Jason Ken Adhinarta

Jason Ken Adhinarta

Auto-generated profile, based on publicly available information

Jason Ken Adhinarta

Boston College, Chestnut Hill, MA, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LJLiang Jin
Liang Jin
SGShixuan Gu
Shixuan Gu
DWDonglai Wei
Donglai Wei
JAJason Ken Adhinarta
Jason Ken Adhinarta
KKKaiming Kuang
Kaiming Kuang
MLming Li
ming Li
Automatic rib labeling and anatomical centerline extraction are common prerequisites for various clinical applications. Prior studies either use in-house datasets that are inaccessible to communities, or focus on rib segmentation that neglects the clinical significance of rib labeling. To address these issues, we extend our prior dataset ( RibSeg ) on the binary rib segmentation task to a comprehensive benchmark, named RibSeg v2 , with 660 CT scans (15,466 individual ribs in total) and annotations manually inspected by experts for rib labeling and anatomical centerline extraction. Based on the RibSeg v2 , we develop a pipeline including deep learning-based methods for rib labeling, and a skeletonization-based method for centerline extraction. To improve computational efficiency, we propose a sparse point cloud representation of CT scans and compare it with standard dense voxel grids. Moreover, we design and analyze evaluation metrics to address the key challenges of each task. Our dataset, code, and model are available online to facilitate open research at https://github.com/M3DV/RibSeg.

9 June 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
JWJia Wan
Jia Wan
WLWanhua Li
Wanhua Li
JAJason Ken Adhinarta
Jason Ken Adhinarta
ABAtmadeep Banerjee
Atmadeep Banerjee
ESEvelina Sjöstedt
Evelina Sjöstedt
DWDonglai Wei
Donglai Wei
While imaging techniques at macro and mesoscales have garnered substantial attention and resources, microscale Volume Electron Microscopy (vEM) imaging, capable of revealing intricate vascular details, has lacked the necessary benchmarking infrastructure. In this paper, we address a significant gap in this field of neuroimaging by introducing the first-in-class public benchmark, BvEM, designed specifically for cortical blood vessel segmentation in vEM images. Our BvEM benchmark is based on vEM image volumes from three mammals: adult mouse, macaque, and human. We standardized the resolution, addressed imaging variations, and meticulously annotated blood vessels through semi-automatic, manual, and quality control processes, ensuring high-quality 3D segmentation. Furthermore, we developed a zero-shot cortical blood vessel segmentation method named TriSAM, which leverages the powerful segmentation model SAM for 3D segmentation. To extend SAM from 2D to 3D volume segmentation, TriSAM employs a multi-seed tracking framework, leveraging the reliability of certain image planes for tracking while using others to identify potential turning points. This approach effectively achieves long-term 3D blood vessel segmentation without model training or fine-tuning. Experimental results show that TriSAM achieved superior performances on the BvEM benchmark across three species. Our dataset, code, and model are available online at https://jia-wan.github.io/bvem.

5 August 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
XHXiaomeng Han
Xiaomeng Han
XLXiaotang Lu
Xiaotang Lu
PLPeter H. Li
Peter H. Li
SWShuohong Wang
Shuohong Wang
RSRichard Schalek
Richard Schalek
JLJeff W. Lichtman
Jeff W. Lichtman
Mapping neuronal networks is a central focus in neuroscience. While volume electron microscopy (vEM) can reveal the fine structure of neuronal networks (connectomics), it does not provide molecular information to identify cell types or functions. We developed an approach that uses fluorescent single-chain variable fragments (scFvs) to perform multiplexed detergent-free immunolabeling and volumetric-correlated-light-and-electron-microscopy on the same sample. We generated eight fluorescent scFvs targeting brain markers. Six fluorescent probes were imaged in the cerebellum of a female mouse, using confocal microscopy with spectral unmixing, followed by vEM of the same sample. The results provide excellent ultrastructure superimposed with multiple fluorescence channels. Using this approach, we documented a poorly described cell type, two types of mossy fiber terminals, and the subcellular localization of one type of ion channel. Because scFvs can be derived from existing monoclonal antibodies, hundreds of such probes can be generated to enable molecular overlays for connectomic studies.

26 January 2026 in Nature
Verified
Journal Article
Open access
PDF file
LZLirong Zheng
Lirong Zheng
DSDongqing Shi
Dongqing Shi
YYYixiao Yan
Yixiao Yan
BZBingxin Zhou
Bingxin Zhou
JLJormay Lim
Jormay Lim
CLChangyang Linghu
Changyang Linghu
Gene expression is dynamically controlled by gene regulatory networks comprising multiple regulatory components to mediate cellular functions 1 . An ideal tool for analysing these processes would track multi-component dynamics with both spatiotemporal resolution and scalability within the same cells, a capability not yet achieved. Here we present CytoTape, a genetically encoded, physiologically compatible, modular protein tape recorder for multiplexed and spatiotemporally scalable recording of gene regulation dynamics continuously for up to 3 weeks, with single-cell, up to minutes-scale resolution. CytoTape uses a flexible, thread-like, elongating intracellular protein self-assembly engineered via computationally assisted rational design, built on our earlier XRI technology 2 . We demonstrate its utility across multiple mammalian cell types, achieving simultaneous recording of five transcription factor activities and gene transcriptional activities. CytoTape reveals that divergent transcriptional trajectories correlate with transcriptional history and signal integration, and that distinct immediate early genes (IEGs) exhibit complex temporal correlations within single cells. We further extended CytoTape into CytoTape-vivo for scalable, spatiotemporally resolved single-cell recording in the living brain, enabling simultaneous weeks-long recording of doxycycline-dependent and IEG promoter-dependent gene expression histories across up to 14,123 neurons spanning multiple brain regions per mouse. Together, the CytoTape toolkit establishes a versatile platform for scalable and multiplexed analysis of cell physiological processes in vitro and in vivo.

21 May 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
XHXiaomeng Han
Xiaomeng Han
XLXiaotang Lu
Xiaotang Lu
PLPeter H. Li
Peter H. Li
Shuohong WangShuohong Wang
Shuohong Wang
RSRichard Schalek
Richard Schalek
JLJeff W. Lichtman
Jeff W. Lichtman
Mapping neuronal networks that underlie behavior has become a central focus in neuroscience. While serial section electron microscopy (ssEM) can reveal the fine structure of neuronal networks (connectomics), it does not provide the molecular information that helps identify cell types or their functional properties. Volumetric correlated light and electron microscopy (vCLEM) combines ssEM and volumetric fluorescence microscopy to incorporate molecular labeling into ssEM datasets. We developed an approach that uses small fluorescent single-chain variable fragment (scFv) immuno-probes to perform multiplexed detergent-free immuno-labeling and ssEM on the same samples. We generated eight such fluorescent scFvs that targeted useful markers for brain studies (green fluorescent protein, glial fibrillary acidic protein, calbindin, parvalbumin, voltage-gated potassium channel subfamily A member 2, vesicular glutamate transporter 1, postsynaptic density protein 95, and neuropeptide Y). To test the vCLEM approach, six different fluorescent probes were imaged in a sample of the cortex of a cerebellar lobule (Crus 1), using confocal microscopy with spectral unmixing, followed by ssEM imaging of the same sample. The results show excellent ultrastructure with superimposition of the multiple fluorescence channels. Using this approach we could document a poorly described cell type in the cerebellum, two types of mossy fiber terminals, and the subcellular localization of one type of ion channel. Because scFvs can be derived from existing monoclonal antibodies, hundreds of such probes can be generated to enable molecular overlays for connectomic studies.

1 December 2025 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SGShixuan Leslie Gu
Shixuan Leslie Gu
JAJason Ken Adhinarta
Jason Ken Adhinarta
MBMikhail Bessmeltsev
Mikhail Bessmeltsev
JYJiancheng Yang
Jiancheng Yang
YZYongjie Jessica Zhang
Yongjie Jessica Zhang
DWDonglai Wei
Donglai Wei
Accurate segmentation of anatomical substructures within 3D curvilinear structures in medical imaging remains challenging due to their complex geometry and the scarcity of diverse, large-scale datasets for algorithm development and evaluation. In this paper, we use dendritic spine segmentation as a case study and address these challenges by introducing a novel Frenet-Serret Framebased Decomposition, which decomposes 3D curvilinear structures into a globally smooth continuous curve that captures the overall shape, and a cylindrical primitive that encodes local geometric properties. This approach leverages Frenet-Serret Frames and arc length parameterization to preserve essential geometric features while reducing representational complexity, facilitating data-efficient learning, improved segmentation accuracy, and generalization on 3D curvilinear structures. To rigorously evaluate our method, we introduce two datasets: CurviSeg, a synthetic dataset for 3D curvilinear structure segmentation that validates our method's key properties, and DenSpineEM, a benchmark for dendritic spine segmentation, which comprises 4,476 manually annotated spines from 70 dendrites across three public electron microscopy datasets, covering multiple brain regions and species. Our experiments on DenSpineEM demonstrate exceptional cross-region and cross-species generalization: models trained on the mouse somatosensory cortex subset achieve 94.43% Dice, maintaining strong performance in zero-shot segmentation on both mouse visual cortex (95.61% Dice) and human frontal lobe (86.63% Dice) subsets. Moreover, we test the generalizability of our method on the IntrA dataset, where it achieves 77.08% Dice (5.29% higher than prior arts) on intracranial aneurysm segmentation from entire artery models. These findings demonstrate the potential of our approach for accurately analyzing complex curvilinear structures across diverse medical imaging fields. Our dataset, code, and models are available at https://github.com/VCG/FFD4DenSpineEM to support future research.