Purpose: To compare digitally fabricated complete dentures to conventionally fabricated dentures using patient‐ and clinician‐reported outcome measures. Methods: This review was structured according to PRISMA guidelines with the protocol registered in the PROSPERO database (CRD42024526069). An electronic search of the databases with a defined search strategy was completed within PubMed/MEDLINE and Web of Science from January 2000 to March 2024. Grey literature and article references were searched. Articles were screened by title and abstract, and the remaining articles were screened by full‐text review. Articles accepted for inclusion were subjected to a risk‐of‐bias assessment using Cochrane Collaboration tools (RoB 2 and ROBINS‐I). Results: From an initial pool of 704 articles, 15 studies met the selection criteria, of which the majority were published within the past 3 years. Within the included studies, there was inconsistency in the assessment methods of patient‐ and clinician‐reported outcomes, making it challenging to draw definitive conclusions. Generally, digital dentures had superior cost‐effectiveness and prosthesis fabrication time. Patient satisfaction and denture quality were not consistently improved with digital technology. Conclusions: Studies showed indications of patient satisfaction with digital and conventional dentures. Digital technology may enhance clinical workflows. A trend emerged that milled dentures performed better than printed dentures. Clinicians adopting digital technology into removable prosthodontics may have a learning curve to overcome, and they should consider the patient‐clinician relationship in addition to clinical outcomes to achieve patient satisfaction. Additional studies with standardized tools for assessing patient satisfaction are required to enable meaningful comparisons between digital and conventional workflows.
Purpose: This study aims to evaluate the accuracy of fit of full‐arch implant titanium frameworks fabricated from a fully digital workflow using a novel micro‐CT measurement technique. Materials and Methods: A 3D‐printed model with four implant analogs was fabricated. A baseline micro‐CT was obtained after placing temporary cylinders on the model. Next, the printed model was scanned with an intraoral scanner (TRIOS 5), and the STL files were used to fabricate 10 titanium frameworks. Each framework was placed back on the model, and another micro‐CT was taken under two conditions: single screw test (SST‐CT) and final fit test (FFT‐CT), and the measurements were compared to the baseline. Framework passivity was evaluated using a single‐screw test (SST) and a screw‐resistance test (SRT). The accuracy of the intraoral scans was assessed by superimposing the 10 scans with a laboratory scan STL to determine if the misfit was due to scanning or milling and designing errors. Results: None of the frameworks was deemed acceptable using SST‐CT, and only three had an acceptable fit using FFT‐CT. SST and SRT non‐passivity rates were 60% and 80%, respectively. Superimposition analysis revealed that only two intraoral scans used for framework fabrication fell within the acceptable deviation range of 150 microns, suggesting a high tendency for scanning errors and a possible milling or designing error in two samples. Conclusion: The results show a significant level of misfit. This suggests that the full‐digital workflow for full‐mouth rehabilitation can present some limitations. Due to the rapid advancement in intraoral scanning, further studies are required to validate these findings.
This article presents three cases outlining the benefits of utilizing a combination of digital and conventional workflows for the fabrication of immediate complete dentures. This combined digital and conventional approach addresses the recording of denture border extensions, digital articulation, and fabrication of complete dentures.