Martin C. Fischer

Martin C. Fischer

Auto-generated profile, based on publicly available information

Martin C. Fischer

Department of Chemistry, Duke University, Durham, NC 27708, USA

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
EFEmma P. Fischer
Emma P. Fischer
MFMartin C. Fischer
Martin C. Fischer
DGDavid Grass
David Grass
IHIsaac Henrion
Isaac Henrion
WWWarren S. Warren
Warren S. Warren
EWEric Westman
Eric Westman
A simple method was developed for evaluating the efficacy of face masks to reduce respiratory droplet emission during speaking.

1 March 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MFMartin C. Fischer
Martin C. Fischer
JWJesse W. Wilson
Jesse W. Wilson
FRFrancisco E. Robles
Francisco E. Robles
WWWarren S. Warren
Warren S. Warren
Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing single-color techniques and allow for structural and functional imaging without the need for exogenous dyes and labels, which might interfere with the system under study. In this review, we provide a tutorial overview, covering principles of pump-probe microscopy and experimental setup, challenges associated with signal detection and data processing, and an overview of applications.

5 June 1997 in Nature
Verified
Journal Article
Closed access
SWSteven R. Wilkinson
Steven R. Wilkinson
CBCyrus F. Bharucha
Cyrus F. Bharucha
MFMartin C. Fischer
Martin C. Fischer
KMKirk W. Madison
Kirk W. Madison
PMPatrick R. Morrow
Patrick R. Morrow
MRMark G. Raizen
Mark G. Raizen

7 December 1998 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
KMK. W. Madison
K. W. Madison
MFM. C. Fischer
M. C. Fischer
RDR. B. Diener
R. B. Diener
QNQian Niu
Qian Niu
MRM. G. Raizen
M. G. Raizen
Dynamical Bloch band suppression is observed for the first time, using cold sodium atoms in a far detuned standing wave of light. This system has well-defined Bloch bands as its energy spectrum, which are modified dynamically by imposing a strong phase modulation of the standing wave. The atoms are prepared in the lowest band, and the spectrum is mapped out by introducing a weak spectroscopic probe that drives transitions between the modified bands. Dynamical suppression of the bands is observed at a critical value of the modulation strength, and is well supported by a full quantum mechanical analysis that goes beyond the single-band and tight-binding approximations.

30 November 2018 in ACS Nano
Verified
Journal Article
Closed access
KJKuk-Youn Ju
Kuk-Youn Ju
MFMartin C. Fischer
Martin C. Fischer
WWWarren S. Warren
Warren S. Warren

23 September 2004 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MFM.C. Fischer
M.C. Fischer
ZSZ.Z. Spector
Z.Z. Spector
MIM. Ishii
M. Ishii
JYJ. Yu
J. Yu
KEK. Emami
K. Emami
RRR. Rizi
R. Rizi
Magnetic resonance imaging (MRI) with hyperpolarized 3‐helium gas (HP 3He) offers the possibility of studying functional lung parameters such as the alveolar oxygen concentration and oxygen depletion rate. Until now, a double‐acquisition technique has been utilized to extract these parameters. A complicated single‐acquisition technique was previously developed to avoid the necessity of performing two identical breathing maneuvers. The results obtained with this technique were significantly less accurate than the results obtained with the double‐acquisition method. In this work, a novel, easily implemented single‐acquisition sequence is presented that provides results comparable to those obtained with the established double‐acquisition method. This method is demonstrated in a phantom and a pig model on a 1.5 T scanner using a 2D fast low‐angle shot (FLASH) gradient‐echo sequence. Numerical simulations of the time evolution of the oxygen concentration were performed. Simulation results are presented to support the experimental data. Various parameter regimes were experimentally and numerically investigated. Magn Reson Med 52:766–773, 2004.