Thomas Urgert

Thomas Urgert

Auto-generated profile, based on publicly available information

Thomas Urgert

Department of Internal Medicine, Ziekenhuisgroep Twente, Almelo, the Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2024 in Interactive Journal of Medical Research
Verified
Journal Article
Open access
NBNiala Den Braber
Niala Den Braber
CBCarlijn Irene Raymond Braem
Carlijn Irene Raymond Braem
MVMiriam Vollenbroek-Hutten
Miriam Vollenbroek-Hutten
HHHermie Hermens
Hermie Hermens
TUThomas Urgert
Thomas Urgert
GLGozewijn Laverman
Gozewijn Laverman
Background: The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. Objective: We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. Methods: The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. Results: A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. Conclusions: With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. Trial Registration: ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293

13 October 2025 in BMJ Open
Verified
Journal Article
Open access
PDF file
TUThomas Urgert
Thomas Urgert
KKKilian Derk Rinse Kappert
Kilian Derk Rinse Kappert
AVAnouk Veldhuis
Anouk Veldhuis
JGJeroen Geerdink
Jeroen Geerdink
BBBernard Johannes Frederik van Beijnum
Bernard Johannes Frederik van Beijnum
GLGozewijn Laverman
Gozewijn Laverman
Introduction Advancements in technology for treating diabetes mellitus (DM) are progressing rapidly. With the growing availability and use of continuous glucose monitoring (CGM) systems and continuous subcutaneous insulin infusion (CSII), glucose regulation is improved in individuals with DM, which will lead to less long-term complications and reduce the overall disease burden on patients with DM. Collecting vast amount of biomedical data, these devices combined with clinical outcome data provide more insight into the development and treatment of the disease. The objective of the DIABASE initiative is to collect and examine real-world data from medical devices and clinical practice in a registry. Methods and analysis The ongoing study is structured as an observational study registry. Clinical data and real-world data from diabetes wearable devices, such as CGM and CSII, are aggregated in the database. Clinical data is automatically extracted from the hospital’s electronic health record. Data from wearables is periodically collected manually from the various online data platforms for sharing and automatically added to the database. Ethics and dissemination This study is exempted from ethics approval by the Medical Research Ethics Committees United (MEC-U) since participants are not subject to procedures and are not required to follow rules of behaviour (approval ID: AW23.009/W20.197). The execution of this study has been approved by the board of the study site Hospital Group Twente (ZGT) (ZGT20-40). Results will be shared through scientific meetings and publications and through articles for the general public. Trial registration number NCT05584293; Pre-results.

14 July 2023 in JMIR Preprints
Verified
Preprint
Open access
NBNiala Den Braber
Niala Den Braber
CBCarlijn Irene Raymond Braem
Carlijn Irene Raymond Braem
MVMiriam Vollenbroek-Hutten
Miriam Vollenbroek-Hutten
HHHermie Hermens
Hermie Hermens
TUThomas Urgert
Thomas Urgert
GLGozewijn Laverman
Gozewijn Laverman
BACKGROUND The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. OBJECTIVE We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. METHODS The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. RESULTS A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. CONCLUSIONS With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. CLINICALTRIAL ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293