8 June 2022 in Ageing Research Reviews
1 August 2013 in Experimental Eye Research
1 January 2012 in Investigative Ophthalmology & Visual Science
Purpose. To determine the protection factor (PF) for glutaredoxin-1 (Grx1) with regard to UVR-induced cataract by comparison of in vivo ultraviolet radiation (UVR) lens toxicity between double knockout Grx1−/− and Grx1+/+ mice. Methods. Twenty Grx1+/+ mice and 20 Grx1−/− mice were unilaterally exposed in vivo to UVR for 15 minutes. Groups of four animals each received 0.0, 2.1, 2.9, 3.6, and 4.1 kJ/m2 UVR-300 nm. At 48 hours after UVR exposure, light-scattering in the exposed and contralateral nonexposed lenses was measured quantitatively. Macroscopic lens changes were documented with dark-field illumination photography. Results. UVR-300 nm induced subcapsular and cortical cataract in Grx1−/− and Grx1+/+ mice. In both Grx1−/− and Grx1+/+, the light-scattering intensified with increased in vivo exposure doses of UVR-300 nm. The intensity of forward light-scattering was higher in the lenses of Grx1−/− mice than in the lenses of Grx1+/+ mice. The threshold dose for in vivo UVR-300 nm–induced cataract, expressed as MTD2.3:16, was 3.8 in the Grx1+/+ group and 3.0 in the Grx1−/− group, resulting in a PF of 1.3. Conclusions. The PF is an objective relative measure of protective properties. The Grx1 gene is associated with an in vivo PF of 1.3. This result signifies that the presence of the gene allows a 1.3 times longer in vivo exposure to UVR, at equivalent irradiance, than the absence of the gene before early-onset, UVR-induced cataract occurs. This finding indicates the important role of the Grx1 gene in the oxidation defense system of the lens.
25 March 2014 in Acta Ophthalmologica
Purpose: The aim of the study is to investigate and visualize the ultrastructure of cataract morphology and repair, after in vivo exposure to double threshold dose UVR‐B in the C57BL/6 mouse lens.Methods: Twenty‐six‐week‐old C57BL/6 mice received in vivo double threshold dose (6.4 kJ/m2) UVR‐B for 15 min. The radiation output of the UVR‐source had λMAX at 302.6 nm. After a latency period of 1, 2, 4 and 8 days following UVR‐B exposure, the induced cataract was visualized with electron microscopy techniques. Induced, cataract was quantified as forward lens light scattering. Damage to the lens epithelium and the anterior cortex was investigated with light microscopy in toluidine blue‐stained semi‐thin sections, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and dark field illumination photography.Results: UVR‐B‐exposed lenses developed anterior subcapsular and/or cortical and nuclear cataract after 1 day. Lens light scattering peaked 2 days after exposure. Lens epithelial cell damage was seen in TEM as apoptotic cells, apoptotic bodies, nuclear chromatin condensation, and swollen and disrupted anterior cortex fibres throughout the sections of the whole anterior lens surface. These morphologic changes were also visualized with SEM. Within 8 days, anterior subcapsular cataract was repaired towards the anterior sutures.Conclusion: UVR‐B exposure of double cataract threshold dose induces a subtotal loss of epithelial cells across the whole anterior surface of the lens. This damage to the epithelium is repaired by epithelial cell movement from the equator towards the lens sutures, thus in retrograde direction to regular epithelial cell differentiation.
1 August 2022 in Journal of Cataract & Refractive Surgery
A technique for achieving an optimal flange size with 5-0 polypropylene and 6-0 polypropylene used for flanged intrascleral intraocular lens fixation is described. Flange size in polypropylene sutures is dependent on heating length and independent of forceps grip during heating. It was identified that heating of 1 mm created the optimal flange size for a 5-0 polypropylene suture when used for a 27-gauge needle scleral tunnel and for a 6-0 polypropylene suture when used for a 30-gauge needle scleral tunnel. Alternatively, 2 mm heating of a 6-0 polypropylene suture fits well for a 27-gauge needle tunnel. Even gentle forceps grip caused flattening of the polypropylene sutures but did not influence shaping and sizing of the flange.