Paul O. Bolcos

Paul O. Bolcos

Auto-generated profile, based on publicly available information

Paul O. Bolcos

Department of Applied Physics University of Eastern Finland Kuopio Finland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PBPaul O. Bolcos
Paul O. Bolcos
Mika MononenMika Mononen
Mika Mononen
AMAli Mohammadi
Ali Mohammadi
MEMohammadhossein Ebrahimi
Mohammadhossein Ebrahimi
MTMatthew S. Tanaka
Matthew S. Tanaka
RKRami K. Korhonen
Rami K. Korhonen
Use of knee joint finite element models for diagnostic purposes is challenging due to their complexity. Therefore, simpler models are needed for studies where a high number of patients need to be analyzed, without compromising the results of the model. In this study, more complex, kinetic (forces and moments) and simpler, kinetic-kinematic (forces and angles) driven finite element models were compared during the stance phase of gait. Patella and tendons were included in the most complex model, while they were absent in the simplest model. The greatest difference between the most complex and simplest models was observed in the internal-external rotation and axial joint reaction force, while all other rotations, translations and joint reaction forces were similar to one another. In terms of cartilage stresses and strains, the simpler models behaved similarly with the more complex models in the lateral joint compartment, while minor differences were observed in the medial compartment at the beginning of the stance phase. We suggest that it is feasible to use kinetic-kinematic driven knee joint models with a simpler geometry in studies with a large cohort size, particularly when analyzing cartilage responses and failures related to potential overloads.

20 July 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
GOGustavo A. Orozco
Gustavo A. Orozco
PBPaul Bolcos
Paul Bolcos
AMAli Mohammadi
Ali Mohammadi
MTMatthew S. Tanaka
Matthew S. Tanaka
Mingrui YangMingrui Yang
Mingrui Yang
RKRami K. Korhonen
Rami K. Korhonen
The purpose of this proof‐of‐concept study was to develop three‐dimensional patient‐specific mechanobiological knee joint models to simulate alterations in the fixed charged density (FCD) around cartilage lesions during the stance phase of the walking gait. Two patients with anterior cruciate ligament (ACL) reconstructed knees were imaged at 1 and 3 years after surgery. The magnetic resonance imaging (MRI) data were used for segmenting the knee geometries, including the cartilage lesions. Based on these geometries, finite element (FE) models were developed. The gait of the patients was obtained using a motion capture system. Musculoskeletal modeling was utilized to calculate knee joint contact and lower extremity muscle forces for the FE models. Finally, a cartilage adaptation algorithm was implemented in both FE models. In the algorithm, it was assumed that excessive maximum shear and deviatoric strains (calculated as the combination of principal strains), and fluid velocity, are responsible for the FCD loss. Changes in the longitudinal T1ρ and T2 relaxation times were postulated to be related to changes in the cartilage composition and were compared with the numerical predictions. In patient 1 model, both the excessive fluid velocity and strain caused the FCD loss primarily near the cartilage lesion. T1ρ and T2 relaxation times increased during the follow‐up in the same location. In contrast, in patient 2 model, only the excessive fluid velocity led to a slight FCD loss near the lesion, where MRI parameters did not show evidence of alterations. Significance: This novel proof‐of‐concept study suggests mechanisms through which a local FCD loss might occur near cartilage lesions. In order to obtain statistical evidence for these findings, the method should be investigated with a larger cohort of subjects.

1 October 2020 in Clinical Biomechanics
Verified
Journal Article
Open access
PBPaul O. Bolcos
Paul O. Bolcos
Mika MononenMika Mononen
Mika Mononen
MTMatthew S. Tanaka
Matthew S. Tanaka
MYMingrui Yang
Mingrui Yang
JSJuha-Sampo Suomalainen
Juha-Sampo Suomalainen
RKRami K. Korhonen
Rami K. Korhonen
Finite element modelling can be used to evaluate altered loading conditions and failure locations in knee joint tissues. One limitation of this modelling approach has been experimental comparison. The aims of this proof-of-concept study were: 1) identify areas susceptible to osteoarthritis progression in anterior cruciate ligament reconstructed patients using finite element modelling; 2) compare the identified areas against changes in T2 and T1ρ values between 1-year and 3-year follow-up timepoints. Two patient-specific finite element models of knee joints with anterior cruciate ligament reconstruction were created. The knee geometry was based on clinical magnetic resonance imaging and joint loading was obtained via motion capture. We evaluated biomechanical parameters linked with cartilage degeneration and compared the identified risk areas against T2 and T1ρ maps. The risk areas identified by the finite element models matched the follow-up magnetic resonance imaging findings. For Patient 1, excessive values of maximum principal stresses and shear strains were observed in the posterior side of the lateral tibial and femoral cartilage. For Patient 2, high values of maximum principal stresses and shear strains of cartilage were observed in the posterior side of the medial joint compartment. For both patients, increased T2 and T1ρ values between the follow-up times were observed in the same areas. Finite element models with patient-specific geometries and motions and relatively simple material models of tissues were able to identify areas susceptible to post-traumatic knee osteoarthritis. We suggest that the methodology presented here may be applied in large cohort studies.

24 November 2021 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
PBPaul O. Bolcos
Paul O. Bolcos
Mika MononenMika Mononen
Mika Mononen
KRKoren E. Roach
Koren E. Roach
MTMatthew S. Tanaka
Matthew S. Tanaka
JSJuha‐Sampo Suomalainen
Juha‐Sampo Suomalainen
RKRami K Korhonen
Rami K Korhonen

21 September 2015
Verified
Conference Paper
Open access
SWStefanus Wirdatmadja
Stefanus Wirdatmadja
DMDmitri Moltchanov
Dmitri Moltchanov
PBPaul Bolcos
Paul Bolcos
JVJari Väliaho
Jari Väliaho
JKJoose Kreutzer
Joose Kreutzer
YKYevgeni Kourcheyavy
Yevgeni Kourcheyavy
We develop a microfluidic communication system prototype and conduct experiments to show the feasibility of data transmission. We apply using on/off keying and communication by silence modulation schemes for signal transmission. Their performance is evaluated by using data obtained experimentally. The data rate of these modulation schemes is computed as well. We identify the noise sources in microfluidic channels as setup related. The experiments reveal that communication by silence is significantly better than on/off keying. Our results show that both modulation schemes are feasible for signal transmission. Even though CtS outperforms OOK in terms of achievable data rate, from a practical point of view CtS is much harder to control, since there are more parameters to be controlled at the same time.