Dennis M. J. van de Sande

Dennis M. J. van de Sande

Auto-generated profile, based on publicly available information

Dennis M. J. van de Sande

Department of Biomedical Engineering Eindhoven University of Technology Eindhoven The Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DSDennis M. J. van de Sande
Dennis M. J. van de Sande
JMJulian P. Merkofer
Julian P. Merkofer
SASina Amirrajab
Sina Amirrajab
MVMitko Veta
Mitko Veta
RSRuud J. G. van Sloun
Ruud J. G. van Sloun
MBMarcel Breeuwer
Marcel Breeuwer
This literature review presents a comprehensive overview of machine learning (ML) applications in proton MR spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state‐of‐the‐art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the MR field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.

27 April 2025 in NMR in Biomedicine
Verified
Journal Article
Open access
JMJulian P. Merkofer
Julian P. Merkofer
DSDennis M. J. van de Sande
Dennis M. J. van de Sande
SASina Amirrajab
Sina Amirrajab
KNKyung Min Nam
Kyung Min Nam
RSRuud J. G. van Sloun
Ruud J. G. van Sloun
ABAlex A Bhogal
Alex A Bhogal
Accurate quantification of metabolites in magnetic resonance spectroscopy (MRS) is challenged by low signal‐to‐noise ratio (SNR), overlapping metabolites, and various artifacts. Particularly, unknown and unparameterized baseline effects obscure the quantification of low‐concentration metabolites, limiting MRS reliability. This paper introduces wavelet analysis‐based neural decomposition (WAND), a novel data‐driven method designed to decompose MRS signals into their constituent components: metabolite‐specific signals, baseline, and artifacts. WAND takes advantage of the enhanced separability of these components within the wavelet domain. The method employs a neural network, specifically a U‐Net architecture, trained to predict masks for wavelet coefficients obtained through the continuous wavelet transform. These masks effectively isolate desired signal components in the wavelet domain, which are then inverse‐transformed to obtain separated signals. Notably, an artifact mask is created by inverting the sum of all known signal masks, enabling WAND to capture and remove even unpredictable artifacts. The effectiveness of WAND in achieving accurate decomposition is demonstrated through numerical evaluations using simulated spectra. Furthermore, WAND's artifact removal capabilities significantly enhance the quantification accuracy of linear combination model fitting. The method's robustness is further validated using data from the 2016 MRS Fitting Challenge and in vivo experiments.

16 October 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DSD. M. J. van de Sande
D. M. J. van de Sande
AGA. T. Gudmundson
A. T. Gudmundson
SMS. Murali‐Manohar
S. Murali‐Manohar
CDC. W. Davies‐Jenkins
C. W. Davies‐Jenkins
DSD. Simicic
D. Simicic
RER. A. E. Edden
R. A. E. Edden
Purpose: Simulated data is increasingly valued by researchers for validating MRS processing and analysis algorithms. However, there is no consensus on the optimal approaches for simulation models and parameters. This study introduces a novel MRS digital brain phantom framework, providing a comprehensive and modular foundation for MRS data simulation. Methods: The framework generates a digital brain phantom by combining anatomical and tissue label information with metabolite data from the literature. This phantom contains all necessary information for simulating spectral data. The MRS phantom is combined with a signal‐based model to demonstrate its functionality and usability in generating various spectral datasets. Outputs can be saved in the NIfTI‐MRS format, enabling their use in downstream applications. To evaluate the realism of the simulated spectra, a comparison was performed against in vivo MRS data acquired under similar conditions. Results: The phantom was implemented using two anatomical templates at different resolutions and tested across a range of user‐defined simulation parameters. Simulated spectra exhibited realistic signal characteristics and structural variability. When compared to in vivo data, the simulated spectra closely matched in terms of spectral shape, signal‐to‐noise ratio, and metabolite quantification. The simulations also captured key variability features and provided additional diversity not present in the in vivo dataset, supporting use in robustness testing and data augmentation. Conclusion: This novel digital phantom provides a flexible and extensible platform for MRS data simulation. Its modular architecture, user‐friendly GUI, and open‐source implementation support reproducible research, algorithm development, and validation in the MRS community.

16 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
DSDennis M. J. van de Sande
Dennis M. J. van de Sande
JMJulian P. Merkofer
Julian P. Merkofer
SASina Amirrajab
Sina Amirrajab
MVMitko Veta
Mitko Veta
RSRuud J. G. van Sloun
Ruud J. G. van Sloun
MBMarcel Breeuwer
Marcel Breeuwer
This literature review presents a comprehensive overview of machine learning (ML) applications in proton magnetic resonance spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state-of-the-art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the magnetic resonance field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in-vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.

17 November 2026 in NMR in Biomedicine
Verified
Journal Article
Open access
JLJohn T. LaMaster
John T. LaMaster
AGAaron T. Gudmundson
Aaron T. Gudmundson
AAAlireza Abaei
Alireza Abaei
SASeyma Alcicek
Seyma Alcicek
AAArturo Alvarado
Arturo Alvarado
AKAntonia Kaiser
Antonia Kaiser
Synthetic data generation has become an increasingly important component of methodological development in magnetic resonance spectroscopy (MRS), particularly in contexts where ground‐truth in vivo measurements are limited, noisy, or inaccessible. This review provides a structured overview of current practices in synthetic MRS data generation, with emphasis on the physical, biochemical, and computational assumptions that underpin commonly used models. A decomposition of synthetic MRS data is presented in terms of core building blocks, including basis sets, signal formation models, and metabolite parameter distributions such as concentration and relaxation properties. This framework is extended to advanced components required for realistic data synthesis, including baseline and nuisance signals, spatial encoding effects such as coil sensitivities and field inhomogeneities, k‐space sampling and gradient imperfections, as well as sample‐specific and temporal dynamics. Beyond single‐voxel modeling, synthetic data generation across multiple MRS modalities is discussed, including functional MRS, diffusion‐weighted MRS, and spectroscopic imaging, with emphasis on modality‐specific challenges such as physiological variability, motion, and confounding signal contributions. The role of synthetic data in clinical and preclinical research, acquisition optimization, software validation, and emerging artificial intelligence applications is further examined, with particular attention to domain shift and representational realism. Current practices in validation, reporting standards, and data accessibility are also reviewed, and key gaps limiting reproducibility and interoperability across studies are identified. Overall, this work provides a unified conceptual framework for synthetic MRS data generation, clarifies underlying assumptions across modeling choices, and outlines open challenges toward improving realism, standardization, and utility in both methodological and translational applications. Conducted by the MRS Synthetic Data Working Group under the Code & Data Sharing Committee of the MRS Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM), this review encompasses the existing literature, supplemented by the collective experience and in‐house methodologies of its contributors, providing a community perspective that extends beyond the published record.