Jose Eduardo Freire

Jose Eduardo Freire

Auto-generated profile, based on publicly available information

Jose Eduardo Freire

Physics, University of Sao Paulo Faculty of Philosophy Sciences and Letters of Ribeirao Preto, Av. Bandeirantes, 3900 - Monte Alegre, Ribeirao Preto, SP, 14040-901, BRAZIL

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EVErnesto Edgar Mazon Valadez
Ernesto Edgar Mazon Valadez
RBRicardo R. Bordonal
Ricardo R. Bordonal
JFJosé E. Freire
José E. Freire
JUJoão Uliana
João Uliana
SASaeideh Arsalani
Saeideh Arsalani
Theo PavanTheo Pavan
Theo Pavan
Magnetomotive ultrasound (MMUS) stands out as a promising and effective ultrasound-based method for detecting magnetic nanoparticles (MNPs) within tissues. This innovative technique relies on the precise estimation of micrometric displacements induced by the interaction of an external magnetic field with MNPs. Pulsed MMUS has emerged as a strategic alternative to address limitations associated with harmonic excitation, such as heat generation in amplifiers and coils, frequency-dependent tissue mechanical responses, and prolonged magnetic field rise times. Despite the growing interest in MMUS, the devices conventionally employed to excite the coil are not specifically tailored to generate intense magnetic fields while minimizing interference with the transient behavior of induced displacements. To bridge this gap, our work introduces the design and fabrication of two pulse generators: one based on a capacitor-discharge circuit and the other on a resonant-inverter circuit. We evaluated the performance of these pulse generators by considering parameters such as the magnetic field generated, rise and fall times, and their ability to supply sustained current for varied pulse widths across different pulse repetition frequencies. Furthermore, we carried out a practical MMUS implementation using tissue-mimicking phantoms, demonstrating the capability of both devices to achieve magnetic fields of up to 1 T and average displacements of 25 µm within the phantom. In addition, we estimated the shear wave velocity, effective shear modulus, and their temperature-dependent variations. Our findings highlight the versatility and efficacy of the proposed pulse generators and emphasize their potential as low-cost platforms for theranostic applications, enabling the assessment of targeted entities within biological tissues.

6 November 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JFJose E Freire
Jose E Freire
David Alejandro Collazos-BurbanoDavid Alejandro Collazos-Burbano
David Alejandro Collazos-Burbano
JUJoao H Uliana
Joao H Uliana
NZNicholas Zufelato
Nicholas Zufelato
ACAntonio A O Carneiro
Antonio A O Carneiro
Theo PavanTheo Pavan
Theo Pavan
Objective. Magnetic hyperthermia (MH) has proven effective as an ablative therapy in oncology through the use of magnetic nanoparticles (MNPs), whereas magnetomotive ultrasound (MMUS) has emerged as a promising technique for detecting MNPs and conducting elastographic assessments. However, integrated strategies that leverage MNPs both for localized heating via MH and for quantification of treatment-induced viscoelastic changes using MMUS remain largely unexplored. This study proposes a theranostic approach that combines thermal ablation via MH with the simultaneous quantification of viscoelastic properties through MMUS. Approach. A pulsed magnetic field was applied to induce displacements and assess viscoelasticity using MMUS, while an alternating radiofrequency magnetic field was used to generate MH. A force-independent formulation based on the Kelvin–Voigt model was used to estimate viscoelastic parameters, first in tissue-mimicking phantoms for validation using benchmark methods, and subsequently in ex-vivo bovine liver to evaluate the effects of MH. Main results. Notably, no a priori knowledge of MNPs distribution was required to quantify MH-induced changes. The elastic and viscous components, along with the damping ratio, were identified as suitable MMUS-derived markers to characterize tissue alterations due to MH. The elastic parameter increased by at least 35% after MH, indicating that higher thermal doses correlate with greater elastic stiffening. Moreover, even in the case where tissue elasticity remained unchanged, the viscous property and damping ratio still exhibited increases of at least 100% relative to pre MH values, underscoring the sensitivity of these parameters to thermally induced changes in tissue viscosity. Significance. The findings demonstrate the potential of integrating MH and MMUS for real-time monitoring and quantification of treatment effects in oncology. Furthermore, this approach may enhance our understanding of the interplay between tissue viscoelasticity and water diffusion following MH, supporting the full use of viscoelastic parameters as clinical biomarkers.

23 May 2026 in ACS Applied Nano Materials
Verified
Journal Article
Open access
JMJulia Mendonça Margatho
Julia Mendonça Margatho
TVThiago Tiburcio Vicente
Thiago Tiburcio Vicente
JFJose Eduardo Freire
Jose Eduardo Freire
Theo PavanTheo Pavan
Theo Pavan
JCJuliana Cancino-Bernardi
Juliana Cancino-Bernardi