1 January 2020 in Clinical Biomechanics
Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 - hole Dynamic Hip Screw with a 2 - hole plate, a standard gamma nail with dynamic and static distal locking and a long gamma nail. The specimens were tested with cyclic axial loading, from 500 N increasing of 50 N increments in each cycle. Force at failure, overall stiffness, stiffness at the fracture site, location and mode of failure were recorded. The short gamma nails dislocated into varus under preload because the nail migrated laterally. The Dynamic Hip Screw was initially stable, but some specimens rotated around the lag screw. The gamma nail was rotationally stable. Both implants failed through femur fracture. The long gamma nailed failed by screw cut - out at forces lower than the ultimate force of the short gamma nail. This study shows that the gamma nail is unstable in a large medullary canal but offers better rotational stability of the proximal fragment. A modification of the nail design or the operative technique may be considered.
1 July 2017 in Computers & Structures
2 April 2019 in Textile Research Journal
The presented work deals with the thermal ageing evaluation for polyester-reinforced and polyvinyl chloride coated fabrics. The architectural fabric AF9032 was exposed to artificial thermal ageing by subjecting the material samples to temperature levels of 80℃ and 90℃ for up to 12 weeks. The mechanical properties of the aged fabric have been separately described by the identified linear piecewise model (with assumption of the elastic behavior) and by the Bodner–Partom model (with assumption of the viscoplastic behavior). The evolution of the obtained parameter values for various ageing temperatures and over ageing periods have been approximated by linear functions achieving a good convergence. The simplified methodology of Arrhenius has been incorporated for the extrapolation of functions obtained for 90℃ and consequently used for ageing analysis. For the fill direction, the lines describing evolution of the mechanical parameters over ageing time coincide fully with the ultimate tensile strength and elongation at break and are parallel for the Bodner–Partom model parameters ( ) when comparing results for 80° and 90℃. For the warp direction, the obtained lines concerning mechanical properties and Bodner–Partom parameters exhibit different tendencies (increasing or decreasing) for both temperatures. Thus, the ageing evaluation according to the Arrhenius law has been confirmed by the obtained results only for the fill direction.
8 May 2018 in Textile Research Journal
In this paper the coupled service (constructional tension) and environmental (sunlight, rainfalls, temperature variations) ageing influence on the polyester-reinforced polyvinyl chloride (PVC)-coated fabric VALMEX is studied. Two cases of the same fabric have been analyzed: one USED for 20 years on the real construction of the Forest Opera in Sopot (Poland), and one kept as a spare material (NOT USED). The following tests have been conducted: uniaxial tensile, biaxial tensile and long-term creep tests. The obtained results have been used for the parameter identification of the piecewise non-linear, Burgers and Bodner–Partom models. Next, the analysis of the influence of environmental conditions on the parameters of these models has been made. It has been concluded that some parameters are more and the others are less sensitive to the exposure to environmental and mechanical conditions. The change of material parameters for fill threads (due to larger deformation) is higher. The obtained results may be useful in the durability evaluation of the textile membranes reinforced with polyester threads and PVC coated. All the constitutive models with the identified parameters may be used for the numerical analysis of structures made of fabrics at the service beginning and after long-term usage.
17 January 2025 in Frontiers in Bioengineering and Biotechnology
Introduction: Most orthopedic implants for fracture fixation and joint replacement are commonly tested on artificial bones. Polyurethane foam is one of the most frequently used synthetic bone materials for mimicking human trabecular tissue. The study aimed to examine the compressive and tensile behavior of polyurethane foams mimicking trabecular tissue in artificial human femurs and assess their potential to replicate the osteoporotic type of human bone tissue.Materials and methods: Two types of SYNBONE femur models, one of normal density (model 2350) and one of lower density (model LD2350), and three types of Sawbones femur models (models 1130-21-8, 1130-21-3, and 1130-192) were investigated. Polyurethane foams were extracted as slices cut in the coronal plane from the femoral head. Cuboid samples were cut in three directions and uniaxial tested to identify compressive and tensile properties, including elastic modulus, Poisson’s ratio, yield limit, and ultimate strength.Results: The ANOVA test revealed that only SYNBONE LD2350 trabecular tissue exhibits anisotropy properties (p < 0.001). In most cases, the tensile properties were greater than compressive ones (t-test, p < 0.001).Conclusion: The obtained results are within the ranges suggested by other authors for mimicking osteoporotic human tissue. The presented data broadens the range of data on mechanical properties provided by the producers. These data can serve as a reference for research using composite femurs made of these particular polyurethane foams for conducting biomechanical studies and validating accompanying numerical simulations.
5 November 2021 in PLOS ONE
MTMarcin Zmuda Trzebiatowski
Marcin Zmuda Trzebiatowski
In the current research, 68 specimens of orbital superior and/or medial walls taken from 33 human cadavers (12 females, 21 males) were subjected to uniaxial tension untill fracture. The samples were cut in the coronal (38 specimens) and sagittal (30 specimens) planes of the orbital wall. Apparent density (ρapp), tensile Young’s modulus (E-modulus) and ultimate tensile strength (UTS) were identified. Innovative test protocols were used to minimize artifacts and analyze the obtained data: (1) grips dedicated to non-symmetrical samples clamping were applied for mechanical testing, (2) non-contact measuring system of video-extensometer was employed for displacement registration, (3) ink imprint technique coupled with CAD analysis was applied to precisely access the cross-sectional areas of tested samples. With regard to a pooled group, apparent density for the coronal and sagittal cut plane was equal 1.53 g/cm3 and 1.57 g/cm3, tensile Young’s modulus 2.36 GPa and 2.14 GPa, and ultimate tensile strength 12.66 MPa and 14.35 MPa, respectively. No significant statistical differences (p > 0.05) were found for all the analyzed parameters when comparing coronal and sagittal plane cut groups. These observations confirmed the hypothesis that direction of sample cut does not affect the mechanical response of the orbital wall tissue, thus suggesting that mechanical properties of orbital wall bone show isotropic character.