sterilization of single-use laparoscopic instruments - SULIs (grasper, dissector, scissors, Veress needle and electrosurgical probe system), after contamination-challenge with bacterial spores and sheep blood, and compared the results of the sterilization tests with those of the equivalent reusable instruments. The cleaning methods used were; ultrasonic washer with pulsatile water jet and enzymatic detergent, manual cleaning, cleaning with pressurized water and rinsing. The SULIs were sterilized with ethylene oxide and the reusable instruments in an autoclave. Sterility tests showed 100% negative results for recovery of contaminate microorganisms in both groups. It was concluded that, regarding the sterilization, that it is possible to reprocess SULIs.
1 August 2010 in Revista Latino-Americana de Enfermagem
Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.
1 June 2007 in Revista Latino-Americana de Enfermagem
SPSilma Maria Cunha Pinheiro
Silma Maria Cunha Pinheiro
The new low-temperature sterilization technologies are presented as an alternative to the use of ethylene oxide. This review was performed in order to identify evidences of the antimicrobial activity, toxicity, adverse events and the applicability of these technologies. The research was carried through the electronic databases MEDLINE and LILACS up to 2005. The authors analyzed 10 articles in this survey. The studies about the efficacy of these sterilization methods constitute experimental and comparative research that showed the influence of the extension and diameter of the lumen, besides the presence of crystal salts. Thus, choosing the correct equipment is essential, as well as the assurance of the cleansing of the devices, which interfere with the effectiveness of the low-temperature sterilization. These technologies present limitations regarding the sterilization of graft bone and affect the materials properties.