We evaluated the value of BioFire® FilmArray® pneumonia panel in establishing a microbiological diagnosis of pneumonia. We evaluated opportunities for antimicrobial optimization from its use. We included adult patients with pneumonia between May 2019 and January 2020. The pneumonia panel was used on high-quality sputum specimens, and the results were prospectively compared with sputum cultures and other tests performed according to standard of care. Seventy patients were included, sixty-nine of whom completed a 5-day antimicrobial course for pneumonia, and 14.3% died during hospitalization. There was a trend of higher rate of microbiological diagnosis among the patients with culture submitted before antimicrobial administration (9/15 vs. 20/55; p = 0.09). The panel increased the microbiological diagnosis from 29/70 to 59/70 (p < 0.001) patients. The per isolate analysis revealed an increase in the isolation of Haemophilus influenzae (p = 0.002) and Streptococcus pneumoniae (p = 0.05). On review of empiric antimicrobials, there was potential for antimicrobial optimization in 56/70 patients, including 9 bacteria among 9 patients, which were not covered by empiric treatment and another 70 antimicrobials in 49 patients that could have been stopped. Incorporation of the pneumonia panel in the diagnostic work-up of pneumonia substantially increased the rate of microbiological diagnosis and revealed abundant opportunities for antimicrobial optimization.
Sepsis presents a major burden to the emergency department (ED). Because empiric inappropriate antimicrobial therapy (IAAT) is associated with increased mortality, rapid molecular assays may decrease IAAT and improve outcomes. We evaluated the cost-effectiveness of molecular testing as an adjunct to blood cultures in patients with severe sepsis or septic shock evaluated in the ED. We developed a decision analysis model with primary outcome the incremental cost-effectiveness ratio expressed in terms of deaths averted. Costs were dependent on the assay price and the patients’ length of stay (LOS). Three base-case scenarios regarding the difference in LOS between patients receiving appropriate (AAT) and IAAT were described. Sensitivity analyses regarding the assay cost and sensitivity, and its ability to guide changes from IAAT to AAT were performed. Under baseline assumptions, molecular testing was cost-saving when the LOS differed by 4 days between patients receiving IAAT and AAT (ICER -$7,302/death averted). Our results remained robust in sensitivity analyses for assay sensitivity≥52%, panel efficiency≥39%, and assay cost≤$270. In the extreme case that the LOS of patients receiving AAT and IAAT was the same, the ICER remained≤$20,000/death averted for every studied sensitivity (i.e. 0.5–0.95), panel efficiency≥34%, and assay cost≤$313. For 2 days difference in LOS, the bundle approach was dominant when the assay cost was≤$135 and the panel efficiency was≥77%. The incorporation of molecular tests in the management of sepsis in the ED has the potential to improve outcomes and be cost-effective for a wide range of clinical scenarios.
Background: SARS-CoV-2 infection continues to cause significant morbidity and mortality worldwide. Preliminary data on SARS-CoV-2 infection suggests that some immunocompromised hosts experience worse outcomes. We performed a retrospective matched cohort study to characterize outcomes in HIV-positive patients with SARS-CoV-2 infection. Methods: Leveraging data collected from electronic medical records for all patients hospitalized at NYU Langone Health with COVID-19 between March 2, 2020 and April 23, 2020, we matched 21 HIV-positive patients to 42 non-HIV patients using a greedy nearest neighbor algorithm. Admission characteristics, laboratory results, and hospital outcomes were recorded and compared between the two groups. Results: While there was a trend toward increased rates of ICU admission, mechanical ventilation, and mortality in HIV-positive patients, these differences were not statistically significant. Rates for these outcomes in our cohort are similar to those previously published for all patients hospitalized with COVID-19. HIV-positive patients had significantly higher admission and peak CRP values. Other inflammatory markers did not differ significantly between groups, though HIV-positive patients tended to have higher peak values during their clinical course. Three HIV-positive patients had superimposed bacterial pneumonia with positive sputum cultures, and all three patients expired during hospitalization. There was no difference in frequency of thrombotic events or myocardial infarction between these groups. Conclusion: This study provides evidence that HIV coinfection does not significantly impact presentation, hospital course, or outcomes of patients infected with SARS-CoV-2, when compared to matched non-HIV patients. A larger study is required to determine if the trends we observed apply to all HIV-positive patients.
The Infectious Diseases Society of America has identified the use of SARS-CoV-2 genomic load for prognostication purposes as a key research question. We designed a retrospective cohort study that included adult patients with COVID-19 pneumonia who had at least 2 positive nasopharyngeal tests at least 24 hours apart to study the correlation between the change in the genomic load of SARS-CoV-2, as reflected by the Cycle threshold (Ct) value of the RT-PCR, with change in clinical status. The Sequential Organ Failure Assessment (SOFA) score was used as a surrogate for patients’ clinical status. Among 457 patients with COVID-19 pneumonia between 3/31/2020-4/10/2020, we identified 42 patients who met the inclusion criteria. The median initial SOFA score was 2 (IQR 2–3). 20 out of 42 patients had a lower SOFA score on their subsequent tests. We identified a statistically significant inverse correlation between the change in SOFA score and change in the Ct value with a decrease in SOFA score by 0.05 (SE 0.02; p<0.05) for an increase in Ct values by 1. This correlation was independent of the duration of symptoms. Our findings suggest that an increasing Ct value in sequential tests may be of prognostic value for patients diagnosed with COVID-19 pneumonia.
1 August 2019 in Diagnostic Microbiology and Infectious Disease