Laboratory of Electrical Systems, Energy Efficiency and Telecommunications, Faculty of Science and Technology, Cadi Ayyad University, Marrakesh, Morocco
Auto-generated profile, based on publicly available information
Zahra Bouzidi
Laboratory of Electrical Systems, Energy Efficiency and Telecommunications, Faculty of Science and Technology, Cadi Ayyad University, Marrakesh, Morocco
This paper presents an analysis of the radiated susceptibility of multiconductor shielded cables within complex structures following a hybrid method using moments (MoM) circuit models. The MoM code was used to compute the currents on the shielding induced by an external electromagnetic field and incorporated into a circuit model. The proposed method can be employed for nonlinear loads. The method was tested on two cases: coaxial shielded cables inside a cavity and a car with complex wiring, including a coaxial cable, a twinax cable (a cable with two parallel wires), and a triaxial cable (a cable with three parallel wires), all of which are excited by an incident plane wave. The proposed method provides high accuracy and significant speed gain, and its results are in good agreement with those obtained in other studies.
The primary objective of this paper is to model transmission lines with frequency-dependent parameters loaded with linear and nonlinear terminations using an approach based on Pade approximations. To validate our algorithm in the case of lines with constant losses and frequency-dependent parameters, examples of applications in the time and frequency domains are presented. The simulations and obtained results are reported and analysed.