Kun Wang

Kun Wang

Auto-generated profile, based on publicly available information

Kun Wang

Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2025 in BMJ Open
Verified
Journal Article
Open access
PDF file
MLMeilin Li
Meilin Li
RLRong-Bin Liang
Rong-Bin Liang
YZYulu Zhou
Yulu Zhou
KWKun Wang
Kun Wang
RYRundong Yang
Rundong Yang
XZXiaodong Zhou
Xiaodong Zhou
Objectives The prevalence of myopia has been rising, whereas prevention efforts have shown limited success. Educational short videos have become crucial sources for health information; however, their quality regarding myopia prevention is uncertain. This study aimed to evaluate the quality and content of short videos on myopia prevention disseminated via major Chinese short video platforms and compare content differences between healthcare professionals and non-professional creators. Design A cross-sectional content analysis. Setting Top-ranked videos from three dominant Chinese platforms (TikTok, Kwai and BiliBili) in 6–10 August 2024. Participants 284 eligible videos screened from 300 initial results using predefined exclusion criteria, including 97 videos from TikTok, 94 from BiliBili and 93 from Kwai. Methods Videos were assessed using the Global Quality Scale and a modified DISCERN tool. Content completeness was evaluated across six predefined domains. Videos were categorised by source (healthcare professionals vs non-healthcare professionals), and intergroup differences were statistically analysed. Results Of the 284 videos, 48.9% were uploaded by healthcare professionals and 51.1% by non-healthcare professionals. Overall video quality was suboptimal. Videos by ophthalmologists had significantly higher quality scores than those by other creators. Healthcare professionals focused more on definitions, symptoms and risk factors of myopia, whereas non-healthcare professionals emphasised prevention and treatment outcomes. Ophthalmologists more frequently recommended corrective lenses (including both standard spectacles and specially designed lenses for myopia control) and low-dose atropine, whereas non-healthcare professionals favoured vision training. Conclusions Significant quality gaps exist in myopia prevention videos. Healthcare professionals, particularly ophthalmologists, produce higher-quality and more comprehensive content. Strategic engagement by healthcare professionals in digital health communication and platform-level quality control is needed to improve public health literacy on myopia.

31 October 2025 in Medicine
Verified
Journal Article
Open access
QZQiuhua Zhang
Qiuhua Zhang
ASAi’ZHu Sheng
Ai’ZHu Sheng
HRHong Ren
Hong Ren
KWKun Wang
Kun Wang
Coronary CT angiography (CCTA) in obese patients is challenging due to high radiation exposure, elevated iodine load, and increased image noise. We evaluated a tripartite low-dose strategy combining high-iodine-concentration contrast media (HCM, 400 mgI/mL), 80-kVp scanning, and deep learning image reconstruction (DLIR) in obese patients (BMI ≥30 kg/m 2 ) to simultaneously reduce radiation and iodine dose while maintaining diagnostic quality. In this prospective, single-center trial, 100 obese patients were randomized to either a low-dose group (80 kVp, HCM at 0.6 mL/kg, DLIR reconstruction; n = 50) or a standard-dose group (120 kVp, 350 mgI/mL contrast at 0.9 mL/kg, adaptive statistical iterative reconstruction [ASiR]-V 50% reconstruction; n = 50). Low-dose scans were also reconstructed with ASiR-V 50% for internal comparison. Objective (noise, signal-to-noise ratio, contrast-to-noise ratio) and subjective (5-point scale by blinded radiologists) image quality, radiation dose, total iodine load, and diagnostic performance (vs invasive coronary angiography in a 20-patient subgroup) for detecting ≥50% stenosis were compared. The low-dose protocol significantly reduced effective radiation dose by 48.6% (1.06 ± 0.26 mSv vs 2.27 ± 0.42 mSv; P <.001) and total iodine load by 23.8% (19.2 ± 2.1 gI vs 25.2 ± 2.4 gI; P <.001) compared to standard protocol. DLIR at 80-kVp significantly reduced image noise (aortic root: 16.5 ± 3.0 HU vs 25.1 ± 4.0 HU for ASiR-V at 80 kVp; P <.001) and improved contrast-to-noise ratio (e.g., proximal left anterior descending: +41.6%, P <.001) and signal-to-noise ratio (e.g., distal right coronary artery: +63.8%, P <.001). Subjective image quality scores were significantly higher for DLIR (mean 4.4 ± 0.5) versus low-dose ASiR-V (3.0 ± 0.7) and standard-dose ASiR-V (4.1 ± 0.7; P <.001), with excellent inter-observer agreement (κ = 0.88). 94% of DLIR datasets received optimal noise scores (≥4/5) versus 0% for low-dose ASiR-V. Against invasive coronary angiography, the low-dose protocol achieved 100% patient-level sensitivity and negative predictive value, with 91.7% vessel-level accuracy. Combining HCM, 80-kVp scanning, and DLIR significantly reduces radiation exposure and iodine load in obese CCTA patients without compromising image quality or diagnostic accuracy compared to standard protocols, offering a safer alternative, particularly for patients with renal impairment.