This paper studies the estimation of harmonic contribution and harmonic source current for the system with multiple harmonic sources (SMHS). Firstly, the limitation of voltage projection (VP) theory in the SMHS is analyzed. In this regard, this paper proposes an indicator for quantifying harmonic contribution based on the harmonic source current. Then, this paper clarifies the difference between measured harmonic emission current and unmeasurable harmonic source current, and proposes a harmonic current estimation algorithm based on the minimum mutual information (MMI) principle and the Bayesian optimization (BO). The effectiveness of the proposed indicator and algorithm is verified through simulation and experiment.
A high sensitive micro-seismic fiber Bragg grating (FBG) sensor system based on narrow line width distributed feedback (DFB) laser is realized by using filtering demodulation. Sensitivity of micro-seismic FBG sensor lies on the structure of the sensor shell and the shape of the reflectivity spectrum of FBG. Experiments on the sensor system's frequency character have been done. Results show that this sensor has the smallest acceleration of 1mm/s2. The experiments on coal mine exhibit that the sensor can be used to measure micro-seismic sigmals. So the FBG sensor is feasible to have practical use to measure micro-seismic signals because the sensor has high sensitivity and is easy to be fabricated, it has good low frequency response and the interrogation system is simple, low cost
Large alumina electrolysis baths operate at high electrical current and high temperature hence a number of safety hazards. Conventional safety inspection relies on manual temperature monitoring using IR remote thermometers, which is not in real time and not reproducible. This paper presents a distributed fiber optic temperature sensor (DTS) system based on Raman scattering principle. The operation principle and method of deployment of the DTS system in an alumina electrolysis base and on-site monitoring results are discussed. The field measurement results show that the accuracy of the measurement of the distributed fiber optic temperature measurement system meets the application requirements and have great application potential.
A linear self-reference spectral interferometry has been proposed to measure the distribution of polarization-maintaining photonic crystal fiber (PM-PCF) birefringence over a wide wavelength range combined with the soliton self-frequency shift and birefringence effect. The birefringence of PM-PCF is measured experimentally over the range of 800-970 nm, which is larger than 5×10-4 and shows a segmented change trend. The air micropore structure has a significant effect on the characteristics of PM-PCF, which makes it have a highly nonlinear coefficient, and at the same time, changes the dispersion and birefringence distributions of the PM-PCF. The distribution of PM-PCF birefringence, measured by experiment, provides a new dimension for the design of PM-PCF, which is helpful for a detailed fiber model and an iterative optimization of fiber structure.