We have applied a micro droplet generator (μDG) for sample introduction of single selenized yeast cells into a sector field ICP-MS, which was operated in a fast scanning mode with sampling rates of up to 10 kHz, to measure single cells time resolved with 100 μs integration time. Selenized yeast cells have been used as a model system for preliminary investigation. The single cells to be measured have been embedded into droplets and it will be shown that the time duration of a single cell event always is about 400 to 500 μs, and thus comparable to the time duration of a droplet without a cell. A fixed droplet generation rate of 50 Hz produced equidistant signals in time of each droplet event and was advantageous to separate contribution from background and blank from the analytical signal. Open vessel digestion and a multielement analysis were performed with washed yeast cells and absolute amounts per single cell were determined for Na (0.91 fg), Mg (9.4 fg), Fe (5.9 fg), Cu (0.54 fg), Zn (1.2 fg) and Se (72 fg). Signal intensities from single cells have been measured for the elements Cu, Zn and Se, and histograms were calculated for about 1000 cell events. The mean elemental sensitivities measured here range from 0.7 counts per ag (Se) to 10 counts per ag (Zn) with RSD's from 49% (Zn) to 69% (Se) for about 1000 cell events.
4 January 2013 in Journal of Analytical Atomic Spectrometry
A micro-droplet generator (μDG) sample introduction system was coupled to a sector field ICP-MS instrument to investigate the analytical figures of merit with respect to single cell analysis. The sector field instrument was operated for the first time in a fast scanning mode (E-scan) with the shortest time resolution of 100 μs to measure the single droplet time resolved and using the original detector in a pulse counting mode without modification of the existing electronics. For reduction of the droplet diameter a triple pulse mode of the droplet generator was applied and a droplet diameter down to 23 μm has been achieved for this investigation with a 100% transport efficiency of droplets. Signal duration times of single droplets of less than 500 μs have been measured. Overall detection efficiencies in the range of 10−3 counts per atom have been achieved and absolute limits of detection range between 120 ag for Fe and 1.1 ag for Mg as a mean value from 1000 droplet events.
6 June 2007 in Journal of Analytical Atomic Spectrometry
Se-containing proteins play an important role in human metabolic processes such as antioxidant action. However, speciation analysis of Se-containing proteins in biological samples is challenging because of their small amounts. In order to determine selenoprotein P (Sel-P) in human plasma, separation performance was compared between size exclusion chromatography and affinity chromatography. It was found that affinity chromatography showed better separation performance for Sel-P. Micro-affinity chromatography coupled with low flow ICP-MS was developed, which enabled separation analysis of Sel-P in sub-μl samples. Standard solution flow rate ranges for low sample consumption and total consumption nebulizers were investigated. Moreover, the stability analysis for each nebulizer with the change in composition of the mobile phase was investigated. Finally, using the developed micro-affinity chromatography coupled with the low flow ICP-MS, Sel-P and the other Se-containing proteins in sub-μl samples of human plasma were determined.
In order to elucidate Se metabolism in a living body, 82Se-enriched selenite was injected intravenously into mice fed Se-adequate and -deficient diets. We studied the time-dependent changes in the distribution of the labeled Se in organs, red blood cells, and plasma. The total Se was determined by flow-injection ICPMS, and Se speciation analysis was conducted by micro-affinity chromatography coupled with low-flow ICPMS. Total Se in almost all organs, including liver, showed the maximum at 1 h after injection. From speciation analysis, exogenous 82Se as Se-containing proteins other than selenoprotein P (Sel-P) (selenium containing albumin (SeAlb) and extra cellular glutathione peroxidase (eGPx)), peaked at 1 h and quickly decreased from 1 to 6 h after injection, whereas that as Sel-P, peaked at 6 h, and gradually decreased from 6 to 72 h after injection. We found that there were two pathways for the transfer of Se in mice; one was as SeAlb until 1 h after injection, and the other was as Sel-P from 6 to 72 h after injection.
23 April 2015 in Journal of Analytical Atomic Spectrometry
An optimal signal acquisition and processing method for use with intermittent small-sized sample introduction techniques, such as the micro-droplet injection system (M-DIS), was investigated.
7 May 2015 in Journal of Analytical Atomic Spectrometry
We evaluated the analytical performances of a new sample introduction system using a magnetic valve type dispenser, which can generate a large variety of droplet sizes for stable injection of cell suspension.