Franz Siegfried Englbrecht

Franz Siegfried Englbrecht

Auto-generated profile, based on publicly available information

Franz Siegfried Englbrecht

Department of Medical Physics, Ludwig-Maximilians University, Am Coulombwall 1, Garching, Munich, Bavaria, 85748, GERMANY

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2017 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
YGYing Gao
Ying Gao
JBJianhui Bin
Jianhui Bin
DHDaniel Haffa
Daniel Haffa
CKChristian Kreuzer
Christian Kreuzer
JHJens Hartmann
Jens Hartmann
JSJörg Schreiber
Jörg Schreiber
We report on a target system supporting automated positioning of nano-targets with a precision resolution of $4~\unicode[STIX]{x03BC}\text{m}$ in three dimensions. It relies on a confocal distance sensor and a microscope. The system has been commissioned to position nanometer targets with 1 Hz repetition rate. Integrating our prototype into the table-top ATLAS 300 TW-laser system at the Laboratory for Extreme Photonics in Garching, we demonstrate the operation of a 0.5 Hz laser-driven proton source with a shot-to-shot variation of the maximum energy about 27% for a level of confidence of 0.95. The reason of laser shooting experiments operated at 0.5 Hz rather than 1 Hz is because the synchronization between the nano-foil target positioning system and the laser trigger needs to improve.

20 April 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
STSebastian Trinkl
Sebastian Trinkl
VMVladimir Mares
Vladimir Mares
FEFranz Siegfried Englbrecht
Franz Siegfried Englbrecht
JWJan Jakob Wilkens
Jan Jakob Wilkens
MWMarek Wielunski
Marek Wielunski
MHMartin Hillbrand
Martin Hillbrand

1 May 2021 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Closed access
FEFranz S. Englbrecht
Franz S. Englbrecht
STSebastian Trinkl
Sebastian Trinkl
VMVladimír Mares
Vladimír Mares
WRWerner Rühm
Werner Rühm
MWMarek Wielunski
Marek Wielunski
KPKatia Parodi
Katia Parodi

1 June 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
TRThomas F. Rösch
Thomas F. Rösch
ZSZoltán Szabó
Zoltán Szabó
DHDaniel Haffa
Daniel Haffa
JBJianhui Bin
Jianhui Bin
SBSzilvia Brunner
Szilvia Brunner
JSJörg Schreiber
Jörg Schreiber
The development from single shot basic laser plasma interaction research toward experiments in which repetition rated laser-driven ion sources can be applied requires technological improvements. For example, in the case of radio-biological experiments, irradiation duration and reproducible controlled conditions are important for performing studies with a large number of samples. We present important technological advancements of recent years at the ATLAS 300 laser in Garching near Munich since our last radiation biology experiment. Improvements range from target positioning over proton transport and diagnostics to specimen handling. Exemplarily, we show the current capabilities by performing an application oriented experiment employing the zebrafish embryo model as a living vertebrate organism for laser-driven proton irradiation. The size, intensity, and energy of the laser-driven proton bunches resulted in evaluable partial body changes in the small (<1 mm) embryos, confirming the feasibility of the experimental system. The outcomes of this first study show both the appropriateness of the current capabilities and the required improvements of our laser-driven proton source for in vivo biological experiments, in particular the need for accurate, spatially resolved single bunch dosimetry and image guidance.

1 May 2019 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Closed access
MHMartin Hillbrand
Martin Hillbrand
GLGuillaume Landry
Guillaume Landry
SESandy Ebert
Sandy Ebert
GDGeorge Dedes
George Dedes
EPEleftherios P. Pappas
Eleftherios P. Pappas
KPKatia Parodi
Katia Parodi

7 January 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MWM Würl
M Würl
FEF Englbrecht
F Englbrecht
KPK Parodi
K Parodi
MHM Hillbrand
M Hillbrand
Due to the low-dose envelope of scanned proton beams, the dose output depends on the size of the irradiated field or volume. While this field size dependence has already been extensively investigated by measurements and Monte Carlo (MC) simulations for single pencil beams or monoenergetic fields, reports on the relevance of this effect for analytical dose calculation models are limited. Previous studies on this topic only exist for specific beamline designs. However, the amount of large-angle scattered primary and long-range secondary particles and thus the relevance of the low-dose envelope can considerably be influenced by the particular design of the treatment nozzle. In this work, we therefore addressed the field size dependence of the dose output at the commercially available ProBeam® beamline, which is being built in several facilities worldwide. We compared treatment planning dose calculations with ionization chamber (IC) measurements and MC simulations, using an experimentally validated FLUKA MC model of the scanning beamline. To this aim, monoenergetic square fields of three energies, as well as spherical target volumes were studied, including the investigation on the influence of the lateral spot spacing on the field size dependence. For the spherical target volumes, MC as well as analytical dose calculation were found in excellent agreement with the measurements in the center of the spread-out Bragg peak. In the plateau region, the treatment planning system (TPS) tended to overestimate the dose compared to MC calculations and IC measurements by up to almost 5% for the smallest investigated sphere and for small monoenergetic square fields. Narrower spot spacing slightly enhanced the field size dependence of the dose output. The deviations in the plateau dose were found to go in the clinically safe direction, i.e. the actual deposited dose outside the target was found to be lower than predicted by the TPS. Thus, the moderate overestimation of dose to normal tissue by the TPS is likely to result in no severe consequences in clinical cases, even for the most critical cases of small target volumes.