Jeremy Rubin

Jeremy Rubin

Auto-generated profile, based on publicly available information

Jeremy Rubin

Department of Epidemiology and Biostatistics, School of Public Health, University of Maryland, College Park, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2025 in Stroke
Verified
Journal Article
Closed access
JSJae W. Song
Jae W. Song
HPHuy Q. Phi
Huy Q. Phi
MKManisha Koneru
Manisha Koneru
QCQuy Xuan Cao
Quy Xuan Cao
JRJeremy Rubin
Jeremy Rubin
BCBrett L. Cucchiara
Brett L. Cucchiara
BACKGROUND: A modified computed tomography angiography (CTA)–based Carotid Plaque Reporting and Data System (Plaque-RADS) classification was applied to a cohort of patients with embolic stroke of undetermined source to test whether high-risk Plaque-RADS subtypes are more prevalent on the ipsilateral side of stroke. With the widespread use of CTA for stroke evaluation, a CTA-based Plaque-RADS would be valuable for generalizability. METHODS: A retrospective observational cross-sectional study was conducted at a single integrated health system comprised of 3 hospitals with a comprehensive stroke center between October 1, 2015, and April 1, 2017. Patients with unilateral anterior circulation stroke and <50% carotid stenosis on CTA were retrospectively identified. Maximum plaque thickness and ulceration were assessed by a neuroradiologist blinded to the stroke side. A semiautomated segmentation software measured intraplaque hemorrhage volumes. Modified CTA-based Plaque-RADS classification was defined as (1) no plaque, (2) plaque thickness 50 mm 3 irrespective of plaque thickness. High-risk plaque subtypes (Plaque-RADS 3 and 4) were compared with low-risk subtypes (Plaque-RADS 1 and 2). RESULTS: Ninety-four patients (55% women; median age, 66 years) were included. CTA-based Plaque-RADS categories for plaques ipsilateral to the stroke side were as follows: (1) 14.9%, (2) 42.6%, (3) 41.5%, and (4) 1.1%. Carotid plaques contralateral to stroke side were Plaque-RADS: (1) 21.3%, (2) 46.8%, (3) 31.9%, and (4) 0%. When compared with the contralateral side, plaques ipsilateral to the stroke side were significantly associated with high-risk Plaque-RADS subtypes in a mixed-effects logistic model adjusting for age and sex (adjusted odds ratio, 2.10 [95% CI, 1.20–3.71]; P =0.01). CONCLUSIONS: Carotid plaque ipsilateral to the stroke side was significantly associated with CTA-based high-risk Plaque-RADS subtypes in an embolic stroke of undetermined source cohort. A CTA-based Plaque-RADS classification may be useful for identifying potentially causative carotid plaque phenotypes in patients with embolic stroke of undetermined source.

5 April 2023 in Kidney360
Verified
Journal Article
Open access
YCYijiang Chen
Yijiang Chen
JZJarcy Zee
Jarcy Zee
AJAndrew R. Janowczyk
Andrew R. Janowczyk
JRJeremy Rubin
Jeremy Rubin
PTPaula Toro
Paula Toro
LBLaura Barisoni
Laura Barisoni
Key Points: Computational image analysis allows for the extraction of new information from whole-slide images with potential clinical relevance. Peritubular capillary (PTC) density is decreased in areas of interstitial fibrosis and tubular atrophy when measured in interstitial fractional space. PTC shape (aspect ratio) is associated with clinical outcome in glomerular diseases. Background: The association between peritubular capillary (PTC) density and disease progression has been studied in a variety of kidney diseases using immunohistochemistry. However, other PTC attributes, such as PTC shape, have not been explored yet. The recent development of computer vision techniques provides the opportunity for the quantification of PTC attributes using conventional stains and whole-slide images. Methods: To explore the relationship between PTC characteristics and clinical outcome, n=280 periodic acid–Schiff-stained kidney biopsies (88 minimal change disease, 109 focal segmental glomerulosclerosis, 46 membranous nephropathy, and 37 IgA nephropathy) from the Nephrotic Syndrome Study Network digital pathology repository were computationally analyzed. A previously validated deep learning model was applied to segment cortical PTCs. Average PTC aspect ratio (PTC major to minor axis ratio), size (PTC pixels per PTC segmentation), and density (PTC pixels per unit cortical area) were computed for each biopsy. Cox proportional hazards models were used to assess associations between these PTC parameters and outcome (40% eGFR decline or kidney failure). Cortical PTC characteristics and interstitial fractional space PTC density were compared between areas of interstitial fibrosis and tubular atrophy (IFTA) and areas without IFTA. Results: When normalized PTC aspect ratio was below 0.6, a 0.1, increase in normalized PTC aspect ratio was significantly associated with disease progression, with a hazard ratio (95% confidence interval) of 1.28 (1.04 to 1.59) (P = 0.019), while PTC density and size were not significantly associated with outcome. Interstitial fractional space PTC density was lower in areas of IFTA compared with non-IFTA areas. Conclusions: Computational image analysis enables quantification of the status of the kidney microvasculature and the discovery of a previously unrecognized PTC biomarker (aspect ratio) of clinical outcome.

5 December 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
YSYu Sakai
Yu Sakai
QCQuy Xuan Cao
Quy Xuan Cao
JRJeremy Rubin
Jeremy Rubin
JWJens Witsch
Jens Witsch
DCDan Cohen‐Addad
Dan Cohen‐Addad
JSJae W. Song
Jae W. Song
Background: Complex aortic plaque (CAP) is a potential embolic source in patients with cryptogenic stroke (CS). We review CAP imaging criteria for transesophageal echocardiogram (TEE), computed tomography angiography (CTA), and magnetic resonance imaging and calculate CAP prevalence in patients with acute CS. Methods and Results: PubMed and EMBASE databases were searched up to December 2022 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guideline. Two independent reviewers extracted data on study design, imaging techniques, CAP criteria, and prevalence. The Cochrane Collaboration tool and Guideline for Reporting Reliability and Agreement Studies were used to assess risk of bias and reporting completeness, respectively. From 2293 studies, 45 were reviewed for CAP imaging biomarker criteria in patients with acute CS (N=37 TEE; N=9 CTA; N=6 magnetic resonance imaging). Most studies (74%) used ≥4 mm plaque thickness as the imaging criterion for CAP although ≥1 mm (N=1, CTA), ≥5 mm (N=5, TEE), and ≥6 mm (N=2, CTA) were also reported. Additional features included mobility, ulceration, thrombus, protrusions, and assessment of plaque composition. From 23 prospective studies, CAP was detected in 960 of 2778 patients with CS (0.32 [95% CI, 0.24–0.41], I 2 =94%). By modality, prevalence estimates were 0.29 (95% CI, 0.20–0.40; I 2 =95%) for TEE; 0.23 (95% CI, 0.15–0.34; I 2 =87%) for CTA and 0.22 (95% CI, 0.06–0.54; I 2 =92%) for magnetic resonance imaging. Conclusions: TEE was commonly used to assess CAP in patients with CS. The most common CAP imaging biomarker was ≥4 mm plaque thickness. CAP was observed in one‐third of patients with acute CS. However, high study heterogeneity suggests a need for reproducible imaging methods.

30 January 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JRJeremy S. Rubin
Jeremy S. Rubin
ESEric L. Shirley
Eric L. Shirley
ZLZachary H. Levine
Zachary H. Levine
We have significantly accelerated diffraction calculations using three independent acceleration devices. These innovations are restricted to cylindrically symmetrical systems. In the first case, we consider Wolf’s formula for integrated flux in a circular region following diffraction of light from a point source by a circular aperture or a circular lens. Although the formula involves a double sum, we evaluate it with the effort of a single sum by use of fast Fourier transforms (FFTs) to perform convolutions. In the second case, we exploit properties of the Fresnel–Kirchhoff propagator in the Gaussian, paraxial optics approximation to achieve the propagation of a partial wave from one optical element to the next. Ordinarily, this would involve a double loop over the radial variables on each element, but we have reduced the computational cost by a factor approximately equal to the smaller number of radius values. In the third case, we reduce the number of partial waves, for which the propagation needs to be calculated, to determine the throughput of an optical system of interest in radiometry when at least one element is very small, such as a pinhole aperture. As a demonstration of the benefits of the second case, we analyze intricate diffraction effects that occur in a satellite-based solar radiometry instrument.

30 July 2026 in Health Services and Outcomes Research Methodology
Verified
Journal Article
Open access
PDF file
JRJeremy Rubin
Jeremy Rubin
LARRY HANLARRY HAN
LARRY HAN
JZJarcy Zee
Jarcy Zee
Accurate prediction of clinical outcomes and a reliable assessment of the uncertainty around those predictions are critical for informed decision-making in medicine. Yet, as black-box machine learning algorithms are increasingly deployed for complex biomedical prediction tasks, their lack of robust uncertainty quantification, especially in small samples, rare diseases, and underrepresented groups, has led to overconfident predictions and adverse outcomes. Conformal quantile regression (CQR) offers a distribution-free, model-agnostic framework that generates finite-sample valid prediction intervals, ensuring reliable coverage guarantees regardless of the underlying ML algorithm. While CQR has been applied in various prediction tasks, it has not been explored in the context of predicting estimated glomerular filtration rate (eGFR) using high-dimensional image-derived regressors, such as features extracted from kidney biopsy images. In this study, we investigate the utility of CQR for predicting eGFR, a key biomarker of kidney function, by integrating demographic, clinical, and image data. Through simulation studies, we demonstrate that CQR maintains reliable coverage even when predictions are constructed from generated regressors subject to additive measurement error, although larger sample sizes are necessary when regressors are functionally misspecified. Finally, we apply CQR to real-world glomerular disease kidney biopsy image features and show that it produces well-calibrated prediction intervals for future eGFR measurements, addressing a critical gap in quantifying predictive uncertainty in complex biomedical models.

5 March 2025 in Statistics in Biosciences
Verified
Journal Article
Open access
PDF file
JRJeremy Rubin
Jeremy Rubin
FFFan Fan
Fan Fan
LBLaura Barisoni
Laura Barisoni
AJAndrew R. Janowczyk
Andrew R. Janowczyk
JZJarcy Zee
Jarcy Zee
Image features that characterize tubules from digitized kidney biopsies may offer insight into disease prognosis as novel biomarkers. For each subject, we can construct a matrix whose entries are a common set of image features (e.g., area, orientation, eccentricity) that are measured for each tubule from that subject’s biopsy. Previous scalar-on-matrix regression approaches which can predict scalar outcomes using image feature matrices cannot handle varying numbers of tubules across subjects. We propose the CLUstering Structured laSSO (CLUSSO), a novel scalar-on-matrix regression technique that allows for unbalanced numbers of tubules, to predict scalar outcomes from the image feature matrices. Through classifying tubules into one of two different clusters, CLUSSO averages and weights tubular feature values within-subject and within-cluster to create balanced feature matrices that can then be used with structured lasso regression. We develop the theoretical large tubule sample properties for the error bounds of the feature coefficient estimates. Simulation study results indicate that CLUSSO often achieves a lower false positive rate and higher true positive rate for identifying the image features which truly affect outcomes relative to a naive method that averages feature values across all tubules. Additionally, we find that CLUSSO has lower bias and can predict outcomes with a competitive accuracy to the naïve approach. Finally, we applied CLUSSO to tubular image features from kidney biopsies of glomerular disease subjects from the Nephrotic Syndrome Study Network (NEPTUNE) to predict kidney function and used subjects from the Cure Glomerulonephropathy (CureGN) study as an external validation set.