Romain Froidevaux

Romain Froidevaux

Auto-generated profile, based on publicly available information

Romain Froidevaux

Institute for Biomedical Engineering ETH Zurich and University of Zurich Zurich Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in NeuroImage
Verified
Journal Article
Open access
MWMarkus Weiger
Markus Weiger
RFRomain Froidevaux
Romain Froidevaux
EBEmily Louise Baadsvik
Emily Louise Baadsvik
DBDavid Otto Brunner
David Otto Brunner
MRManuela Barbara Rösler
Manuela Barbara Rösler
KPKlaas Paul Pruessmann
Klaas Paul Pruessmann
Myelin plays a key role in the function of the central nervous system and is involved in many neurodegenerative diseases. Hence, depiction of myelin is desired for both research and diagnosis. However, MRI of the lipid bilayer constituting the myelin membrane is hampered by extremely rapid signal decay and cannot be accomplished with conventional sequences. Dedicated short-T2 techniques have therefore been employed, yet with extended sequence timings not well matched to the rapid transverse relaxation in the bilayer, which leads to signal loss and blurring. In the present work, capture and encoding of the ultra-short-T2 signals in the myelin bilayer is considerably improved by employing advanced short-T2 methodology and hardware, in particular a high-performance human-sized gradient insert. The approach is applied to tissue samples excised from porcine brain and in vivo in a human volunteer. It is found that the rapidly decaying non-aqueous components in the brain can indeed be depicted with MRI at useful resolution. As a considerable fraction of these signals is related to the myelin bilayer, the presented approach has strong potential to contribute to myelin research and diagnosis.

23 February 2021 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
RFRomain Froidevaux
Romain Froidevaux
MWMarkus Weiger
Markus Weiger
MRManuela B. Rösler
Manuela B. Rösler
DBDavid O. Brunner
David O. Brunner
KPKlaas P. Pruessmann
Klaas P. Pruessmann
The aim of this work was to improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short‐T2 components at large dead‐time gaps. ZTE MRI with hybrid filling (HYFI) is a strategy for retrieving inner k‐space data missed during the dead‐time gaps arising from radio‐frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k‐space with a small single‐point‐imaging core surrounded by a stack of shells acquired on radial readouts in an onion‐like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in vitro and in vivo imaging, with an emphasis on comparison with the pointwise encoding time reduction with radial acquisition (PETRA) technique. Simulations predict higher SNR efficiency for HYFI compared with PETRA at preserved image quality, with the advantage increasing with the size of the k‐space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar image quality could be reduced by 25% to 60%. The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE‐based pulse sequences, in particular for large k‐space gaps. Promising applications include direct imaging of ultrashort‐T2 components, such as the myelin bilayer or collagen, T2 mapping of ultrafast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.

16 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RFRomain Froidevaux
Romain Froidevaux
MWMarkus Weiger
Markus Weiger
MRManuela B. Rösler
Manuela B. Rösler
DBDavid O. Brunner
David O. Brunner
BDBenjamin E. Dietrich
Benjamin E. Dietrich
KPKlaas P. Pruessmann
Klaas P. Pruessmann

3 January 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
EBEmily Louise Baadsvik
Emily Louise Baadsvik
MWMarkus Weiger
Markus Weiger
RFRomain Froidevaux
Romain Froidevaux
CSChristoph Michael Schildknecht
Christoph Michael Schildknecht
BIBenjamin Victor Ineichen
Benjamin Victor Ineichen
KPKlaas Paul Pruessmann
Klaas Paul Pruessmann
Purpose: To quantitatively map the myelin lipid‐protein bilayer in the live human brain.Methods: This goal was pursued by integrating a multi‐TE acquisition approach targeting ultrashort T2 signals with voxel‐wise fitting to a three‐component signal model. Imaging was performed at 3 T in two healthy volunteers using high‐performance RF and gradient hardware and the HYFI sequence. The design of a suitable imaging protocol faced substantial constraints concerning SNR, imaging volume, scan time, and RF power deposition. Model fitting to data acquired using the proposed protocol was made feasible through simulation‐based optimization, and filtering was used to condition noise presentation and overall depiction fidelity.Results: A multi‐TE protocol (11 TEs of 20–780 μs) for in vivo brain imaging was developed in adherence with applicable safety regulations and practical scan time limits. Data acquired using this protocol produced accurate model fitting results, validating the suitability of the protocol for this purpose. Structured, grainy texture of myelin bilayer maps was observed and determined to be a manifestation of correlated image noise resulting from the employed acquisition strategy. Map quality was significantly improved by filtering to uniformize the k‐space noise distribution and simultaneously extending the k‐space support. The final myelin bilayer maps provided selective depiction of myelin, reconciling competitive resolution (1.4 mm) with adequate SNR and benign noise texture.Conclusion: Using the proposed technique, quantitative maps of the myelin bilayer can be obtained in vivo. These maps offer unique information content with potential applications in basic research, diagnosis, disease monitoring, and drug development.

17 October 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
EBEmily Louise Baadsvik
Emily Louise Baadsvik
MWMarkus Weiger
Markus Weiger
RFRomain Froidevaux
Romain Froidevaux
WFWolfgang Faigle
Wolfgang Faigle
BIBenjamin Victor Ineichen
Benjamin Victor Ineichen
KPKlaas Paul Pruessmann
Klaas Paul Pruessmann
Purpose: To explore the properties of short‐T2 signals in human brain, investigate the impact of various experimental procedures on these properties and evaluate the performance of three‐component analysis.Methods: Eight samples of non‐pathological human brain tissue were subjected to different combinations of experimental procedures including D2O exchange and frozen storage. Short‐T2 imaging techniques were employed to acquire multi‐TE (33–2067 μs) data, to which a three‐component complex model was fitted in two steps to recover the properties of the underlying signal components and produce amplitude maps of each component. For validation of the component amplitude maps, the samples underwent immunohistochemical myelin staining.Results: The signal component representing the myelin bilayer exhibited super‐exponential decay with T2,min of 5.48 μs and a chemical shift of 1.07 ppm, and its amplitude could be successfully mapped in both white and gray matter in all samples. These myelin maps corresponded well to myelin‐stained tissue sections. Gray matter signals exhibited somewhat different components than white matter signals, but both tissue types were well represented by the signal model. Frozen tissue storage did not alter the signal components but influenced component amplitudes. D2O exchange was necessary to characterize the non‐aqueous signal components, but component amplitude mapping could be reliably performed also in the presence of H2O signals.Conclusions: The myelin mapping approach explored here produced reasonable and stable results for all samples. The extensive tissue and methodological investigations performed in this work form a basis for signal interpretation in future studies both ex vivo and in vivo.

3 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
EBEmily Louise Baadsvik
Emily Louise Baadsvik
MWMarkus Weiger
Markus Weiger
RFRomain Froidevaux
Romain Froidevaux
MRManuela Barbara Rösler
Manuela Barbara Rösler
DBDavid Otto Brunner
David Otto Brunner
KPKlaas Paul Pruessmann
Klaas Paul Pruessmann