Sara Hashemi

Sara Hashemi

Auto-generated profile, based on publicly available information

Sara Hashemi

Dental Students' Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
MDMahmood Dashti
Mahmood Dashti
JLJimmy Londono
Jimmy Londono
SGShohreh Ghasemi
Shohreh Ghasemi
STShivasadat Tabatabaei
Shivasadat Tabatabaei
SHSara Hashemi
Sara Hashemi
Zohaib KhurshidZohaib Khurshid
Zohaib Khurshid
With the growing importance of implant brand detection in clinical practice, the accuracy of machine learning algorithms in implant brand detection has become a subject of research interest. Recent studies have shown promising results for the use of machine learning in implant brand detection. However, despite these promising findings, a comprehensive evaluation of the accuracy of machine learning in implant brand detection is needed. The purpose of this systematic review and meta-analysis was to assess the accuracy, sensitivity, and specificity of deep learning algorithms in implant brand detection using 2-dimensional images such as from periapical or panoramic radiographs. Electronic searches were conducted in PubMed, Embase, Scopus, Scopus Secondary, and Web of Science databases. Studies that met the inclusion criteria were assessed for quality using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Meta-analyses were performed using the random-effects model to estimate the pooled performance measures and the 95% confidence intervals (CIs) using STATA v.17. Thirteen studies were selected for the systematic review, and 3 were used in the meta-analysis. The meta-analysis of the studies found that the overall accuracy of CNN algorithms in detecting dental implants in radiographic images was 95.63%, with a sensitivity of 94.55% and a specificity of 97.91%. The highest reported accuracy was 99.08% for CNN Multitask ResNet152 algorithm, and sensitivity and specificity were 100.00% and 98.70% respectively for the deep CNN (Neuro-T version 2.0.1) algorithm with the Straumann SLActive BLT implant brand. All studies had a low risk of bias. The highest accuracy and sensitivity were reported in studies using CNN Multitask ResNet152 and deep CNN (Neuro-T version 2.0.1) algorithms.

14 August 2023 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
JLJimmy Londono
Jimmy Londono
SGShohreh Ghasemi
Shohreh Ghasemi
NMNegar Moghaddasi
Negar Moghaddasi
HBHoma Baninajarian
Homa Baninajarian
Amir FahimipourAmir Fahimipour
Amir Fahimipour
MDMahmood Dashti
Mahmood Dashti
Objectives: The aim of this article is to establish a comprehensive nationwide prevalence of malocclusion traits on the sagittal, vertical, and transverse planes of space in the Turkish population.Material and Methods: A systematic search of PubMed, Scopus, and Web of Science was supplemented by manual searches of Google Scholar and the reference lists of included studies. Original Turkish health studies of any age were included. Strengthening the Reporting of Observational Studies in Epidemiology assessed study quality and bias (STROBE). Sagittal, vertical, and transverse malocclusion features were retrieved and gathered.Results: Eleven studies were selected from 434 titles. Two studies showed a high risk of bias, eight low and one moderate. Thirteen thousand two hundred seventy‐one individuals were investigated from early childhood to late adulthood. Most studies were sampled from universities and dental (nonorthodontic) clinics. The pooled malocclusion prevalence was 56% for Class I (95% confidence interval (CI): 44−68%), 31% for Class II (CI: 6–42%), and 11% for Class III (CI: 21–37%). The other common types of malocclusions were crowding (41%, CI: 18–65%), overjet (34%, CI: 21–50%), negative overjet (13%, CI: 7–20%), and crossbite (11%, CI: 7–15%). Additionally, there was no significant difference in Class I (relative risk [RR] = 1.00, [0.96–1.05]), Class II ([RR] = 0.97, [0.92–1.03]), and Class III ([RR] = 1.08, [0.96–1.225]) malocclusion by gender.Conclusions: This study showed Class I malocclusion has a high prevalence among the Turkish population followed by Class II and Class III malocclusions. In addition, crowding and overjet were the most prevalent malocclusions among Turkish individuals. There were no significant differences in the prevalence of malocclusions between males and females.

7 May 2023 in Journal of Evidence-Based Dental Practice
Verified
Journal Article
Closed access
NANarjes Amrollahi
Narjes Amrollahi
SHSara Hashemi
Sara Hashemi
ZHZahra Heidari
Zahra Heidari

7 January 2023 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
AFAmir hossein Fathi
Amir hossein Fathi
SHSara Hashemi
Sara Hashemi
STShivasadat Tabatabaei
Shivasadat Tabatabaei
RMRamin Mosharraf
Ramin Mosharraf
RARamin Atash
Ramin Atash

14 April 2023 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SHSara Hashemi
Sara Hashemi
STShivasadat Tabatabaei
Shivasadat Tabatabaei
AFAmir hossein Fathi
Amir hossein Fathi
SASeyedeh Mohadeseh Asadinejad
Seyedeh Mohadeseh Asadinejad
RARamin Atash
Ramin Atash
This umbrella review aims to evaluate systematic/meta-analysis studies containing clinical evidence on tooth grafts as bone substitutes in the oral and maxillofacial regions. Using language restrictions and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, an electronic database search of PubMed, MEDLINE, Embase, Cochrane library, and Google Scholar was conducted, featuring published studies up until August 2022. All systematic/meta-analysis review articles relating to tooth graft materials were matched against the inclusion criteria. Two qualified researchers independently assessed the studies' inclusion or exclusion criteria and risk of bias, and a third investigator assisted in resolving ambiguities. A total of 81 systematic/meta-analysis studies, comprising 21 animal-controlled trials, 23 randomized controlled human trials, 23 prospective studies, and 14 retrospective studies, were selected for this study. A small risk of bias was observed in systematic studies/meta-analyses. In addition, the clinical evidence from the analysis of these studies revealed a low incidence of side effects. According to the current review, two systematic reviews indicated that autogenous bone grafting of prepared teeth might be as effective as other bone grafting materials. Four studies also mentioned autologous grafts as potential alternatives to autologous grafts, autogenous demineralized dentin (ADDM), engineered grafts, root blocks, and dental matrix. On the other hand, three systematic studies stated that more long-term research is needed to confirm their findings. Finally, given the importance of standardization and homogeneity of studies for clinical cases, it is advised to be used cautiously due to the risks of transplant rejection.

17 August 2023 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SHSara Hashemi
Sara Hashemi
STShivasadat Tabatabaei
Shivasadat Tabatabaei
KBkimia baghaei
kimia baghaei
AFAmir hossein Fathi
Amir hossein Fathi
RARamin Atash
Ramin Atash
Long-term clinical outcomes of short dental implants (≤6 mm) supporting single crowns or short fixed partial dentures have been reported differently in different studies and need more clarification. This systematic study evaluated the rate of bone loss (BL), the durability of implants equal to or shorter than 6 mm supporting single crowns or short fixed partial dentures, and prosthetic-related side effects during 5 years of follow-up. Five databases (PubMed, MEDLINE, Scopus, Google Scholar, and Cochrane) were electronically and manually searched for longitudinal studies with a follow-up period of 5 years or more until January 2023. The study question was, “Does the implant equal to or shorter than 6 mm affect BL and survival rate of the implant-supported prosthesis after 5 years of follow-up?”. From 752 identified articles, nine studies were selected for further evaluation. After 5 years of follow-up, most studies had more than 90% survival rate and the maximum BL was 0.54 mm. Still, in internal and external connections, these changes were not substantial. For example, screw loosening was the most common problem with implanted prostheses. Implants of 6 mm or shorter are a suitable treatment option in atrophic ridges with good durability and fewer side effects during a follow-up period of more than 5 years.