1 June 2016 in American Journal of Obstetrics and Gynecology
27 August 2022 in Journal of Perinatology
10 September 2025 in Science Translational Medicine
CWChristopher J. Winckler
+6
Endotracheal intubation is a critical medical procedure for protecting a patient’s airway. Current intubation technology requires extensive anatomical knowledge, training, technical skill, and a clear view of the glottic opening. However, all of these may be limited during emergency care for trauma and cardiac arrest outside the hospital, where first-pass failure is nearly 35%. To address this challenge, we designed a soft robotic device to autonomously guide a breathing tube into the trachea with the goal of allowing rapid, repeatable, and safe intubation without the need for extensive training, skill, anatomical knowledge, or a glottic view. During initial device testing with highly trained users in a mannequin and a cadaver, we found a 100% success rate and an average intubation duration of under 8 s. We then conducted a preliminary study comparing the device with video laryngoscopy, in which prehospital medical providers with 5 min of device training intubated cadavers. When using the device, users achieved an 87% first-pass success rate and a 96% overall success rate, requiring an average of 1.1 attempts and 21 s for successful intubation, significantly ( P = 0.008) faster than with video laryngoscopy. When using video laryngoscopy, the users achieved a 63% first-pass success rate and a 92% overall success rate, requiring an average of 1.6 attempts and 44 s for successful intubation. This preliminary study offers directions for future clinical studies, the next step in testing a device that could address the critical needs of emergency airway management and help democratize intubation.
12 October 2024 in BJA Open
Maintaining an appropriate depth of anaesthesia is important for avoiding adverse effects from undermedication or overmedication during surgery. Electroencephalography (EEG) has become increasingly used to achieve this balance. Investigating the predictive power of intracranial EEG (iEEG) and scalp EEG for different levels of sedation could increase the utility of EEG monitoring. Simultaneous iEEG, scalp EEG, and Observer's Assessment of Alertness/Sedation (OAA/S) scores were recorded during emergence from anaesthesia in seven patients undergoing placement of intracranial electrodes for medically refractory epilepsy. A deep learning model was constructed to predict an OAA/S score of 0–2 vs 3–5 using iEEG, scalp EEG, and their combination. An additional five patients with only scalp EEG data were used for independent validation. Models were evaluated using the area under the receiver-operating characteristic curve (AUC). Combining scalp EEG and iEEG yielded significantly better prediction (AUC=0.795, P<0.001) compared with iEEG only (AUC=0.750, P=0.02) or scalp EEG only (AUC=0.764, P<0.001). The validation scalp EEG only data resulted in an AUC of 0.844. Combining the two modalities appeared to capture spatiotemporal advantages from both modalities. The combination of iEEG and scalp EEG better predicted sedation level than either modality alone. The scalp EEG only model achieved a similar AUC to the combined model and maintained its performance in additional patients, suggesting that scalp EEG models are likely sufficient for real-time monitoring. Deep learning approaches using multiple leads to capture a wider area of brain activity may help augment existing EEG monitors for prediction of sedation.