Eugene Christo V R

Eugene Christo V R

Auto-generated profile, based on publicly available information

Eugene Christo V R

B CUBE – Center for Molecular Bioengineering TUD Dresden University of Technology Dresden Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2025 in Nano Letters
Verified
Journal Article
Open access
EREugene Christo V R
Eugene Christo V R
EKEsther Charlotte Sophia Kloth
Esther Charlotte Sophia Kloth
FNFilippo Nisini
Filippo Nisini
CRCordula Reuther
Cordula Reuther
SDStefan Diez
Stefan Diez
Microtubule gliding assays provide a unique mechanism for molecular detection in which binding of analytes to the microtubule lattice reduces the microtubule gliding speed. The reduction in the gliding speed correlates with the density of the bound analytes, enabling its quantification. Although promising, this technique is still in the proof-of-concept stage. Improving the sensitivity and limit of detection of the assay could make the technique comparable to that of advanced molecular detection methods. This study demonstrates that reducing the ionic strength of the buffer increases the sensitivity of the assay by enhancing the interactions between kinesin and microtubules. When using a low ionic strength buffer (BRB10) compared with a standard buffer (BRB80), we observed a more pronounced reduction in microtubule gliding speed in the presence of analytes, improving the detection limit. Therefore, this approach offers a simple and scalable way to improve the sensitivity of motor-based detection assays.

24 August 2026 in Small
Verified
Journal Article
Open access
PDF file
EREugene Christo V R
Eugene Christo V R
CMChristoph R. Meinecke
Christoph R. Meinecke
BNBert Nitzsche
Bert Nitzsche
RLRoman Lyttleton
Roman Lyttleton
CRCordula Reuther
Cordula Reuther
SDStefan Diez
Stefan Diez
Network‐based biocomputing (NBC) presents an energy‐efficient, parallel computing approach for solving nondeterministic polynomial time (NP) complete problems by leveraging motor‐driven cytoskeletal filaments that explore all possible solutions through nanofabricated networks in a massively parallel fashion. However, guiding errors at pass junctions, where filaments deviate from their intended path, currently limit the scalability of NBC systems. In this study, we addressed this critical challenge by fabricating sub‐200 nm channel geometries using modified electron‐beam‐lithography and reactive‐ion‐etching protocols to physically constrain the trajectories of kinesin‐driven microtubules and enhance path fidelity. Investigating junction designs with varying channel widths, we demonstrate that reducing channel width significantly lowers junction error rates. Practically error‐free junction performance was achieved by scaling down the entire network geometry by a factor of two. These optimized junctions were incorporated into NBC networks that successfully solved 24‐ and 25‐set instances of the Exact Cover problem, representing solution spaces of approximately 16 and 33 million, respectively. This work establishes a new benchmark in NBC performance and represents a computational scale far beyond what has been achieved in prior demonstrations.

16 September 2025 in bioRxiv
Verified
Preprint
Open access
EREugene Christo V R
Eugene Christo V R
CMChristoph R. Meinecke
Christoph R. Meinecke
BNBert Nitzsche
Bert Nitzsche
RLRoman Lyttleton
Roman Lyttleton
CRCordula Reuther
Cordula Reuther
SDStefan Diez
Stefan Diez
Network-based biocomputing (NBC) presents an energy-efficient, parallel computing approach for solving nondeterministic polynomial time (NP) complete problems by leveraging motor-driven cytoskeletal filaments that explore all possible solutions through nanofabricated networks in a massively parallel fashion. However, guiding errors at pass junctions, where filaments deviate from their intended path, currently limit the scalability of NBC systems. In this study, we addressed this critical challenge by fabricating sub-200 nm channel geometries using modified electron-beam-lithography and reactive-ion-etching protocols to physically constrain the trajectories of kinesin-driven microtubules and enhance path fidelity. Investigating junction designs with varying channel widths, we demonstrate that reducing channel width significantly lowers junction error rates. Practically error-free junction performance was achieved by scaling down the entire network geometry by a factor of two. These optimized junctions were incorporated into NBC networks that successfully solved 24- and 25-set instances of the Exact Cover problem, representing solution spaces of approximately 16 million and 33 million, respectively. This work establishes a new benchmark in NBC performance and represents a computational scale far beyond what has been achieved in prior demonstrations.