Joshua S. Holt

Joshua S. Holt

Auto-generated profile, based on publicly available information

Joshua S. Holt

College of Nanoscale Science and Engineering, University at Albany, State University of New York, Albany, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2017 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
ZAZahiruddin Alamgir
Zahiruddin Alamgir
KBKarsten Beckmann
Karsten Beckmann
JHJoshua Holt
Joshua Holt
NCNathaniel Cady
Nathaniel Cady
Mutli-level switching in resistive memory devices enables a wide range of computational paradigms, including neuromorphic and cognitive computing. To this end, we have developed a bi-layer tantalum oxide based resistive random access memory device using Hf as the oxygen exchange layer. Multiple, discrete resistance levels were achieved by modulating the RESET pulse width and height, ranging from 2 kΩ to several MΩ. For a fixed pulse height, OFF state resistance was found to increase gradually with the increase in the pulse width, whereas for a fixed pulse width, the increase in the pulse height resulted in drastic changes in resistance. Resistive switching in these devices transitioned from Schottky emission in the OFF state to tunneling based conduction in the ON state, based on I-V curve fitting and temperature dependent current measurements. These devices also demonstrated endurance of more than 108 cycles with a satisfactory Roff/Ron ratio and retention greater than 104 s.

13 June 2017 in MRS Advances
Verified
Journal Article
Closed access
PDF file
JHJoshua S. Holt
Joshua S. Holt
KBKarsten Beckmann
Karsten Beckmann
ZAZahiruddin Alamgir
Zahiruddin Alamgir
JYJean Yang-Scharlotta
Jean Yang-Scharlotta
NCNathaniel C. Cady
Nathaniel C. Cady

30 October 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JHJoshua S. Holt
Joshua S. Holt
ZAZahiruddin Alamgir
Zahiruddin Alamgir
KBKarsten Beckmann
Karsten Beckmann
NSNadia Suguitan
Nadia Suguitan
SRSierra Russell
Sierra Russell
NCNathaniel Cady
Nathaniel Cady
The radiation response of TaOx-based resistive memory (RRAM) devices fabricated in academic (Set A) and industrial (Set B) settings was compared. Ionization damage from a 60 Co gamma source did not cause any changes in device resistance for either device type, up to 45 Mrad(Si). Displacement damage from a heavy ion beam caused a decrease in resistance at 1× 10 21 oxygen displacements per cm 3 in Set B devices in the high-resistance state (HRS); meanwhile, Set A devices did not exhibit any decrease in resistance due to displacement damage. Both types of devices exhibited an increase in resistance around 3 × 10 22 oxygen displacements per cm 3 , possibly due to the damage at the oxide/metal interfaces. These extremely high levels of damage represent near-total atomic disruption, and if this level of damage was ever reached, other circuit elements would likely fail before the RRAM devices in this article. Overall, both sets of devices were much more resistant to radiation effects than the similar devices reported in the literature. Displacement damage effects were only observed in the Set A devices once the displacement-induced oxygen vacancies surpassed the intrinsic vacancy concentration in the devices, suggesting that high oxygen vacancy concentration played a role in the devices' high tolerance to displacement damage.

1 October 2015
Verified
Conference Paper
Closed access
JHJoshua Holt
Joshua Holt
NCNathaniel Cady
Nathaniel Cady
JYJean Yang-Scharlotta
Jean Yang-Scharlotta
Resistive memory (RRAM) is an emerging memory technology, expected to have inherent resistance to radiation damage. We present an initial study characterizing the effects of several types of radiation on a set of tantalum oxide-based RRAM devices. Gamma radiation (64.7 Mrad(Si)) was found to have no significant impact on switching properties. Likewise, ionic radiation (H, N, Ar+) up to 1015 ions/cm2 did not have any significant effect. This resistance to radiation, combined with high endurance and data retention, make RRAM an excellent candidate for use in harsh environments.