Keson Beng Choon Tan

Keson Beng Choon Tan

Auto-generated profile, based on publicly available information

Keson Beng Choon Tan

Associate Professor, Department of Prosthodontics, Faculty of Dentistry, National University of Singapore, Singapore

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2001 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
JGJian-Ping Geng
Jian-Ping Geng
KTKeson B.C. Tan
Keson B.C. Tan
GLGui-Rong Liu
Gui-Rong Liu

1 July 2005 in Medical Care
Verified
Journal Article
Closed access
DKDavid Koh
David Koh
MLMeng Kin Lim
Meng Kin Lim
SCSin Eng Chia
Sin Eng Chia
SKSoo Meng Mmed Ko
Soo Meng Mmed Ko
FQFeng Mbbs Qian
Feng Mbbs Qian
CFCalvin Mmed Fones
Calvin Mmed Fones
Introduction: Healthcare workers (HCWs) were at the frontline during the battle against Severe Acute Respiratory Syndrome (SARS). Understanding their fears and anxieties may hold lessons for handling future outbreaks, including acts of bioterrorism. Method: We measured risk perception and impact on personal and work life of 15,025 HCWs from 9 major healthcare institutions during the SARS epidemic in Singapore using a self-administered questionnaire and Impact of Events Scale and analyzed the results with bivariate and multivariate statistics. Results: From 10,511 valid questionnaires (70% response), we found that although the majority (76%) perceived a great personal risk of falling ill with SARS, they (69.5%) also accepted the risk as part of their job. Clinical staff (doctors and nurses), staff in daily contact with SARS patients, and staff from SARS-affected institutions expressed significantly higher levels of anxiety. More than half reported increased work stress (56%) and work load (53%). Many experienced social stigmatization (49%) and ostracism by family members (31%), but most (77%) felt appreciated by society. Most felt that the personal protective measures implemented were effective (96%) and that the institutional policies and protocols were clear (93%) and timely (90%). Conclusion: During epidemics, healthcare institutions have a duty to protect HCWs and help them cope with their personal fears and the very stressful work situation. Singapore's experience shows that simple protective measures based on sound epidemiological principles, when implemented in a timely manner, go a long way to reassure HCWs.

1 October 2010 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Mirza Rustum BaigMirza Rustum Baig
Mirza Rustum Baig
KTKeson Beng-Choon Tan
Keson Beng-Choon Tan
JNJack I. Nicholls
Jack I. Nicholls

1 November 2002 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Adrian U Jin YapAdrian U Jin Yap
Adrian U Jin Yap
KTKeson B.C. Tan
Keson B.C. Tan
CPCert Prosthodont
Cert Prosthodont
ECEe Kiam Chua
Ee Kiam Chua
HTHee Hon Tan
Hee Hon Tan

1 March 2019 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
MTMing Tan
Ming Tan
SYSophia Yee
Sophia Yee
KWKeng Wong
Keng Wong
YTYing Tan
Ying Tan
KTKeson Tan
Keson Tan
Ming Yi Tan, BDS, MDS/Sophia Hui Xin Yee, BDS, MDS/Keng Mun Wong, BDS, MSD/Ying Han Tan, BDS, MSc/Keson Beng Choon Tan, BDS, MSD: Purpose: This study compared the three-dimensional (3D) accuracy of conventional impressions with digital impression systems (intraoral scanners and dental laboratory scanners) for two different interimplant distances in maxillary edentulous arches. Materials and Methods: Six impression systems comprising one conventional impression material(Impregum), two intraoral scanners (TRIOS and True Definition), and three dental laboratory scanners (Ceramill Map400, inEos X5, and D900) were evaluated on two completely edentulous maxillary arch master models (A and B) with six and eight implants, respectively. Centroid positions at the implant platform level were derived using either physical or virtual probe hits with a coordinate measuring machine. Comparison of centroid positions between master and test models (n = 5) defined linear distortions (dx, dy, dz), global linear distortions (dR), and 3D reference distance distortions between implants (ΔR). The two-dimensional (2D) angles between the central axis of each implant to the x- or y-axes were compared to derive absolute angular distortions (Absdθx, Absdθy). Results: Model A mean dR ranged from 8.7 ? 8.3 μm to 731.7 ? 62.3 μm. Model B mean dR ranged from 16.3 ? 9 μm to 620.2 ? 63.2 μm. Model A mean Absdθx ranged from 0.021 ? 0.205 degrees to ?2.349 ? 0.166 degrees, and mean Absdθy ranged from ?0.002 ? 0.160 degrees to ?0.932 ? 0.290 degrees. Model B mean Absdθx ranged from ?0.007 ? 0.076 degrees to ?0.688 ? 0.574 degrees, and mean Absdθy ranged from ?0.018 ? 0.048 degrees to ?1.052 ? 0.297 degrees. One-way analysis of variance (ANOVA) by Impression system revealed significant differences among test groups for dR and ΔR in both models, with True Definition exhibiting the poorest accuracy. Independent samples t tests for dR, between homologous implant location pairs in Model A versus B, revealed the presence of two to four significant pairings (out of seven possible) for the intraoral scanner systems, in which instances dR was larger in Model A by 110 to 150 μm. Conclusion: Reducing interimplant distance may decrease global linear distortions (dR) for intraoral scanner systems, but had no effect on Impregum and the dental laboratory scanner systems. Impregum consistently exhibited the best or second-best accuracy at all implant locations, while True Definition exhibited the poorest accuracy for all linear distortions in both Models A and B. Impression systems could not be consistently ranked for absolute angular distortions.

16 March 2004 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
JGJ. P. Geng
J. P. Geng
QMQ. S. Ma
Q. S. Ma
WXW. Xu
W. Xu
KTK. B. C. Tan
K. B. C. Tan
GLG.R. Liu
G.R. Liu