11 June 2025 in The Astrophysical Journal
(C(On Behalf of the COSI Collaboration)
(On Behalf of the COSI Collaboration)
+6
The Compton Spectrometer and Imager (COSI) is a Compton telescope designed to survey the 0.2–5 MeV sky, consisting of a compact array of cross-strip germanium detectors. As part of its development, in 2016 COSI had a successful 46 day flight on board NASA’s Super Pressure Balloon platform. This was a precursor to the COSI Small Explorer (COSI-SMEX) satellite mission that will launch in 2027 into an equatorial low Earth (530 km) orbit. The observation of MeV gamma rays is dominated by background radiation, especially due to the activation of the detector materials induced by cosmic-ray interactions. Thus, background simulation and identification are crucial for the data analysis. Because the COSI-SMEX detectors will be similar to the ones used for the balloon flight, the balloon measurements provide an important tool for testing and cross-checking our background simulations for the upcoming space mission. In this work we perform Monte Carlo simulations of the background emission from the 2016 COSI balloon flight. Including a phenomenological shape correction, we obtain an agreement with the data at the 10%–20% level for energies between 0.1 and 1.6 MeV, and we successfully reproduce most of the activation lines induced by cosmic-ray interactions.
13 May 2025 in Astronomy & Astrophysics
IMI. Martinez-Castellanos
+20
We present a modified Richardson-Lucy (RL) algorithm tailored for image reconstruction in MeV gamma-ray observations, focusing on its application to the upcoming Compton Spectrometer and Imager (COSI) mission. Our method addresses key challenges in MeV gamma-ray astronomy by incorporating Bayesian priors for sparseness and smoothness while optimizing background components simultaneously. We introduce a novel sparsity term suitable for Poisson-sampled data in addition to a smoothness prior, allowing for flexible reconstruction of both point sources and extended emission. The performance of the algorithm is evaluated using simulated three-month COSI observations of gamma-ray lines of 44Ti (1.157 MeV), 26Al (1.809 MeV), and positron annihilation (0.511 MeV), respectively, representing various spatial features. Our results demonstrate significant improvements over conventional RL methods, particularly in suppressing artificial structures in point source reconstructions and retaining diffuse spatial structures. This work represents an important step toward establishing a robust data analysis for studying nucleosynthesis, positron annihilation, and other high-energy phenomena in our Galaxy.
1 October 2024 in The Astrophysical Journal
FCfor the COSI Collaboration
for the COSI Collaboration
+7
The atmospheric response for MeV γ rays (∼0.1–10 MeV) can be characterized in terms of two observed components. The first component is due to photons that reach the detector without scattering. The second component is due to photons that reach the detector after scattering one or more times. While the former can be determined in a straightforward manner, the latter is much more complex to quantify, as it requires tracking the transport of all source photons that are incident on Earth’s atmosphere. The scattered component can cause a significant energy-dependent distortion in the measured spectrum, which is important to account for when making balloon-borne observations. In this work, we simulate the full response for γ-ray transport in the atmosphere. We find that the scattered component becomes increasingly more significant toward lower energies, and at 0.1 MeV, it may increase the measured flux by as much as a factor of ∼2–4, depending on the photon index and off-axis angle of the source. This is particularly important for diffuse sources, whereas the effect from scattering can be significantly reduced for point sources observed with an imaging telescope.
28 January 2026 in The Astrophysical Journal
The Compton Spectrometer and Imager (COSI) is a Compton telescope designed to survey the 0.2–5 MeV sky, consisting of a compact array of cross-strip germanium detectors. It is planned to be launched in 2027 into an equatorial low-Earth (530 km) orbit with a prime mission duration of 2 yr. The observation of MeV gamma rays is dominated by background. Thus, background simulation and identification are crucial for predicting the sensitivities of instruments. In this work we perform Monte Carlo simulations of the background for the first 3 months in orbit, and we extrapolate the results to 2 yr in orbit in order to determine the buildup of the activation due to long-lived isotopes. The simulations account for the known background components and include time-dependent rate variations due to the geomagnetic cutoff and South Atlantic Anomaly (SAA) passages. In addition, they include detailed modeling of the delayed activation due to short- and long-lived isotopes. We determine the rates of events induced by the background that are reconstructed as Compton events in the simulated COSI data. We find that the extragalactic background photons dominate at low energies (<660 keV), while delayed activation from cosmic-ray primaries (proton/alpha) and albedo photons dominate at higher energies. As part of this work, a comparison at low latitude (∣ b ∣ ≤ 1°) between recent measurement of the SAA and the AP9/AE9 model has been made, showing an overestimation of the flux by a factor ∼9 by the model. The systematic uncertainties associated with these components are quantified.
20 January 2026 in The Astrophysical Journal
The Compton Spectrometer and Imager (COSI) is a NASA satellite mission under development designed to survey the entire sky at 0.2–5 MeV with a wide-field gamma-ray telescope. Its main instrument is a germanium detector array surrounded on the sides and bottom by bismuth germanium oxide scintillator active shields (the “Anticoincidence Subsystem” (ACS)) to reduce and monitor background and for detecting transients. COSI will have an onboard trigger algorithm to detect gamma-ray bursts (GRBs) in the ACS and send data to the ground for further analysis. In this paper, we present three localization methods that we evaluated for the localization of short GRBs (sGRBs) using the ACS light curves. The first method is the χ 2 fit already used by the Fermi Gamma-ray Burst Monitor, which calculates the best fit between look-up tables and the GRB data. The second method is a maximum likelihood estimation fit implemented in bc-tools for the BurstCube mission that performs a fit between the instrument response function and the GRB data. The last method is based on deep learning techniques and consists of a neural network developed for the COSI mission and trained to perform a regression of the sGRB position, taking as input the count rates of each ACS panel. The localization errors obtained by analyzing simulated sGRBs with the three methods are consistent. Despite the theoretical similarity between the approaches, their consistency in results is noteworthy, as they differ substantially in their implementations and optimization processes. The bc-tools obtain the best localization accuracy.
2 February 2026 in IEEE Transactions on Nuclear Science
The Compton Spectrometer and Imager is an upcoming NASA space telescope in the MeV range. COSI’s primary science goals include precisely mapping positron annihilation and nuclear line emissions in the Milky Way galaxy through Compton imaging. This relies on our ability to maintain COSI’s spectral performance over its mission lifetime. Changes in the detectors’ gain characteristics over time will result in inaccurate measurement of astrophysical gamma-ray energies. Moreover, observations from past MeV telescopes and proton-beam experiments have shown that radiation damage in space causes photopeak shifts and spectral line broadening. These necessitate a plan for regular, in-orbit spectral calibration. In this study, we demonstrate a method to monitor and recalibrate the COSI detectors using background line emissions produced by the space radiation environment. We employ Monte Carlo simulations of particle background and show that strong background lines arise from nuclear excitation of COSI’s detectors (germanium) and cryostat (aluminum) materials. These span COSI’s entire bandwidth for single-site interactions and can be used to monitor the effects of radiation damage and gain shifts every 12 hours at the full instrument level and every 16 days at the individual detector level. Methods developed by Pike et al. [1, 2] to correct the effects of hole trapping and gain characteristics can then be applied to recover the original spectral performance. These results inform COSI’s telemetry requirements for calibration and housekeeping data, and rule out the need for an onboard radioactive calibration source, which would have increased the complexity of the spacecraft.