Suguru Sato

Suguru Sato

Auto-generated profile, based on publicly available information

Suguru Sato

Graduate School of Engineering, The University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TTTakuma Takagi
Takuma Takagi
NTNaoto Tomita
Naoto Tomita
SSSuguru Sato
Suguru Sato
MYMichitaka Yamamoto
Michitaka Yamamoto
STSeiichi Takamatsu
Seiichi Takamatsu
TIToshihiro Itoh
Toshihiro Itoh
We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics—where stress remains nearly constant during deformation—between the electromyography (EMG) electrode and clothing to suppress motion artifacts in EMG measurement. Wearable EMG devices are receiving attention for monitoring muscle weakening due to aging. However, daily EMG measurement has been challenging due to motion artifacts caused by changes in the contact pressure between the bioelectrode and the skin. Therefore, this study aims to measure EMG signals in daily movement environments by controlling the contact pressure using polyurethane foam between the bioelectrode on the clothing and the skin. Through mechanical calculations and finite element method simulations of the polyurethane foam’s effect, we clarified that the characteristics of the polyurethane foam significantly influence contact pressure control and that the contact pressure is adjustable through the polyurethane foam thickness. The optimization of the design successfully controlled the contact pressure between the bioelectrode and skin from 1.0 kPa to 2.0 kPa, effectively suppressing the motion artifact in EMG measurement.

11 November 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SSSuguru Sato
Suguru Sato
JNJunya Nakagawa
Junya Nakagawa
MYMichitaka Yamamoto
Michitaka Yamamoto
STSeiichi Takamatsu
Seiichi Takamatsu
TKTakeshi Kobayashi
Takeshi Kobayashi
TIToshihiro Itoh
Toshihiro Itoh
We have developed a car seat with a pressure sensor array embedded under polyurethane (PU) foam to monitor the posture and driving behavior of the drivers. Each pressure sensor consists of a 5-μm-thick piezoresistive micro-electro-mechanical systems (MEMS) strain gauge wired on a 3D printed parallel-plate cantilever. A cover is attached on top of the cantilever pressure sensor to concentrate the pressure applied through the PU foam, and it is surrounded by a plastic frame of the same height to prevent geometric nonlinear pressure sensor characteristics. To monitor drivers, the proposed 4 × 4 pressure sensor array is embedded under the PU foam of a car seat. The pressure sensor has a sensitivity range of 0–20 kPa and a determination coefficient of the sensor’s regression line of 0.99, which exhibits high linearity. Our evaluation using the prototype sensor array and a driving simulator demonstrated that driver posture changes and braking behavior could be detected. The sensor array is expected to be applied to smart car seats for automated vehicles in the future.

12 November 2025 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
NTNaoto Tomita
Naoto Tomita
SSSuguru Sato
Suguru Sato
TNTakumi Noda
Takumi Noda
MYMichitaka Yamamoto
Michitaka Yamamoto
TATakashi Azuma
Takashi Azuma
STSeiichi Takamatsu
Seiichi Takamatsu
Wearable ultrasound probes that enable non-invasive, continuous monitoring of internal body tissues have attracted increasing attention. Among various approaches, fabric-based probes are particularly promising due to their inherent flexibility, durability, and potential for seamless integration into garments. However, implementing high-density ultrasound arrays on fabric remains technically challenging, primarily due to the difficulty in forming reduced-pitch electrical wiring, which degrades imaging quality. In this study, we propose a novel fabrication approach using xurography, a wiring formation technique, to create tightly pitched electrical wiring on fabric. Furthermore, choosing glass fabric as the substrate—owing to its high mechanical and thermal resilience—enhanced the durability of the wiring; the fabricated wiring maintained stable resistance over 1,000 bending cycles. Using this method, we developed a 16-element flexible ultrasound probe with a 600 μm element pitch on a glass fabric. In imaging experiments with tissue-mimicking phantoms, the probe clearly visualized string targets and simulated blood vessels. The signal-to-noise ration of string targets improved by up to 6.3 dB, and the contrast-to-noise ratio for the vessel improved by 5.3 dB compared to previous design. These results demonstrate that the proposed approach overcomes the limitations of previous fabric-based probes and has potential for wearable healthcare applications.