Adria Marcos-Pastor

Adria Marcos-Pastor

Auto-generated profile, based on publicly available information

Adria Marcos-Pastor

Department of Electronic, Electrical and Automatic Engineering, Universitat Rovira i Virgili, Tarragona, Spain

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AMAdria Marcos-Pastor
Adria Marcos-Pastor
Enric Vidal-IdiarteEnric Vidal-Idiarte
Enric Vidal-Idiarte
ACAngel Cid-Pastor
Angel Cid-Pastor
LMLuis Martinez-Salamero
Luis Martinez-Salamero
This study describes a digitally controlled power factor correction (PFC) system based on two interleaved boost converters operating with pulsewidth modulation (PWM). Both converters are independently controlled by an inner control loop based on a discrete-time sliding-mode (SM) approach that imposes loss-free resistor (LFR) behavior on each cell. The switching surface implements an average current-mode controller so that the power factor (PF) is high. The SM-based digital controller is designed to operate at a constant switching frequency so that the interleaving technique, which is recommended for ac-dc power conversion systems higher than 1 kW, can be readily applied. An outer loop regulates the output voltage by means of a discrete-time proportional-integral (PI) compensator directly obtained from a discrete-time small-signal model of the ideal sliding dynamics. The control law proposed has been validated using numerical simulations and experimental results in a 2-kW prototype.

1 July 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AMAdria Marcos-Pastor
Adria Marcos-Pastor
Enric Vidal-IdiarteEnric Vidal-Idiarte
Enric Vidal-Idiarte
ACAngel Cid-Pastor
Angel Cid-Pastor
LMLuis Martinez-Salamero
Luis Martinez-Salamero
This letter presents the calculation of the minimum dc-link capacitance in power factor correction single-phase systems employing hysteretic current-mode control for low total harmonic distortion. The proposed design can be applied to the cascade connection of converters in which the source converter can be modeled as a loss-free resistor and the load converter can be characterized as a constant power load. The value of the minimum capacitance is obtained as a function of voltage and frequency of the mains, maximum power transferred to the load converter, and desired dc-link voltage. The resulting capacitance is ten times smaller than the one obtained by the conventional design. The theoretical predictions are verified by means of simulations and experiments.