Introduction Impaired awareness of hypoglycemia, clinically reflected by the inability to timely detect hypoglycemia, affects approximately 25% of the people with type 1 diabetes. Both altered brain lactate handling and increased cerebral blood flow (CBF) during hypoglycemia appear to be involved in the pathogenesis of impaired awareness of hypoglycemia. Here we examine the effect of lactate on CBF during hypoglycemia. Research design and methods Nine people with type 1 diabetes and normal awareness of hypoglycemia underwent two hyperinsulinemic euglycemic-hypoglycemic (3.0 mmol/L) glucose clamps in a 3T MR system, once with sodium lactate infusion and once with sodium chloride infusion. Global and regional changes in CBF were determined using pseudocontinuous arterial spin labeling. Results Lactate (3.3±0.6 vs 0.9±0.2 mmol/L during lactate infusion vs placebo infusion, respectively) suppressed the counter-regulatory hormone responses to hypoglycemia. Global CBF increased considerably in response to intravenous lactate infusion but did not further increase during hypoglycemia. Lactate also blunted the hypoglycemia-induced regional redistribution of CBF towards the thalamus. Conclusions Elevated lactate levels enhance global CBF and blunt the thalamic CBF response during hypoglycemia in patients with type 1 diabetes, mimicking observations of impaired awareness of hypoglycemia. These findings suggest that alteration of CBF associated with lactate may play a role in some aspects of the development of impaired awareness of hypoglycemia. Trial registration number NCT03730909.
The use of methylsulfonylmethane (MSM), available as an “over-the-counter” dietary supplement, led to the occurrence of an abnormal resonance at 3.15 ppm in the in vivo brain proton MR spectrum as well as the in vitro cerebrospinal fluid NMR study of a 4-year-old girl. The concentration of this compound amounted to 1.2 mmol/l in brain tissue and 1.7 mmol/l in cerebrospinal fluid. Our findings illustrate that ingestion of exogenous compounds, e.g., in medication, food or “innocent” supplements, may lead to abnormal resonances in spectroscopy studies that might be difficult to assign.
The use of 3T MRI in patients with bilateral deep brain stimulation (DBS) leads is limited by safety concerns due to radiofrequency (RF) heating. A promising strategy to overcome this problem involves RF shimming using low‐specific absorption rate (SAR) calibration scans to estimate the RF‐induced currents based on image artifacts near the leads. Although clinically available two‐channel RF shimming can suppress RF heating in a single lead configuration, complete nulling is not possible when more than one lead is involved. This study aims to develop a method to minimize rather than null RF heating and optimize imaging performance during 3T MRI in a bilateral DBS lead configuration by using two‐channel RF shimming. An anthropomorphic phantom equipped with bilateral DBS leads and fiber‐optic temperature sensors was constructed. Optimal RF shim settings were determined in multiple phantom orientations using a low‐SAR calibration protocol. These settings were evaluated and compared with the quadrature mode by measuring local RF heating during a high‐SAR imaging sequence and inspecting residual image artifacts. Measured heating curves and imaging data confirmed that tailored RF shim settings minimized RF heating and image artifacts for both leads simultaneously in all orientations studied. Two‐channel RF shimming on a clinical 3T MRI scanner can thus be optimized in a bilateral DBS lead configuration to minimize RF heating and maximize imaging performance. This workflow could potentially enable a patient‐specific workflow for safe imaging in patients with bilateral DBS leads at 3T.