Xiaodan Cui

Xiaodan Cui

Auto-generated profile, based on publicly available information

Xiaodan Cui

NARI Group Corporation,State Grid Electric Power Research Institute,Nanjing,China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Wangwang XuWangwang Xu
Wangwang Xu
ZXZhiqiang Xie
Zhiqiang Xie
XCXiaodan Cui
Xiaodan Cui
Kangning ZhaoKangning Zhao
Kangning Zhao
LZLei Zhang
Lei Zhang
YWYing Wang
Ying Wang

1 August 2018 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
XCXiaodan Cui
Xiaodan Cui
BZBoliang Zhang
Boliang Zhang
Congyuan ZengCongyuan Zeng
Congyuan Zeng
HWHao Wen
Hao Wen
SGShengmin Guo
Shengmin Guo

1 June 2018 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
XCXiaodan Cui
Xiaodan Cui
BZBoliang Zhang
Boliang Zhang
CZCongyuan Zeng
Congyuan Zeng
HWHao Wen
Hao Wen
HYHong Yao
Hong Yao
SGShengmin Guo
Shengmin Guo

1 April 2023
Verified
Conference Paper
Closed access
JWJialong Wu
Jialong Wu
XCXiaodan Cui
Xiaodan Cui
JFJiaqi Feng
Jiaqi Feng
YWYanpin Wang
Yanpin Wang
KDKui Deng
Kui Deng
BCBoyuan Cao
Boyuan Cao
Large-scale grid-connected power supply based on inverters brings severe challenges to the stability and security control of power system. Due to the simulation resources and calculation efficiency, it's necessary to equivalent the multi-inverter power supply in the new energy field when conducting the system stability and security simulation analysis. In this paper, for the scenario where multiple inverters of the same type are connected to weak grid, the open-loop transfer function and output impedance of the inverter grid-connected current are derived based on frequency analysis, and the stability judgment based on the impedance model in weak grid is obtained. Furthermore, the transfer functions of the inverter single equivalent and multiplication equivalent solutions are derived. The stability differences and key influencing factors are analyzed between the two equivalent solutions and the actual parallel multi-inverter system. Finally, the results of the theoretical analysis are verified by simulation based on an example. Through theoretical and simulation studies, the differences in the principles, effects of different equivalent schemes and the applicable conditions are clarified, and guidance is provided for reasonable selection of inverter equivalent solutions and simulation analysis.