Young Jin Choi

Young Jin Choi

Auto-generated profile, based on publicly available information

Young Jin Choi

Department of Nanotechnology & Advanced Materials Engineering, Sejong University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2015 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
EYEun Ji Yoo
Eun Ji Yoo
MLMiaoqiang Lyu
Miaoqiang Lyu
Jung-Ho YunJung-Ho Yun
Jung-Ho Yun
CKChi Jung Kang
Chi Jung Kang
YCYoung Jin Choi
Young Jin Choi
Liang WangLiang Wang
Liang Wang

27 July 2016 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
EYEunji Yoo
Eunji Yoo
MLMiaoqiang Lyu
Miaoqiang Lyu
Jung-Ho YunJung-Ho Yun
Jung-Ho Yun
CKChijung Kang
Chijung Kang
YCYoungjin Choi
Youngjin Choi
Liang WangLiang Wang
Liang Wang
A simple organolead perovskite based device Ag/CH 3 NH 3 PbI 3−x Cl x /FTO exhibits both digital and analog switching memory features.

23 December 2007 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
JJJae Eun Jang
Jae Eun Jang
SCSeung Nam Cha
Seung Nam Cha
YCYoung Jin Choi
Young Jin Choi
Dae Joon KangDae Joon Kang
Dae Joon Kang
TBTim P Butler
Tim P Butler
GAGehan Amaratunga
Gehan Amaratunga

7 January 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SSSung Hyuk Sunwoo
Sung Hyuk Sunwoo
JLJu Seung Lee
Ju Seung Lee
SBSungJun Bae
SungJun Bae
YSYiel Jae Shin
Yiel Jae Shin
CKChang Seong Kim
Chang Seong Kim
Tae-Il KimTae-Il Kim
Tae-Il Kim
Significance: In this paper, we designed a flexible electrophysiological probe that could be implanted in the adrenal gland of a living animal. It allowed us to measure the electrophysiological signals of the adrenal gland in response to stress hormone release induced by acute stress. This report collects electrophysiological signals of the adrenal gland in vivo with chronic implantation.

12 February 2019 in ACS Photonics
Verified
Journal Article
Closed access
SYSang Hyun Yoon
Sang Hyun Yoon
DGDham Gwak
Dham Gwak
HKHong Hee Kim
Hong Hee Kim
HWHwi Je Woo
Hwi Je Woo
JCJinhee Cho
Jinhee Cho
YCYoung Jin Choi
Young Jin Choi

9 August 2019 in Nanotechnology
Verified
Journal Article
Closed access
KKKyu Young Kim
Kyu Young Kim
SYSang Hyun Yoon
Sang Hyun Yoon
IKIl Ku Kim
Il Ku Kim
HKHong Gyun Kim
Hong Gyun Kim
DKDeok-kee Kim
Deok-kee Kim
YCYoung Jin Choi
Young Jin Choi
This study describes the design of a flexible narrowband organic photodiode (OPDs) with a novel structure. A bulk heterojunction of poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6,6]-phenyl-C70-butyric acid methyl ester (PC 70 BM) is introduced as a photoactive layer, with an optimized thickness of 160 nm, and a MoO 3 /Ag/MoO 3 (MAM) multilayer electrode and polyimide (PI) film substrate were used. The OPD with the device architecture of PI/MAM/P3HT:PC 70 BM/Al showed narrowband photodiode performance in the 500–650 nm wavelength range. The maximum external quantum efficiency (EQE) of the OPD was 15.41% at 570 nm, which dropped to ∼0% outside the operation wavelength range. This narrowband detectivity originated from the cutoff of light at wavelengths below 500 nm by the PI substrate and photoreactivity of P3HT:PC 70 BM at wavelengths between 300 and 650 nm. Outer bending tests performed over 1000 cycles revealed that the average maximum EQE remained at ∼15%. The maximum responsivity of the OPD was calculated to be 0.07 A W −1 at 570 nm. The OPD device showed a narrow response spectrum with a full width at half maximum of 100 nm. This research suggests a new approach for the fabrication of flexible OPDs with high selectivity in color detection.