Alexander Scott Ditter

Alexander Scott Ditter

Auto-generated profile, based on publicly available information

Alexander Scott Ditter

Chemical Sciences Division, Lawrence Berkeley National Laboratory 2 , Berkeley, California 94720

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
EJEvan P. Jahrman
Evan P. Jahrman
WHWilliam M. Holden
William M. Holden
ADAlexander S. Ditter
Alexander S. Ditter
DMDevon R. Mortensen
Devon R. Mortensen
GSGerald T. Seidler
Gerald T. Seidler
MSMartin C Stennett
Martin C Stennett
X-ray absorption fine structure (XAFS) and x-ray emission spectroscopy (XES) are advanced x-ray spectroscopies that impact a wide range of disciplines. However, unlike the majority of other spectroscopic methods, XAFS and XES are accompanied by an unusual access model, wherein the dominant use of the technique is for premier research studies at world-class facilities, i.e., synchrotron x-ray light sources. In this paper, we report the design and performance of an improved XAFS and XES spectrometer based on the general conceptual design of Seidler et al. [Rev. Sci. Instrum. 85, 113906 (2014)]. New developments include reduced mechanical degrees of freedom, much-increased flux, and a wider Bragg angle range to enable extended x-ray absorption fine structure (EXAFS) measurement and analysis for the first time with this type of modern laboratory XAFS configuration. This instrument enables a new class of routine applications that are incompatible with the mission and access model of the synchrotron light sources. To illustrate this, we provide numerous examples of x-ray absorption near edge structure (XANES), EXAFS, and XES results for a variety of problems and energy ranges. Highlights include XAFS and XES measurements of battery electrode materials, EXAFS of Ni with full modeling of results to validate monochromator performance, valence-to-core XES for 3d transition metal compounds, and uranium XANES and XES for different oxidation states. Taken en masse, these results further support the growing perspective that modern laboratory-based XAFS and XES have the potential to develop a new branch of analytical chemistry.

23 October 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ADAlexander S. Ditter
Alexander S. Ditter
EJEvan P. Jahrman
Evan P. Jahrman
LBLiam R. Bradshaw
Liam R. Bradshaw
XXXiaojing Xia
Xiaojing Xia
PPPeter J Pauzauskie
Peter J Pauzauskie
GSGerald T. Seidler
Gerald T. Seidler

1 January 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EJEvan P. Jahrman
Evan P. Jahrman
WHWilliam M. Holden
William M. Holden
ADAlexander S. Ditter
Alexander S. Ditter
SKStosh A. Kozimor
Stosh A. Kozimor
SKScott L. Kihara
Scott L. Kihara
GSGerald T. Seidler
Gerald T. Seidler
We demonstrate that vacuum forming of 10-cm diameter silicon wafers of various crystallographic orientations under an x-ray permeable, flexible window can easily generate spherically bent crystal analyzers and toroidally bent crystal analyzers with ∼1-eV energy resolution and a 1-m major radius of curvature. In applications at synchrotron light sources, x-ray free electron lasers, and laboratory spectrometers, these characteristics are generally sufficient for many x-ray absorption fine structure (XAFS), x-ray emission spectroscopy (XES), and resonant inelastic x-ray scattering applications in the chemical sciences. Unlike existing optics manufacturing methods using epoxy or anodic bonding, vacuum forming without adhesive is temporary in the sense that the bent wafer can be removed when vacuum is released and exchanged for a different orientation wafer. Therefore, the combination of an x-ray compatible vacuum-forming chamber, a library of thin wafers, and a small number of forms having different secondary curvatures can give extreme flexibility in spectrometer energy range. As proof of this method, we determine the energy resolution and reflectivity for several such vacuum-formed bent crystal analyzers in laboratory-based XAFS and XES studies using a conventional x-ray tube. For completeness, we also show x-ray images collected on the detector plane to characterize the resulting focal spots and optical aberrations.

1 January 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ADAlexander Scott Ditter
Alexander Scott Ditter
DSDanil E. Smiles
Danil E. Smiles
DLDaniel Lussier
Daniel Lussier
AAAlison B. Altman
Alison B. Altman
MBMukesh Bachhav
Mukesh Bachhav
DSDavid K. Shuh
David K. Shuh
Soft X-ray spectromicroscopy at the O K-edge, U N 4,5-edges and Ce M 4,5-edges has been performed on focused ion beam sections of spent nuclear fuel for the first time, yielding chemical information on the sub-micrometer scale. To analyze these data, a modification to non-negative matrix factorization (NMF) was developed, in which the data are no longer required to be non-negative, but the non-negativity of the spectral components and fit coefficients is largely preserved. The modified NMF method was utilized at the O K-edge to distinguish between two components, one present in the bulk of the sample similar to UO2 and one present at the interface of the sample which is a hyperstoichiometric UO2+x species. The species maps are consistent with a model of a thin layer of UO2+x over the entire sample, which is likely explained by oxidation after focused ion beam (FIB) sectioning. In addition to the uranium oxide bulk of the sample, Ce measurements were also performed to investigate the oxidation state of that fission product, which is the subject of considerable interest. Analysis of the Ce spectra shows that Ce is in a predominantly trivalent state, with a possible contribution from tetravalent Ce. Atom probe analysis was performed to provide confirmation of the presence and localization of Ce in the spent fuel.

20 February 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ADAlexander S. Ditter
Alexander S. Ditter
WHWilliam M. Holden
William M. Holden
SCSamantha K. Cary
Samantha K. Cary
Veronika MockoVeronika Mocko
Veronika Mocko
MLMatthew J. Latimer
Matthew J. Latimer
GSGerald T. Seidler
Gerald T. Seidler

16 May 2022 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
ADAlex S. Ditter
Alex S. Ditter
JPJoseph I. Pacold
Joseph I. Pacold
ZDZurong Dai
Zurong Dai
MDM. Lee Davisson
M. Lee Davisson
DVDavid Vine
David Vine
DSDavid K. Shuh
David K. Shuh
The oxidation of uranium dioxide is a complicated process, depending on factors including humidity, temperature, and microstructure. To further determine the characteristics of this process, UO2 particles were allowed to age and agglomerate under 98% relative humidity at room temperature for 378 days. A focused ion beam (FIB) section of this agglomeration was then measured at the O K-edge, U N5-edge, and C K-edge using the scanning transmission x-ray microscope (STXM) at the Advanced Light Source. O K-edge and U N5-edge x-ray absorption measurements allowed for the elemental and chemical species mapping of the agglomerates and indicated the formation of schoepite at the submicrometer scale in specific locations. Non-negative matrix factorization was employed to elucidate the main components at the O K-edge, which were uranyl (schoepite) formed primarily at the interface of the sample with controlled atmosphere, a UO2-like bulk component present in the majority of the sample, and an oxygen species present at the surface of the FIB section, which is likely adsorbed water. STXM spectromicroscopy measurements at the U N5-edge measurements also confirmed the location of oxidized uranium. This analysis is a valuable insight into the formation of schoepite on UO2 and shows the sensitivity to and utility of STXM spectromicroscopy for uranium speciation.