Daniel DeBord

Daniel DeBord

Auto-generated profile, based on publicly available information

Daniel DeBord

MOBILion Systems, Inc. 4 Hillman Drive, Suite 130, Chadds Ford, PA 19317, United States

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Analytica Chimica Acta
Verified
Journal Article
Closed access
KMKelly L. Wormwood Moser
Kelly L. Wormwood Moser
GAGregory Van Aken
Gregory Van Aken
DDDaniel DeBord
Daniel DeBord
NHNathan Galen Hatcher
Nathan Galen Hatcher
LMLaura Maxon
Laura Maxon
KEKim Ekroos
Kim Ekroos

13 September 2023 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
KKKomal Kedia
Komal Kedia
RHRachel Harris
Rachel Harris
KEKim Ekroos
Kim Ekroos
KMKelly W Moser
Kelly W Moser
DDDaniel DeBord
Daniel DeBord
KBKevin Bateman
Kevin Bateman

19 October 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
DDDaniel DeBord
Daniel DeBord
LRLeonard C. Rorrer
Leonard C. Rorrer
LDLiulin Deng
Liulin Deng
FSFrederick G. Strathmann
Frederick G. Strathmann
In today’s fast-evolving landscape of omics research, tandem mass spectrometry has become a cornerstone for uncovering the complexities of biological systems. Yet, despite its essential role, the technology remains bound by the inherent limitations of quadrupole filters, which throw away up to 99% of the useful ion signal and caps the speed at which fragmentation data can be generated. These deficiencies often force compromises in data depth and accuracy, hindering breakthroughs that tie genomics, proteomics, and metabolomics together. A new technology is poised to break through these performance barriers, unlocking unprecedented capabilities in precision, sensitivity and throughput. This step-change in how mass spectrometry fragmentation analysis is performed will reshape the future of scientific discovery, pushing the boundaries of what’s possible. The solution is high resolution ion mobility (HRIM), which offers a means to quickly and efficiently isolate ions prior to fragmentation and detection by a high resolution mass spectrometer (HRMS) while also resolving challenging isomeric and isobaric compounds that lead to chimeric MS/MS spectra. HRIM isolates ions in time as a result of a high speed separation rather than acting as a filter that discards ion signal like the pervasive quadrupole mass analyzer, allowing higher sensitivity analysis to be achieved. Also, since HRIM eliminates the need to hop or sweep electronics control parameters, as is the case with a quadrupole, fragmentation spectral generation can occur at a much faster rate, upwards of 500 Hz. This whitepaper describes an IM/MS methodology first contemplated over twenty years ago and today being positioned as the fastest method for high resolution fragmentation analysis. Revisiting this concept using the latest generation ion mobility technology based on structures for lossless ion manipulation (SLIM), which is the only HRIM technology that delivers similar resolution and range of analysis as a quadrupole, realizes the full potential of this approach to deliver benefits in both speed and sensitivity for high performance MS/MS measurements. This new way of achieving ion fragmentation in complex samples is set to revolutionize the mass spectrometry space, starting in the growing field of proteomics where all researchers are seeking faster methods to achieve more comprehensive proteomic coverage. Due to the advantages of HRIM physics, we predict this will set the bar for high throughput -omics within the coming years and will eventually be as ubiquitous as the quadrupole is today.

5 December 2025 in Proteomics
Verified
Journal Article
Open access
IUIsabel R. Uribe
Isabel R. Uribe
LDLiulin Deng
Liulin Deng
LRLeonard Rorrer
Leonard Rorrer
LRLauren Royer
Lauren Royer
MFMiriam Fico
Miriam Fico
DDDaniel DeBord
Daniel DeBord
To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta‐analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole‐based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ∼5 Th quadrupole isolation window, while providing the additional benefit of generating non‐chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM‐QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10× increase in precursor isolation specificity as compared to either of the techniques independently.

22 May 2025
Verified
Preprint
Open access
IUIsabel Uribe
Isabel Uribe
LDLiulin Deng
Liulin Deng
LILeonard Rorrer Iii
Leonard Rorrer Iii
LRLauren Royer
Lauren Royer
MFMiriam Fico
Miriam Fico
DDDaniel DeBord
Daniel DeBord
To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta-analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole-based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ~5 Th quadrupole isolation window, while providing the additional benefit of generating non-chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM-QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10x increase in precursor isolation specificity as compared to either of the techniques independently.

22 June 2026 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
LRLeonard C. Rorrer
Leonard C. Rorrer
LDLiulin Deng
Liulin Deng
LRLauren Royer
Lauren Royer
IUIsabel Uribe
Isabel Uribe
BOBen Orsburn
Ben Orsburn
DDDaniel DeBord
Daniel DeBord
Here we present a novel data independent acquisition (DIA) mass spectrometry (MS) operating mode termed parallel accumulation-mobility aligned fragmentation (PAMAF) that offers enhanced speed and sensitivity of ion fragmentation analysis for discovery workflows such as bottom-up proteomics. This mode of operation leverages high-resolution ion mobility (HRIM) separation capabilities of the structures for lossless ion manipulation (SLIM) technology to achieve HRIM-based precursor isolation in place of traditional quadrupole filtering approaches. PAMAF mode increases the number of features that can be identified per MS1/MS2 acquisition cycle by employing mobility-based time alignment to associate fragment ions with their corresponding precursor ions. By using a high-speed, lossless separation technique for precursor isolation instead of the comparatively slow and wasteful quadrupole filtering, ion losses are avoided while simultaneously increasing the rate at which precursor ions are sequentially fragmented and detected. Additionally, by accumulating ions while the previous packet of ions is being analyzed, the PAMAF mode achieves ∼100% ion utilization efficiency. Benchmarking results of LC-PAMAF-MS analysis of a whole cell protein digest showed ∼6x more protein group identifications compared to a standard data-dependent acquisition (DDA) analysis without HRIM on the same QTOF instrument, and to >100x improvement for low-load workflows. Quantitative evaluations demonstrated that PAMAF mode could quantify low abundance peptides, including those undetectable by DDA. Additionally, since precursor isolation in PAMAF mode is size-based rather than m/z-based, coeluting isobars and isomers can be resolved prior to fragmentation, eliminating chimeric spectra that compromise identification accuracy. We also explored the benefits of combining HRIM and quadrupole isolation to achieve improved specificity termed DIA-PAMAF mode, which enabled the detection of over 8,000 protein groups from a HeLa digest analysis. PAMAF mode brings a powerful new technique to the field of proteomics with the potential to improve the sensitivity and selectivity of mass spectrometry-based proteomics.